Cited by 21Mass Spectrometry Techniques and ApplicationsMonoclonal and Polyclonal Antibodies ResearchBiosimilars and Bioanalytical Methods

Rapid Analysis of Reduced Antibody Drug Conjugate by Online LC-MS/MS with Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Open access
Larson, Eli J., Zhu, Yanlong, Wu, Zhijie, Chen, Bifan, Zhang, Zhaorui, Zhou, Shiyue, Han, Linjie, Zhang, Qunying +1 more·2020·Analytical Chemistry

Abstract

Antibody drug conjugates (ADCs), which harness the high targeting specificity of monoclonal antibodies (mAb) with the potency of small molecule therapeutics, are one of the fastest growing pharmaceutical classes. Nevertheless, ADC conjugation techniques and processes may introduce intrinsic heterogeneity including primary sequence variants, varied drug-to-antibody ratio (DAR) species, and drug positional isomers, which must be monitored to ensure the safety and efficacy of ADCs. Liquid chromatography coupled to mass spectrometry (LC-MS) is a powerful tool for characterization of ADCs. However, the conventional bottom-up MS analysis workflows require an enzymatic digestion step which can be time consuming and may introduce artifactual modifications. Herein, we develop an online LC-MS/MS method for rapid analysis of reduced ADCs without digestion, enabling determination of DAR, characterization of the primary sequence, and localization of the drug conjugation site of the ADC using high-resolution Fourier transform ion cyclotron resonance (FTICR) MS. Specifically, a model cysteine-linked ADC was reduced to generate six unique subunits: light chain (Lc) without drug (Lc0), Lc with 1 drug (Lc1), heavy chain (Hc) without drug (Hc0), and Hc with 1-3 drugs (Hc1-3, respectively). A concurrent reduction strategy is applied to assess ADC subunits in both the partially reduced (intrachain disulfide bonds remain intact) and fully reduced (all disulfide bonds are cleaved) forms. The entire procedure including the sample preparation and LC-MS/MS takes less than 55 min, enabling rapid multiattribute analysis of ADCs.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.0c03152

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Larson, E. J., Zhu, Y., Wu, Z., Chen, B., Zhang, Z., Zhou, S., Han, L., Zhang, Q., & Ge, Y.
Affiliations
  • University of Wisconsin–Madison (US)
  • AbbVie (United States) (US)
Corresponding author
Ge, Ying
Venue
Analytical Chemistry
Published
2020-10-27
Volume
92
Issue
22
Pages
15096-15103
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3095006435
Cited by
21
References
35
Citations by year
2026: 2 · 2025: 7 · 2024: 5 · 2023: 2 · 2022: 2 · 2021: 2 · 2020: 1
FWCI
0.67
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • AbbVie
  • National Institute of General Medical Sciences (GM125085)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Monoclonal and Polyclonal Antibodies Research
  • Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
Keywords
antibody-drug conjugates, drug-to-antibody ratio, disulfide bond cleavage, monoclonal antibodies, FT-ICR mass spectrometry, LC-MS/MS
MeSH terms
Chromatography, Liquid, Fourier Analysis, Isomerism, Time Factors, Cyclotrons, Immunoconjugates, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review