Direct measurement of light and heavy antibody chains using ion mobility and middle-down mass spectrometry
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The analysis of monoclonal antibodies (mAbs) by a middle-down mass spectrometry (MS) approach is a growing field that attracts the attention of many researchers and biopharmaceutical companies. Usually, liquid fractionation techniques are used to separate mAbs polypeptides chains before MS analysis. Gas-phase fractionation techniques such as high-field asymmetric waveform ion mobility spectrometry (FAIMS) can replace liquid-based separations and reduce both analysis time and cost. Here, we present a rapid FAIMS tandem MS method capable of characterizing the polypeptide sequence of mAbs light and heavy chains in an unprecedented, easy, and fast fashion. This new method uses commercially available instruments and takes ~24 min, which is 40-60% faster than regular liquid chromatography-MS/MS analysis, to acquire fragmentation data using different dissociation methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000 · cited 1×
“0.(33) Fragmentation peak fitting and annotation were performed with TDValidator v1.”
MethodFornelli, L., Srzentić, K., Huguet, R., Mullen, C., Sharma, S., Zabrouskov, V., Fellers, R. T., Durbin, K. R., Compton, P. D., & Kelleher, N. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00984 · Cited by 150 · cited 1×
“Each LC-MS/MS run takes several minutes, only one fragmentation method is used per run generally, and multiple injections are needed to maximize sequence coverage.(14) Furthermore, liquid chromatography instruments add expense, with elevated operational costs depending on the columns and extent of method development r…”
BackgroundSelf-citationJin, Y., Lin, Z., Xu, Q., Fu, C., Zhang, Z., Zhang, Q., Pritts, W. A., & Ge, Y. (2019) · mAbs · doi:10.1080/19420862.2018.1525253 · Cited by 68
Cited by
Roberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Enhancing Top-Down Proteomics of Brain Tissue with FAIMS
Fulcher, J. M., Makaju, A., Moore, R. J., Zhou, M., Bennett, D. A., De Jager, P. L., Qian, W.-J., Paša-Tolić, L., & Petyuk, V. A. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00049 · Cited by 68
Enhancing top-down proteomics of brain tissue with FAIMS
(2021) · doi:10.1101/2021.01.18.427216 · Cited by 68
Larson, E. J., Zhu, Y., Wu, Z., Chen, B., Zhang, Z., Zhou, S., Han, L., Zhang, Q., & Ge, Y. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03152 · Cited by 21
Metadata
- Authors
- Melani, R. D., Srzentić, K., Gerbasi, V. R., McGee, J. P., Huguet, R., Fornelli, L., & Kelleher, N. L.
- Venue
- mAbs
- Publisher
- Informa UK Limited
- Published
- 2019-10-13
- Volume
- 11
- Issue
- 8
- Pages
- 1351-1357
- ISSN
- 1942-0862 (ISSN-L)
- 1942-0870
- OpenAlex
- W2979605358
- Cited by
- 37
- References
- 3
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.