Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators
The DOI matches its Crossref record, with a small difference in title or year; 17 of the 17 references it cites were found in a registry or an index.
Abstract
While there have been a number of studies on the effect of leak site and shape on the magnitude of measured leakage through respirator face seals, there have been very few studies to identify the location and size of these leaks. In a previous study we used a method of identifying the location and shape of respirator leaks on a half-mask respirator by the deposition of a fluorescent tracer during a fit test, and testing for their association with facial dimensions. The purpose of this study was to apply that methodology to conduct multiple fit tests to determine if gender, respirator brand, repeated fit tests, and test exercises affected the location and shape of face seal leak sites. Categorical analysis found that none of these factors had a significant effect on the location and shape of leaks. General linear model analysis found some significant effects of the study factors on leaks, but facial dimensions had a greater effect, and there were significant differences between facial dimensions of subjects with a leak and those without. Significant differences in leak site distributions between this and the previous study may have been due to differences in facial dimensions and racial/ethnic composition. Twice as many diffuse leaks as point leaks were observed in both studies, indicating that slit-like leaks would be most appropriate on mannequins used in laboratory respirator leakage studies, and in respirator flow and penetration models. That the study factors had no significant effects in the categorical analysis, significant effects for facial dimensions were found in the linear analysis, and leak site distribution differences between this and our previous study may have been affected by differences in facial dimensions, indicate that, in addition to size, the shape of an individual's face may be an important determinant of leak sites on a half-mask respirator. This would have implications for the design of respirator facepieces and in the selection of respirators for individual wearers.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Some degree of leakage is expected around the edges of surgical and cloth masks in particular; poor mask fit and improper usage can further increase mask bypass, leading to a significant decrease in effectiveness [15,16,17].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [15]
Citations
Cites
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
Handbook of Parametric and Nonparametric Statistical Procedures
Sheskin, D. J. (1996) · CRC Press eBooks · doi:10.4324/9780203489536 · Cited by 910
An aerosol generator of high stability
LIU, B. Y. H., & LEE, K. W. (1975) · American Industrial Hygiene Association Journal · doi:10.1080/0002889758507357 · Cited by 218
New respirator fit test panels representing the current U.S. civilian work force
Zhuang, Z., Bradtmiller, B., & Shaffer, R. E. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701497538 · Cited by 187 · cited 4×
“were within the National Institute for Occupational Safety and Health (NIOSH) Fit Test Panel(17) indicating that this group was representative of a U.”
BackgroundMethodInfluentialThe National Institute for Occupational Safety and Health (NIOSH)
(2015) · Choice Reviews Online · doi:10.5860/choice.188912 · Cited by 169
Measurer's Handbook: U.S. Army Anthropometric Survey, 1987-1988
Clauser, C. E., Tebbetts, I., Bradtmiller, B., McConville, J. T., & Gordon, C. C. (1988) · Defense Technical Information Center (DTIC) · doi:10.21236/ada202721 · Cited by 88
OESTENSTAD, R. K., DILLION, H. K., & PERKINS, L. L. (1990) · American Industrial Hygiene Association Journal · doi:10.1080/15298669091369664 · Cited by 83
Self-citationCHARACTERISTICS OF FACE SEAL LEAKAGE IN FILTERING FACEPIECES
Chen, C. C., & Willeke, K. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360120 · Cited by 82
Performance of Dust Respirators with Facial Seal Leaks: I. Experimental
HINDS, W. C., & KRASKE, G. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385679 · Cited by 72
(2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meh097 · Cited by 50
Research works printed but not linked: 4
- Hinds W. C., 1987, Am. Ind. Hyg. J., 48, 158
- Held B. J., 1970, History of Respiratory Protective Devices in the US
- Cohen H. J., 1984, J. Int. Soc. Respir. Prot., 2, 305
- McClave J. T., 2006, Statistics,
Cited by
An upper bound on one-to-one exposure to infectious human respiratory particles
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2110117118 · Cited by 144
Lei, Z., Yang, J., Zhuang, Z., & Roberge, R. J. (2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mes085 · Cited by 97
Infrared imaging for leak detection of N95 filtering facepiece respirators: A pilot study
Roberge, R. J., Monaghan, W. D., Palmiero, A. J., Shaffer, R. E., & Bergman, M. S. (2011) · American Journal of Industrial Medicine · doi:10.1002/ajim.20970 · Cited by 51
Chopra, J., Abiakam, N., Kim, H., Metcalf, C., Worsley, P. R., & Cheong, Y. C. (2021) · BMJ Global Health · doi:10.1136/bmjgh-2021-005537 · Cited by 47
Prince, S. E., Chen, H., Tong, H., Berntsen, J. H., Masood, S. S. M. E., Zeman, K. L., Clapp, P. W., Bennett, W. D., & Samet, J. M. (2021) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-021-00337-1 · Cited by 41
He, X., Grinshpun, S. A., Reponen, T. A., Yermakov, M. V., McKay, R. T., Haruta, H., & Kimura, K. (2013) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/met014 · Cited by 39
Manikin-Based Performance Evaluation of Elastomeric Respirators Against Combustion Particles
He, X., Yermakov, M. V., Reponen, T. A., McKay, R. T., James, K., & Grinshpun, S. A. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.760063 · Cited by 38
Schmitt, J., & Wang, J. (2022) · Indoor Air · doi:10.1111/ina.13127 · Cited by 36
One size fits all?: A simulation framework for face-mask fit on population-based faces
Solano, T., Mittal, R., & Shoele, K. (2021) · PLoS ONE · doi:10.1371/journal.pone.0252143 · Cited by 35
Perimeter leakage of face masks and its effect on the mask's efficacy
Solano, T., Ni, C., Mittal, R., & Shoele, K. (2022) · Physics of Fluids · doi:10.1063/5.0086320 · Cited by 33
Inspiratory leakage flow fraction for surgical masks with varying gaps and filter materials
Xi, J., Barari, K., Si, X. A., Jamalabadi, M. Y. A., Park, J. H., & Rein, M. (2022) · Physics of Fluids · doi:10.1063/5.0090356 · Cited by 29
Overview of tight fit and infection prevention benefits of respirators (filtering face pieces)
Knobloch, J. K. ‐., Franke, G., Knobloch, M. J., Knobling, B., & Kampf, G. (2023) · Journal of Hospital Infection · doi:10.1016/j.jhin.2023.01.009 · Cited by 27
Respiratory Mask Selection and Leakage Detection System Based on Canny Edge Detection Operator
Ingle, M. A., & Talmale, G. R. (2016) · Procedia Computer Science · doi:10.1016/j.procs.2016.02.064 · Cited by 27
Evaluation of the Benefit of the User Seal Check on N95 Filtering Facepiece Respirator Fit
Viscusi, D. J., Bergman, M. S., Zhuang, Z., & Shaffer, R. E. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.683757 · Cited by 25
Bridge the gap: correlate face mask leakage and facial features with 3D morphable face models
Wang, T.-K., Solano, T., & Shoele, K. (2021) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-021-00399-1 · Cited by 19
Hariharan, P., Sharma, N., Guha, S., Banerjee, R. K., D’Souza, G. A., & Myers, M. R. (2021) · Scientific Reports · doi:10.1038/s41598-021-89604-7 · Cited by 19
Milosevic, M., Biswas, R. K., Innes, L., Ng, M., Darendeliler, A. M., Wong, A., & Denney‐Wilson, E. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2021.12.016 · Cited by 16
Rodríguez, A. A., Escanilla, D. E., Caroca, L. A., Albornoz, C. E., Marshall, P. A., Molenbroek, J. F. M., & Castellucci, H. I. (2020) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2020.103015 · Cited by 16
Lei, Z., Ji, X., Li, N., Yang, J., Zhuang, Z., & Rottach, D. R. (2014) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meu064 · Cited by 15
Wagner, J., Macher, J. M., Chen, W., & Kumagai, K. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192315555 · Cited by 14
Zhu, J., He, X., Guffey, S. E., Wang, L., Wang, H., & Cheng, J. (2019) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxz086 · Cited by 13
Balkhyour, M. A. (2013) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph10010347 · Cited by 13
He, F., Wu, J., Li, Y., Fu, M., He, S., & Weng, W. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112241 · Cited by 12
Chakladar, A., Jones, C. G., Siu, J., Hassan-Ibrahim, M. O., & Khan, M. A. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2021.02.006 · Cited by 12
Cho, K. J., Turkevich, L. A., Miller, M. A., McKay, R. T., Grinshpun, S. A., Ha, K., & Reponen, T. A. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.752321 · Cited by 8
Yu, M., Griffin, L., Durfee, W. K., & Arnold, S. F. (2024) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxae005 · Cited by 8
Teng, G., Shi, G., Zhu, J., & Zhao, C. (2023) · Scientific Reports · doi:10.1038/s41598-023-39411-z · Cited by 8
Si, X. A., Xi, J. S., Talaat, M., Park, J. H., Nagarajan, R., Rein, M., & Xi, J. (2024) · Fluids · doi:10.3390/fluids9070166 · Cited by 7
Experimental Measurement of the Size of Gaps Required to Compromise Fit of an N95 Respirator
O’Kelly, E., Arora, A., Pirog, S., Ward, J., & Clarkson, P. J. (2022) · Disaster Medicine and Public Health Preparedness · doi:10.1017/dmp.2022.23 · Cited by 6
The Spread of Exhaled Air and Aerosols during Physical Exercise
Alsaad, H., Schälte, G., Schneeweiß, M., Becher, L., Pollack, M., Gena, A. W., Schweiker, M., Hartmann, M., Voelker, C., Rossaint, R., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12041300 · Cited by 6
Evaluation of Sampling Probes for Fit Testing N95 Filtering Facepiece Respirators
Bergman, M. S., Viscusi, D. J., Zhuang, Z., & Newcomb, W. E. (2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mes091 · Cited by 6
Carter, L. N., Reed, C. A., Morrell, A. P., Fong, A. K. H., Chowdhury, R., Miller, E., Alberini, F., Khambay, B., Anand, S., Grover, L. M., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-00341-3 · Cited by 6
Tu, J., Liu, F., Wang, K., Mao, Y., Qi, Q., & Zhang, J. (2024) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2023.2268727 · Cited by 5
Investigation of the Role of Face Shape on the Flow Dynamics and Effectiveness of Face Masks
Solano, T., & Shoele, K. (2022) · Fluids · doi:10.3390/fluids7060209 · Cited by 5
Tsuji, M., Hori, H., Koriyama, C., Tanaka, R., Isse, T., Ishihara, Y., Ishizuka, T., Hasegawa, W., Goto, M., Yatera, K., et al. (2023) · Journal of Occupational Health · doi:10.1002/1348-9585.12399 · Cited by 5
Three-Dimensional Facial Parameters and Principal Component Scores: Association With Respirator Fit
Groce, D. W., Guffey, S. E., Viscusi, D. J., Lynch, S., Benson, S., & Zhuang, Z. (2010) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.167154 · Cited by 5
Fu, L., Guo, J., Zhang, Y., Jing, X., Lu, L., Wang, Y., Jiang, R., & Liu, L. (2024) · Building Simulation · doi:10.1007/s12273-024-1144-3 · Cited by 4
Which alternative well-fit masks can be used in medical procedures?
Thapthim-on, M., Chaiear, N., & Mitsungnern, T. (2023) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2023.11.023 · Cited by 3
Face-masks save us from SARS-CoV-2 transmissionPreprint
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.00375 · Cited by 2
Study on the fit of nonwoven face masks on different face shapes
Chu, C. K., Wu, H. C., Kuo, M. C., & Chan, S.-Y. (2024) · Journal of the Textile Institute · doi:10.1080/00405000.2024.2324506 · Cited by 2
Fit prediction for filtering facepiece respirator using 3D face shape
Yu, M., & Griffin, L. (2025) · Applied Ergonomics · doi:10.1016/j.apergo.2025.104667 · Cited by 2
Yu, M., & Griffin, L. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4837907 · Cited by 2
The facial measurements in health workers at Dr. Sardjito General Hospital, Yogyakarta
Aliya, N. H., Rahmawati, N. T., Hastuti, J., & Febriana, S. A. (2023) · Journal of the Medical Sciences (Berkala Ilmu Kedokteran) · doi:10.19106/jmedsci005502202306 · Cited by 2
Chaiear, N. (2023) · Asia-Pacific Journal of Science and Technology · doi:10.14456/apst.2023.28 · Cited by 2
Arnoldsson, K. C., Danielsson, S., & Thunéll, M. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1117616 · Cited by 2
Zaman, S., Seligman, H., Lloyd, F. H., Patel, K. T., Chappell, D., O’Hare, D., Cole, G. D., Francis, D. P., Petraco, R., & Linton, N. (2021) · Clinical Medicine · doi:10.7861/clinmed.2020-0982 · Cited by 2
Tjolleng, A., Chang, J., Park, J., & Kihyo, J. (2023) · International journal of industrial engineering · Cited by 2
Kumar, B., Patel, P., Aggarwal, S. G., Tawale, J. S., Singh, K., Malik, A., Soni, D., Kumar, S., Moona, G., Ojha, V. N., et al. (2025) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2025.2544750 · Cited by 1
Simulation Studies Related to COVID-19 Pandemic
Bhavya, E. V., & Choudhury, B. (2022) · Materials horizons · doi:10.1007/978-981-16-4372-9_9 · Cited by 1
Okrasa, M., Leszczyńska, M., Sałasińska, K., Szczepkowski, L., Kozikowski, P., Adamus-Włodarczyk, A., Walczak, Z., & Ryszkowska, J. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2408943 · Cited by 1
Total Inward Leakage (TIL) Testing of Anti-yellow Sand and Quarantine Masks Using NaCl Aerosol
Jung, H., Lee, S., Lee, J., Kim, J., Tsai, P., & Yoon*, C. (2014) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.166893 · Cited by 1
Hosseinabadi, M. B., Yu, M., Petersen, A. J., Griffin, L., Durfee, W. K., & Arnold, S. F. (2026) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxag050
Silva, E., Castellucci, H. I., Camberes, R., Lira, J., Marabolí, J., Viviani, C., Molenbroek, J. F. M., Huysmans, T., Rodríguez, A., Caroca, L. A., et al. (2025) · Applied Ergonomics · doi:10.1016/j.apergo.2025.104551
Simulation-based assessment for N95 filtering facepiece respirator
Lei, Z. (2014) · ThinkTech (Texas Tech University)
Evaluation of N95 Respirator Fit Changes in Nurses Working in High-risk Airborne Infection Units
Han, S.-H., Cha, K., Lee, H., & Choung, Y. (2024) · Korean Journal of Healthcare-Associated Infection Control and Prevention · doi:10.14192/kjicp.2024.29.2.137
Silva, V. D. E., Abele, M., Bercovitz, I., & Ferguson, S. (2025) · Workplace Health & Safety · doi:10.1177/21650799241230039
Free Energy of Hydration of Drugs - Molecular Descriptors for Solvation Limited SolubilityPreprint
Wassvik, C. M., Holmén, A., & Artursson, P. (2006)
Cowan, D. M., Benson, S. M., Cheng, T. J., Hecht, S., Boulos, N. M., & Henshaw, J. L. (2016) · Archives of Environmental & Occupational Health · doi:10.1080/19338244.2016.1205546
View or download the full issue
Sciences, J. O. T. M. (2023) · Jurnal Perlindungan Tanaman Indonesia (Universitas Gadjah Mada)
He, X. (2013) · OhioLink ETD Center (Ohio Library and Information Network)
Metadata
- Authors
- Oestenstad, R. K., & Bartolucci, A. A.
- Affiliations
- University of Alabama at Birmingham (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2010-04-08
- Volume
- 7
- Issue
- 6
- Pages
- 332-341
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2053309387
- Cited by
- 54
- References
- 17
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 8 · 2023: 7 · 2022: 7 · 2021: 11 · 2020: 1 · 2019: 1 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 4
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (1K01OH00085)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- half-mask respirators, facial dimensions, respirator fit testing, fluorescent tracers, gender differences, respirator selection
- MeSH terms
- Adult, Anthropometry, Equipment Design, Face, Female, Humans, Male, Middle Aged, Respiratory Protective Devices, Sex Factors, Equipment Failure Analysis, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.