Comparison of Performance of Three Different Types of Respiratory Protection Devices
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Respiratory protection is offered to American workers in a variety of ways to guard against potential inhalation hazards. Two of the most common ways are elastomeric N95 respirators and N95 filtering-facepiece respirators. Some in the health care industry feel that surgical masks provide an acceptable level of protection in certain situations against particular hazards. This study compared the performance of these types of respiratory protection during a simulated workplace test that measured both filter penetration and face-seal leakage. A panel of 25 test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020, and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. The results of these tests produced a simulated workplace protection factor (SWPF). The geometric mean (GM) and the 5th percentile values of the SWPFs were computed by category of respiratory protection using the six overall SWPF values. The level of protection provided by each of the three respiratory protection types was compared. The GM and 5th percentile SWPF values without fit testing were used for the comparison, as surgical masks were not intended to be fit tested. The GM values were 36 for elastomeric N95 respirators, 21 for N95 filtering-facepiece respirators, and 3 for surgical masks. An analysis of variance demonstrated a statistically significant difference between all three. Elastomeric N95 respirators had the highest 5th percentile SWPF of 7. N95 filtering-facepiece respirators and surgical masks had 5th percentile SWPFs of 3 and 1, respectively. A Fisher Exact Test revealed that the 5th percentile SWPFs for all three types of respiratory protection were statistically different. In addition, both qualitative (Bitrex and saccharin) and quantitative (N95-Companion) fit testing were performed on the N95 filtering- and elastomeric-facepiece respirators. It was found that passing a fit test generally improves the protection afforded the wearer. Passing the Bitrex fit test resulted in 5th percentile SWPFs of 11.1 and 7.9 for elastomeric and filtering-facepiece respirators, respectively. After passing the saccharin tests, the elastomeric respirators provided a 5th percentile of 11.7, and the filtering-facepiece respirators provided a 5th percentile of 11.0. The 5th percentiles after passing the N95-Companion were 13.0 for the elastomeric respirators and 20.5 for the filtering-facepiece respirators. The data supports fit testing as an essential element of a complete respiratory protection program.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fitting Characteristics of Eighteen N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Campbell, D. L., Zhuang, Z., Calvert, C. A., & Jensen, P. A. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490433799 · Cited by 119 · cited 1×
“(6) , (7) Elastomeric type half-facepieces have not been assessed since the mid-1980s in NIOSH-sponsored studies.”
Self-citation
Cited by
Jayaweera, M., Perera, H., Gunawardana, B., & Manatunge, J. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109819 · Cited by 1,238
Long, Y., Hu, T., Liu, L., Chen, R., Guo, Q., Yang, L., Cheng, Y., Huang, J., & Du, L. (2020) · Journal of Evidence-Based Medicine · doi:10.1111/jebm.12381 · Cited by 339
Smith, J. D., MacDougall, C. C., Johnstone, J., Copes, R. A., Schwartz, B., & Garber, G. E. (2016) · Canadian Medical Association Journal · doi:10.1503/cmaj.150835 · Cited by 328
Surgical mask filter and fit performance
Oberg, T., & Brosseau, L. M. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.07.008 · Cited by 310
“However, no significant difference in antibody prevalence was found between surgeons wearing masks versus those who occasionally or never wore surgical masks.26 Surgical masks were not effective at reducing internal deposition of Technetium-99 metastable, an aerosolized radiopharmaceutic, in nuclear medicine personnel…”
MethodResultInfluentialMacIntyre, C. R., Wang, Q., Cauchemez, S., Seale, H., Dwyer, D. E., Yang, P., Shi, W., Gao, Z., Pang, X., Zhang, Y., et al. (2011) · Influenza and Other Respiratory Viruses · doi:10.1111/j.1750-2659.2011.00198.x · Cited by 257
Metadata
- Authors
- Lawrence, R. B., Duling, M. G., Calvert, C. A., & Coffey, C. C.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2006-09
- Volume
- 3
- Issue
- 9
- Pages
- 465-474
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2059742218
- Cited by
- 127
- References
- 1
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Performance of Three Different Types of Respiratory Protection Devices. https://app.cochat.ai/papers/10.1080/15459620600829211
- The paper
- Lawrence, R. B., Duling, M. G., Calvert, C. A., & Coffey, C. C. (2006). Comparison of Performance of Three Different Types of Respiratory Protection Devices. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459620600829211
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.