Acceptability and usability of an ambulatory health monitoring system for use by military personnel

Tharion, William J., Buller, Mark J., Potter, Adam W., Karis, Anthony J., Goetz, Victoria, Hoyt, Reed W.·2013·IIE Transactions on Occupational Ergonomics and Human Factors

Abstract

OCCUPATIONAL APPLICATIONS A physiological status monitoring system was evaluated for use by soldiers in the field. Two different designs were evaluated, with the design based on previous human factors evaluations proven to be more comfortable and acceptable for use. This study demonstrated that the advanced design of the EQ-02 physiological status monitoring system met dismounted soldier needs. Furthermore, this study validated the use of a usability evaluation in the successful design/advancement of a physiological status monitoring system. TECHNICAL ABSTRACT Background: Previous research has shown that the form factor of a physiological status monitoring system, the Equivital™ EQ-01 (Hidalgo Ltd., Cambridge, UK) had problems associated with comfort and usability of the system for soldiers. Previous data gathered was used to guide improvements in the physiological status monitoring system. Purpose: Assess whether the previous feedback from usability evaluations helped guide improvements in comfort, acceptability, and usability of a physiological status monitoring system for dismounted soldiers. Improvements to the EQ-01 system were incorporated into the next-generation EQ-02 (Hidalgo Ltd., Cambridge, UK) system. Methods: Thirty-nine infantry dismounted soldiers were randomly assigned to wear either an EQ-01 or EQ-02 system while performing standard military field training. They filled out a survey on fit, comfort, irritation to the body, impact on military performance, and acceptability. They then wore the other system and filled out the same survey. Results: The Equivital™ EQ-02 system was superior in terms of fit (51% better in overall fit), ease of donning (10% easier), comfort (45% more comfortable), impact on military performance (45% less impact), impact on the body (17% less impact), and acceptability (32% more acceptable). All these measures are subjective self-report ratings. Conclusions: A human factors engineering approach provided an effective means of guiding improvements and the production of a physiological status monitoring system that dismounted soldiers were more likely to accept and wear.

Integrity signals

Registry

Crossref · 10.1080/21577323.2013.838195

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Tharion, W. J., Buller, M. J., Potter, A. W., Karis, A. J., Goetz, V., & Hoyt, R. W.
Affiliations
U.S. Army Research Institute of Environmental Medicine (US)
Venue
IIE Transactions on Occupational Ergonomics and Human Factors
Published
2013-10
Volume
1
Issue
4
Pages
203-214
ISSN
  • 2157-7323 (ISSN-L)
  • 2157-7331
OpenAlex
W2020409825
Cited by
27
References
15
Citations by year
2025: 3 · 2024: 2 · 2023: 3 · 2021: 3 · 2020: 3 · 2019: 2 · 2018: 4 · 2017: 1 · 2016: 3 · 2015: 1 · 2014: 1 · 2013: 1
FWCI
6.29
Type
journal article
Language
en
Open access
closed
Locations
IIE Transactions on Occupational Ergonomics and Human Factors (publishedVersion)
Funders
U.S. Department of Defense
Topics
  • Health Sciences › Health Professions › Occupational Therapy › Occupational Health and Performance
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Computer Science › Human-Computer Interaction › Usability and User Interface Design
Keywords
military personnel, dismounted soldiers, wearable sensors, usability evaluation, acceptability, comfort, form factors, human factors engineering, military field training

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review