Performance of two respiratory protective devices used by home-attending health care workers (a pilot study)
Open accessAbstract
Objectives: This pilot study aimed at determining the Workplace Protection Factor (WPF) for respiratory protective devices widely used by health care workers to reduce exposure to potentially hazardous aerosols when attending patients in their homes. Two devices were tested, an N95 filtering facepiece respirator (FFR) and a surgical mask (SM).Methods: Three home-attending health care workers were recruited, medically cleared and fit tested. At the workplace, the aerosol concentrations outside (Cout) and inside (Cin) of the tested respiratory protective device worn by a subject were measured using two simultaneously operating P-Trak condensation particle counters within the particle size range of approximately 20–1,000 nm. Real-time and integrated (time-weighted average, TWA) values of WPF = Cout/Cin were determined.Results: This pilot study demonstrated that the WPF of the tested N95 FFR consistently exceeded that of the SM. The WPFTWA(C) values calculated for the entire test time (based on the TWA aerosol concentration values) ranged from 29 to 40 and 2 to 9, respectively. In all cases, the N95 FFR provided protection above the Occupational Safety and Health Administration's (OSHA) assigned protection factor of 10, whereas the SM often offered little or essentially no protection against the measured sub-micrometer aerosol particles. For both devices, the protection level was found to depend on activity. For example, the WPFTWA(C) for one subject wearing the N95 FFR was 56 during normal activity but fell almost 70% during tracheal suctioning. It is explicable considering that different procedures implemented by health care workers in homes generate particles of different sizes and require different body movements; both factors are anticipated to affect the WPF.Conclusions: Wearing an N95-certified respirator helps significantly reduce the aerosol inhalation exposure of home-attending health care workers. An SM offers much lower protection. The WPF depends on several factors, including, but not limited to, the health care worker's activity and/or body movements; the WPF varies from one worker to another.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
N95 FFRs are employed as personal protective equipment (PPE) and they provide a high level of protection for filtering facepiece masks that cover only the nose and mouth.
“N95 FFR are employed as personal protective equipment (PPE) and they provide a high level of protection for filtering facepiece masks that cover only the nose and mouth (as opposed to full and half-face respirators constructed from elastomeric materials) [3, 58–74].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [65]
The Introduction describes N95 filtering facepiece respirators as widely used respiratory protection, and the Conclusions report significantly better protection than a surgical mask in this pilot study (page numbers unavailable). The copy does not address the claim that these devices cover only the nose and mouth or contrast them with elastomeric full- and half-face respirators; its protection finding is limited to one N95 model tested during home visits. (LLM, conf=0.85)
Experimental — accuracy not yet measuredThe Quality Factor (QF) is commonly used to compare the performance of materials used to filter particulates under similar experimental conditions.
“The Quality Factor (QF) is commonly used to compare the performance of materials used to filter particulates under similar experimental conditions [62–81];”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [65]
The Introduction and Materials and Methods describe Workplace Protection Factor (WPF), calculated from aerosol concentrations inside and outside a worn respirator. Searches for Quality Factor (QF) and comparisons of particulate-filter materials found no passage addressing the claim; the indexed copy provides no page numbers. (LLM, conf=0.75)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353 · see citing works
Self-citationBałazy, A., Toivola, M., Reponen, T. A., Podgórski, A., Zimmer, A. T., & Grinshpun, S. A. (2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mei058 · Cited by 237 · see citing works
Self-citationPrevalence of Respiratory Protective Devices in U.S. Health Care Facilities
Wizner, K., Stradtman, L. R., Novak, D. A., & Shaffer, R. E. (2016) · Workplace Health & Safety · doi:10.1177/2165079916657108 · Cited by 54 · see citing works
Gao, S., Koehler, R. H., Yermakov, M., & Grinshpun, S. A. (2016) · Annals of Occupational Hygiene · doi:10.1093/annhyg/mew006 · Cited by 46 · see citing works
Self-citationReal-Time Fit of a Respirator during Simulated Health Care Tasks
Hauge, J., Roe, M., Brosseau, L. M., & Colton, C. E. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.711699 · Cited by 26 · see citing works
Kim, H., Jung-Eun, B. A. E. K., Seo, H., Lee, J.-E., Myong, J., Lee, S., & Lee, J. (2015) · Industrial Health · doi:10.2486/indhealth.2014-0259 · Cited by 19 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [8]“Respiratory protection,” Code of Federal Regulations Title 29, Part 1910.134 1998 pp. 412– 437.
Cited by
Sorted by citations
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621 · see citing works
Ippolito, M., Vitale, F., Accurso, G., Iozzo, P., Gregoretti, C., Giarratano, A., & Cortegiani, A. (2020) · Pulmonology · doi:10.1016/j.pulmoe.2020.04.009 · Cited by 181 · see citing works
Facial protection for healthcare workers during pandemics: a scoping review
Godoy, L. R. G., Jones, A. E., Anderson, T. N., Fisher, C., Seeley, K. M. L., Beeson, E. A., Zane, H. K., Peterson, J. W., & Sullivan, P. D. (2020) · BMJ Global Health · doi:10.1136/bmjgh-2020-002553 · Cited by 144 · see citing works
Duncan, S., Bodurtha, P., & Naqvi, S. (2021) · PLOS ONE · doi:10.1371/journal.pone.0258191 · Cited by 75 · see citing works
Biney, I. N., Ari, A., Barjaktarević, I., Carlin, B. W., Christiani, D. C., Cochran, L. W., Drummond, M., Johnson, K., Kealing, D., Kuehl, P. J., et al. (2023) · CHEST Journal · doi:10.1016/j.chest.2023.11.013 · Cited by 25 · see citing works
Fugitive aerosols in the intensive care unit: a narrative review
O’Toole, C., Joyce, M., McGrath, J. A., O’Sullivan, A., Byrne, M. A., & MacLoughlin, R. J. (2021) · Annals of Translational Medicine · doi:10.21037/atm-20-2280 · Cited by 23 · see citing works
Ollier, K., Leppänen, M., Wu, B., Yermakov, M. V., Newman, N. C., Reponen, T. A., & Grinshpun, S. A. (2018) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2018.10.0366 · Cited by 16 · see citing works
Self-citationExposure of home-attending healthcare workers to aerosolized medications (simulation study)
Elmashae, Y., Yermakov, M. V., Frank, E. A., Benjamin, M., Maier, A., Newman, N. C., Reponen, T. A., & Grinshpun, S. A. (2019) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2019.04.006 · Cited by 12 · see citing works
Self-citationLi, J., Qiu, Y., Zhang, Y., Gong, X., He, Y., Yue, P., Zheng, X., Liu, L., Liao, H., Zhou, K., et al. (2021) · Medicine · doi:10.1097/md.0000000000027026 · Cited by 10 · see citing works
Unterwurzacher, V., Bruck, S., Biedermann, M., Pogner, C., Konlechner, A., Tondl, G., Berger, H., Pfeifer, C., Strauss, J., Gorfer, M., et al. (2021) · Aerosol Science and Engineering · doi:10.1007/s41810-021-00110-9 · Cited by 8 · see citing works
Optimizing Respirator Fit Testing for Health Care Personnel
Harber, P. I. (2022) · CHEST Journal · doi:10.1016/j.chest.2022.02.043 · Cited by 1 · see citing works
Breathing Patterns During Job-Related Tasks for Home Healthcare Workers Influencing Aerosol Exposure
Bellacov, R. L., Davis, K. G., Wang, J., & Kotowski, S. (2025) · Home Health Care Management & Practice · doi:10.1177/10848223251352497
- Authors
- Elmashae, R. B. Y., Grinshpun, S. A., Reponen, T., Yermakov, M., & Riddle, R.
- Affiliations
- University of Cincinnati (US)
- Cincinnati Children's Hospital Medical Center (US)
- Corresponding author
- Grinshpun, Sergey A.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2017-08-24
- Volume
- 14
- Issue
- 9
- Pages
- D145-D149
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- PMC
- PMC6748322
- OpenAlex
- W2624648757
- Cited by
- 12
- References
- 6
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 1 · 2021: 4 · 2020: 3 · 2019: 1 · 2018: 1
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute for Occupational Safety and Health (T42-OH008432)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Health Sciences › Health Professions › Occupational Therapy › Occupational Health and Safety in Workplaces
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Keywords
- workplace protection factor, N95 respirators, surgical masks, endotracheal suctioning, personal protective equipment, aerosol concentration measurement, condensation particle counter
- MeSH terms
- Aerosols, Air Pollutants, Occupational, Female, Filtration, Health Personnel, Home Care Services, Humans, Masks, Pilot Projects, Respiratory Protective Devices, Occupational Exposure, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review