Abstract

Faceseal leaks on one brand of half-mask respirator worn by 73 human subjects were identified by deposition of a fluorescent tracer aerosol during a standard quantitative fit test. The identified leaks were categorized according to their location and shape. It was found that about 89% of all observed leaks occurred at the nose or chin or were multiple leaks which included these sites. Fit factors for these types of leaks were significantly lower than for other types of leaks. About 73% of all leaks approximated the shape of a slit rather than a round orifice, and the prevalence of these leaks was affected by gender. Significant association of facial dimensions and leak sites were found. Most of these were attributed to differences in gender, and only a very small percentage were for the facial dimensions used to define the Los Alamos respirator test panel. Significant correlation of facial dimensions and fit factor were found for only three facial dimensions; none of which are used to define the test panel. Evidence of airflow streamlining within the facepiece was observed on 22% of the subjects. Results of this study indicate that respirator leakage is strongly affected by nose and chin leaks, that gender is a factor in how a respirator fits, and that consideration should be given to including nasal dimensions when defining a respirator test panel and selecting a respirator for an individual wearer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/15298669091369664

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 83

Metadata

Authors
OESTENSTAD, R. K., DILLION, H. K., & PERKINS, L. L.
Venue
American Industrial Hygiene Association Journal
Published
1990-05
Volume
51
Issue
5
Pages
285-290
ISSN
0002-8894 (ISSN-L)
OpenAlex
W2062617158
Cited by
83
References
0
FWCI
4.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Distribution of Faceseal Leak Sites on a Half-Mask Respirator and Their Association with Facial Dimensions. https://app.cochat.ai/papers/10.1080/15298669091369664
The paper
OESTENSTAD, R. K., DILLION, H. K., & PERKINS, L. L. (1990). Distribution of Faceseal Leak Sites on a Half-Mask Respirator and Their Association with Facial Dimensions. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15298669091369664

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.