A review of biosensor for environmental monitoring: principle, application, and corresponding achievement of sustainable development goals
Open accessThe DOI matches its Crossref record; 135 of the 135 references it cites were found in a registry or an index.
Abstract
Human health/socioeconomic development is closely correlated to environmental pollution, highlighting the need to monitor contaminants in the real environment with reliable devices such as biosensors. Recently, variety of biosensors gained high attention and employed as in-situ application, in real-time, and cost-effective analytical tools for healthy environment. For continuous environmental monitoring, it is necessary for portable, cost-effective, quick, and flexible biosensing devices. These benefits of the biosensor strategy are related to the Sustainable Development Goals (SDGs) established by the United Nations (UN), especially with reference to clean water and sources of energy. However, the relationship between SDGs and biosensor application for environmental monitoring is not well understood. In addition, some limitations and challenges might hinder the biosensor application on environmental monitoring. Herein, we reviewed the different types of biosensors, principle and applications, and their correlation with SDG 6, 12, 13, 14, and 15 as a reference for related authorities and administrators to consider. In this review, biosensors for different pollutants such as heavy metals and organics were documented. The present study highlights the application of biosensor for achieving SDGs. Current advantages and future research aspects are summarized in this paper.Abbreviations: ATP: Adenosine triphosphate; BOD: Biological oxygen demand; COD: Chemical oxygen demand; Cu-TCPP: Cu-porphyrin; DNA: Deoxyribonucleic acid; EDCs: Endocrine disrupting chemicals; EPA: U.S. Environmental Protection Agency; Fc-HPNs: Ferrocene (Fc)-based hollow polymeric nanospheres; Fe3O4@3D-GO: Fe3O4@three-dimensional graphene oxide; GC: Gas chromatography; GCE: Glassy carbon electrode; GFP: Green fluorescent protein; GHGs: Greenhouse gases; HPLC: High performance liquid chromatography; ICP-MS: Inductively coupled plasma mass spectrometry; ITO: Indium tin oxide; LAS: Linear alkylbenzene sulfonate; LIG: Laser-induced graphene; LOD: Limit of detection; ME: Magnetoelastic; MFC: Microbial fuel cell; MIP: Molecular imprinting polymers; MWCNT: Multi-walled carbon nanotube; MXC: Microbial electrochemical cell-based; NA: Nucleic acid; OBP: Odorant binding protein; OPs: Organophosphorus; PAHs: Polycyclic aromatic hydrocarbons; PBBs: Polybrominated biphenyls; PBDEs: Polybrominated diphenyl ethers; PCBs: Polychlorinated biphenyls; PGE: Polycrystalline gold electrode; photoMFC: photosynthetic MFC; POPs: Persistent organic pollutants; rGO: Reduced graphene oxide; RNA: Ribonucleic acid; SDGs: Sustainable Development Goals; SERS: Surface enhancement Raman spectrum; SPGE: Screen-printed gold electrode; SPR: Surface plasmon resonance; SWCNTs: single-walled carbon nanotubes; TCPP: Tetrakis (4-carboxyphenyl) porphyrin; TIRF: Total internal reflection fluorescence; TIRF: Total internal reflection fluorescence; TOL: Toluene-catabolic; TPHs: Total petroleum hydrocarbons; UN: United Nations; VOCs: Volatile organic compounds
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response to cadmium in higher plants
Sanità di Toppi, L., & Gabbrielli, R. (1999) · Environmental and Experimental Botany · doi:10.1016/s0098-8472(98)00058-6 · Cited by 2,252
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors
Naresh, V., & Lee, N. (2021) · Sensors · doi:10.3390/s21041109 · Cited by 2,066
Breaker, R. R., & Joyce, G. F. (1994) · Chemistry & Biology · doi:10.1016/1074-5521(94)90014-0 · Cited by 1,476 · cited 1×
“Many detection methods have been assessed using the 8–17 DNAzyme specific for lead ions [115,130,131].”
MethodMicrobial Resistance to Metals in the Environment
Bruins, M. R., Kapil, S., & Oehme, F. W. (2000) · Ecotoxicology and Environmental Safety · doi:10.1006/eesa.1999.1860 · Cited by 1,445 · cited 1×
“Expression of the resistance genes including redox transformation, active transport, and intracellular/extracellular precipitation is regulated by intracellular metal level [51].”
BackgroundVareda, J. P., Valente, A. J. M., & Durães, L. (2019) · Journal of Environmental Management · doi:10.1016/j.jenvman.2019.05.126 · Cited by 1,010 · cited 1×
“Due to their pronounced toxicity, these heavy metals are important for monitoring the environment (water, wastewater, air, solid waste, and organisms) [95,97,98].”
BackgroundBacterial resistances to toxic metal ions - a review
Silver, S. (1996) · Gene · doi:10.1016/s0378-1119(96)00323-x · Cited by 592
A review on ZnO nanostructured materials: energy, environmental and biological applications
Theerthagiri, J., Salla, S., Senthil, R. A., Nithyadharseni, P., Madankumar, A., Arunachalam, P., Maiyalagan, T., & Kim, H.-S. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab268a · Cited by 530 · cited 1×
“To further understand the bioavailability of environmental pollutants, biosensors using biological sensor to detect such pollutants have been invented, and they have features of low-cost, energy-saving, and feasibility for real-time in situ monitoring [4,5].”
BackgroundCopA: An Escherichia coli Cu(I)-translocating P-type ATPase
Rensing, C., Fan, B., Sharma, R., Mitra, B., & Rosen, B. P. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.2.652 · Cited by 516 · cited 1×
“copA is responsible for the concentration of Cu and Ag in cells [59].”
BackgroundRecent Progress in Biosensors for Environmental Monitoring: A Review
Justino, C., Duarte, A., & Rocha-Santos, T. (2017) · Sensors · doi:10.3390/s17122918 · Cited by 456
Daunert, S., Barrett, G., Feliciano, J. S., Shetty, R. S., Shrestha, S., & Smith-Spencer, W. (2000) · Chemical Reviews · doi:10.1021/cr990115p · Cited by 445 · cited 5×
“Nonspecific whole-cell biosensors are constructed mainly by stress responsive genetic regulation, such as heat shock and DNA damage responses [6].”
BackgroundMethodInfluentialThe zntA gene of Escherichia coli encodes a Zn(II)-translocating P-type ATPase
Rensing, C., Mitra, B., & Rosen, B. P. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.26.14326 · Cited by 419 · cited 1×
“zntA accounts for the removal of intracellular Zn and responds to Cd and Pb [57,58].”
BackgroundRecent progress and growth in biosensors technology: A critical review
Chadha, U., Bhardwaj, P., Agarwal, R., Rawat, P., Agarwal, R., Gupta, I., Panjwani, M., Singh, S., Ahuja, C., Selvaraj, S. K., et al. (2022) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2022.02.010 · Cited by 388 · cited 1×
“Currently, biosensors targeting heavy metals, pesticides, or pharmaceuticals show the advantages of biosensor such as portability, ease of use, and saving time [18,19].”
BackgroundTheerthagiri, J., Lee, S. J., Karuppasamy, K., Arulmani, S., Veeralakshmi, S., Ashokkumar, M., & Choi, M. Y. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.125245 · Cited by 364
Nucifora, G., Chu, L., Misra, T. K., & Silver, S. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.10.3544 · Cited by 359 · cited 2×
“Cell-based biosensors for cadmium and mercury were able to detect other metal ions, such as copper, zinc, or lead, which reduces their selectivity [6,54].”
BackgroundMethodRecent advances in biosensor techniques for environmental monitoring
Rogers, K. R. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.067 · Cited by 358 · cited 1×
“Biosensor is an analytical strategy for pollutants based on biotechnology, and consists of elements for signal transducer producing detectable or quantifiable signals when sensing pollutants [6,13].”
BackgroundOutten, F. W., Outten, C. E., Hale, J., & O'Halloran, T. V. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m006508200 · Cited by 339 · cited 1×
“Regulatory proteins of zntA and copA belong to the MerR homologue, thereby making them responsible for Hg [60,61].”
BackgroundRecent advances in DNA-based electrochemical biosensors for heavy metal ion detection: A review
Saidur, M. R., Aziz, A. R. A., & Basirun, W. J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.039 · Cited by 339 · cited 3×
“DNA biosensors based on electrochemical transduction, constitute an sensitive technique and affordable method for detection and monitoring of heavy metal elements [99,138].”
BackgroundMethodThe TOL Plasmids: Determinants of the Catabolism of Toluene and the Xylenes
Assinder, S. J., & Williams, P. A. (1990) · Advances in Microbial Physiology · doi:10.1016/s0065-2911(08)60119-8 · Cited by 320 · cited 1×
“For organic pollutants, toluene and xylene can be metabolized by toluene-catabolic (TOL) plasmid in bacteria harboring those regulatory genes [42].”
BackgroundWeber, R., Watson, A., Forter, M., & Oliaei, F. (2011) · Waste Management & Research: The Journal for a Sustainable Circular Economy · doi:10.1177/0734242x10390730 · Cited by 317
Aptamer-Based Biosensors for Environmental Monitoring
McConnell, E. M., Nguyen, J., & Li, Y. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.00434 · Cited by 313 · cited 1×
“For cell-free biosensor, aptamer coupled with nanomaterials biosensors were commonly used for their good selectivity and reliability [29].”
MethodRapid and sensitive pollutant detection by induction of heat shock gene-bioluminescence gene fusions
Van Dyk, T. K., Majarian, W. R., Konstantinov, K. B., Young, R. M., Dhurjati, P. S., & LaRossa, R. A. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.5.1414-1420.1994 · Cited by 298
Biosensors for wastewater monitoring: A review
Ejeian, F., Etedali, P., Mansouri-Tehrani, H.-A., Soozanipour, A., Low, Z.-X., Asadnia, M., Taheri-Kafrani, A., & Razmjou, A. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.07.019 · Cited by 287 · cited 2×
“Wastewater discharge is the one of the source of environmental pollution, and the wastewater quality monitoring could be also achieved by the biosensors [145].”
BackgroundResultSmall molecular fluorescent probes for the detection of lead, cadmium and mercury ions
Chen, S.-Y., Li, Z., Li, K., & Yu, X.-Q. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213691 · Cited by 283 · cited 1×
“Environmental Protection Agency (EPA) regulations, the maximum levels of heavy metals such as Hg, Pb and Cd in drinking water are 10 nM, 72 nM and 45 nM, respectively, so these described biosensors could effectively monitor their concentrations [103,116].”
BackgroundElectrochemical DNAzyme Sensor for Lead Based on Amplification of DNA−Au Bio-Bar Codes
Shen, L., Chen, Z., Li, Y., He, S., Xie, S., Xu, X., Liang, Z., Meng, X., Li, Q., Zhu, Z., et al. (2008) · Analytical Chemistry · doi:10.1021/ac800601y · Cited by 278 · cited 1×
“[132] used DNA-Au bio-barcode based on a signal amplification assay for Pb ion detection.”
MethodAdvanced in developmental organic and inorganic nanomaterial: a review
Khalid, K., Tan, X., Mohd Zaid, H. F., Tao, Y., Lye Chew, C., Chu, D.-T., Lam, M. K., Ho, Y.-C., Lim, J. W., & Chin Wei, L. (2020) · Bioengineered · doi:10.1080/21655979.2020.1736240 · Cited by 263
Applications of whole-cell bacterial sensors in biotechnology and environmental science
Yagi, K. (2007) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0718-6 · Cited by 254 · cited 1×
“Similarly, the stress-inducible heat shock genes like hsp70 and its promoter were used in biosensors for detecting nonspecific toxicity since the heat shock protein systems will be triggered not only by heat shock but also other environmental stressors, and then induce the downstream fused signals [72,73].”
BackgroundTheerthagiri, J., Chandrasekaran, S., Salla, S., Elakkiya, V., Senthil, R. A., Nithyadharseni, P., Maiyalagan, T., Micheal, K., Ayeshamariam, A., Arasu, M. V., et al. (2018) · Journal of Solid State Chemistry · doi:10.1016/j.jssc.2018.08.006 · Cited by 249
Heitzer, A., Malachowsky, K., Thonnard, J. E., Bienkowski, P. R., White, D. C., & Sayler, G. S. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.5.1487-1494.1994 · Cited by 248
Wu, Y., Zhan, S., Wang, F., He, L., Zhi, W., & Zhou, P. (2012) · Chemical Communications · doi:10.1039/c2cc30384a · Cited by 239
Tuan Tran, H., Lin, C., Bui, X.-T., Ky Nguyen, M., Dan Thanh Cao, N., Mukhtar, H., Giang Hoang, H., Varjani, S., Hao Ngo, H., & Nghiem, L. D. (2022) · Bioresource Technology · doi:10.1016/j.biortech.2021.126249 · Cited by 237
Self-citationMicrobial fuel cell-based biosensor for online monitoring wastewater quality: A critical review
Do, M. H., Ngo, H. H., Guo, W., Chang, S. W., Nguyen, D. D., Liu, Y., Varjani, S., & Kumar, M. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.135612 · Cited by 229 · cited 3×
“Water quality monitoring such as BOD, COD, and toxicants using the MFCbased biosensors and the toxicity-based nonspecific biosensors reflects not only the toxicity in drinking water but also the extent of eutrophication [23,81].”
BackgroundMethodSelf-citationTheerthagiri, J., Senthil, R. A., Priya, A., Madhavan, J., Michael, R. J. V., & Ashokkumar, M. (2014) · RSC Adv. · doi:10.1039/c4ra04266b · Cited by 221
Investigating the Carbon Footprint of a University - The case of NTNU
Larsen, H. N., Pettersen, J., Solli, C., & Hertwich, E. G. (2013) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2011.10.007 · Cited by 218
Jayaraman, T., Arumugam Raja, S., Priya, A., Jagannathan, M., & Ashokkumar, M. (2015) · New Journal of Chemistry · doi:10.1039/c4nj01807a · Cited by 208
Sticher, P., Jaspers, M. C., Stemmler, K., Harms, H., Zehnder, A. J., & van der Meer, J. R. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.10.4053-4060.1997 · Cited by 207
Outten, C. E., Outten, F. W., & O'Halloran, T. V. (1999) · Journal of Biological Chemistry · doi:10.1074/jbc.274.53.37517 · Cited by 199 · cited 1×
“Regulatory proteins of zntA and copA belong to the MerR homologue, thereby making them responsible for Hg [60,61].”
BackgroundWhole-Cell-Based Biosensors for Environmental Biomonitoring and Application
Gu, M. B., Mitchell, R. J., & Kim, B. C. (2004) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/b13533 · Cited by 185 · cited 2×
“The luxAB is enough for producing the luminescence, while using the whole luxCDABE operon could reduce the amount of additional substrates that is needed for luminescence reaction [15].”
BackgroundMethodJayaraman, T., Murthy, A. P., Elakkiya, V., Chandrasekaran, S., Nithyadharseni, P., Khan, Z., Senthil, R. A., Shanker, R., Raghavender, M., Kuppusami, P., et al. (2018) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2018.02.029 · Cited by 183
Beard, S. J., Hashim, R., Membrillo‐Hernández, J., Hughes, M. N., & Poole, R. K. (1997) · Molecular Microbiology · doi:10.1111/j.1365-2958.1997.mmi518.x · Cited by 181 · cited 1×
“zntA accounts for the removal of intracellular Zn and responds to Cd and Pb [57,58].”
BackgroundAdvances in arsenic biosensor development – A comprehensive review
Kaur, H., Kumar, R., Babu, J. N., & Mittal, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.003 · Cited by 181 · cited 4×
“The arsR or arsD in ars operon for arsenic [14], the cadC/A in cad operon for cadmium [54], the merR in mer operon for mercury [6], and the chrB in chr operon for chromium were used in specific cell-based biosensors [55].”
BackgroundMethodInfluentialSohrabi, H., Hemmati, A., Majidi, M. R., Eyvazi, S., Jahanban‐Esfahlan, A., Baradaran, B., Adlpour-Azar, R., Mokhtarzadeh, A., & de la Guárdia, M. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116344 · Cited by 176 · cited 1×
“Currently, biosensors targeting heavy metals, pesticides, or pharmaceuticals show the advantages of biosensor such as portability, ease of use, and saving time [18,19].”
BackgroundCopper removal and microbial community analysis in single-chamber microbial fuel cell
Wu, Y., Zhao, X., Jin, M., Li, Y., Li, S., Kong, F., Nan, J., & Wang, A. (2018) · Bioresource Technology · doi:10.1016/j.biortech.2018.01.046 · Cited by 172 · cited 2×
“[105] also found at a level of 12 mg L in their study.”
BackgroundRemoval of Hg2+ as an electron acceptor coupled with power generation using a microbial fuel cell
Wang, Z., Lim, B., & Choi, C. (2011) · Bioresource Technology · doi:10.1016/j.biortech.2011.02.027 · Cited by 172
Microbial Fuel Cell-Based Biosensors
Cui, Y., Lai, B., & Tang, X. (2019) · Biosensors · doi:10.3390/bios9030092 · Cited by 167 · cited 1×
“Microbial fuel cell (MFC)-based biosensors with single- or dual-chamber design were developed based on the oxidation of organic compounds and the corresponding electrical currents [80,81].”
MethodNanomaterial-based aptamer sensors for arsenic detection
Mao, K., Zhang, H., Wang, Z., Cao, H., Zhang, K., Li, X., & Yang, Z. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111785 · Cited by 159 · cited 1×
“Biosensors are robust environmental monitoring solutions with important novel characteristics and advantages [173].”
BackgroundDempsey, E., Diamond, D., & Collier, A. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.02.007 · Cited by 158
A batch-mode cube microbial fuel cell based “shock” biosensor for wastewater quality monitoring
Liu, B., Lei, Y., & Li, B. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.051 · Cited by 153 · cited 1×
“The toxic metals (Cr and Fe), NO3, and sodium acetate in the wastewater from Connecticut (USA) could be assessed by the batch mode MFC-based biosensors [178].”
BackgroundYu, D., Bai, L., Zhai, J., Wang, Y., & Dong, S. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.048 · Cited by 153 · cited 1×
“regulatory protein types connected with these promoters, as well as the reporter genes for transcriptional pollutants control [101,102].”
BackgroundTheerthagiri, J., Senthil, R. A., Malathi, A., Selvi, A., Madhavan, J., & Ashokkumar, M. (2015) · RSC Advances · doi:10.1039/c5ra06512g · Cited by 148
A microbial biosensor to predict bioavailable nickel in soil and its transfer to plants
Tibazarwa, C., Corbisier, P., Mench, M. J., Bossus, A., Solda, P., Mergeay, M., Wyns, L., & van der Lelie, D. (2001) · Environmental Pollution · doi:10.1016/s0269-7491(00)00177-9 · Cited by 144 · cited 1×
“The cnrYXH gene was used to detect the bioavailability of Co and Ni in soil [62].”
MethodChouteau, C., Dzyadevych, S. V., Chovelon, J., & Durrieu, C. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.10.012 · Cited by 141 · cited 1×
“For example, a new conductometric biosensor based on alkaline phosphatase activity was developed utilizing immobilized whole-cell microalgae to detect cadmium ions in aquatic environments and habitats [136].”
BackgroundSoldatkin, O. O., Kucherenko, I. S., Pyeshkova, V. M., Кукла, А. Л., Jaffrezic-Renault, N. J., El'skaya, A. V., Dzyadevych, S. V., & Soldatkin, A. P. (2011) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2011.08.001 · Cited by 141
Heavy metal whole-cell biosensors using eukaryotic microorganisms: an updated critical review
Gutiérrez, J. C., Amaro, F., & MartÃn-González, A. (2015) · Frontiers in Microbiology · doi:10.3389/fmicb.2015.00048 · Cited by 139 · cited 1×
“Several studies have used eukaryotic microorganisms to investigate whole-cell biosensors for environmental pollution monitoring of heavy metals in aquatic habitats or soils [135].”
BackgroundEffect of shear rate on the response of microbial fuel cell toxicity sensor to Cu(II)
Shen, Y., Wang, M., Chang, I. S., & Ng, H. Y. (2013) · Bioresource Technology · doi:10.1016/j.biortech.2013.02.069 · Cited by 135 · cited 1×
“[104] designed a toxicity MFC system for detecting Cu concentrations of 5–7 mg L in a quick speedy response, and Wu et al.”
Mauriz, E., Calle, A., Abad‐Fuentes, A., Montoya, A., Hildebrandt, A., Barceló, ., & Lechuga, L. M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.013 · Cited by 134
Microbial fuel cell-based biosensors for environmental monitoring: a review.
Sun, J.-Z., Kingori, G. P., Si, R.-W., Zhai, D.-D., Liao, Z.-H., Sun, D.-Z., Zheng, T., & Yong, Y.-C. (2015) · Water Science and Technology · doi:10.2166/wst.2015.035 · Cited by 128 · cited 3×
“The dual chambers of MFC-based biosensors consist of an anaerobic anodic chamber where the oxidation happens and aerobic cathodic chamber, transferring electrons through circuits and protons through the ion-exchange membrane from anode to cathode [82].”
BackgroundInfluentialMFC-based biosensor for domestic wastewater COD assessment in constructed wetlands
Corbella, C., Hartl, M., Fernández-Gatell, M., & Puigagut, J. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.12.347 · Cited by 126 · cited 1×
“The COD in domestic wastewater from Spain discharged into constructed wetlands could be monitored by MFCbased biosensors [183].”
BackgroundZehani, N., Fortgang, P., Lachgar, M. S., Baraket, A., Arab, M., Dzyadevych, S. V., Kherrat, R., & Jaffrezic-Renault, N. J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.051 · Cited by 120
Atar, N., Eren, T., Yola, M. L., & Wang, S. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.04.076 · Cited by 120 · cited 1×
“Household wastes also contribute to organic pollutants in wastewater such as phenyl ether which is found in everyday household products such as soaps, deodorants, plastics and cosmetics [144].”
BackgroundBilal, M., & Iqbal, H. M. N. (2019) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2019.01.032 · Cited by 119 · cited 4×
“The mechanisms of bioluminescence-based inhibitory biosensors might be associated with the ATP reduction resulted from stress responsive mechanisms or cell death resulted from excessive environmental stress, which further decreased the bioluminescence by lower ATP and cell viability [17,66].”
BackgroundInfluentialNanomaterials based electrochemical nucleic acid biosensors for environmental monitoring: A review
Hashem, A., Hossain, M. A. M., Marlinda, A. R., Mamun, M. A., Simarani, K., & Johan, M. R. (2021) · Applied Surface Science Advances · doi:10.1016/j.apsadv.2021.100064 · Cited by 118 · cited 1×
“, heavy metals have been discussed [126,127].”
Riether, K., Dollard, M.-A., & Billard, P. (2001) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-001-0852-0 · Cited by 114 · cited 1×
“zntA and copA promoter/operator evaluated the bioavailability of Zn and Cu [56].”
BackgroundElectroactive Biofilms for Sensing: Reflections and Perspectives
Prévoteau, A., & Rabaey, K. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00418 · Cited by 112 · cited 1×
“0 to 10 mg L range for ions, including Cr, Hg and Pb [107].”
BackgroundGreen fluorescent protein-based biosensor for detecting SOS-inducing activity of genotoxic compounds
Kostrzynska, M., Leung, K. T., Lee, H., & Trevors, J. T. (2002) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(01)00335-9 · Cited by 103 · cited 1×
“The recA and its promoter responsible for DNA repair and maintenance were widely used in DNA damagesensing biosensors for their response to genotoxic compounds and pharmaceuticals [34,68,69].”
BackgroundGao, G., Fang, D., Yu, Y., Wu, L., Wang, Y., & Zhi, J. (2017) · Talanta · doi:10.1016/j.talanta.2017.01.081 · Cited by 102 · cited 1×
“The multiple heavy metals and phenols in real wastewater samples from China were able to be detected by MFC-based biosensors [176].”
BackgroundBegildayeva, T., Lee, S. J., Yu, Y., Park, J., Kim, T. H., Theerthagiri, J., Ahn, A., Jung, H. J., & Choi, M. Y. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.124412 · Cited by 101
Analysis of bisphenol A in natural waters by means of an optical immunosensor
Rodríguez‐Mozaz, S., de Alda, M. L., & Barceló, . (2005) · Water Research · doi:10.1016/j.watres.2005.09.023 · Cited by 101
Alex, A. V., & Mukherjee, A. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105779 · Cited by 99 · cited 1×
“ducing from the reaction of acetylcholinesterase [27].”
Smirnova, I. A., Dian, C., Leonard, G. A., et al. (2004) · Journal of Molecular Biology · doi:10.1016/j.jmb.2004.04.071 · Cited by 95
Review of recent progress on DNA-based biosensors for Pb2+ detection
Yang, Y., Li, W., & Liu, J. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.12.056 · Cited by 88
Rampley, C. P. N., Whitehead, P. G., Softley, L. K., Hossain, M., Jin, L., David, J., Shawal, S., Das, P., Thompson, I. P., Huang, W. E., et al. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.134760 · Cited by 88
Verma, M. L., & Rani, V. (2020) · Environmental Chemistry Letters · doi:10.1007/s10311-020-01116-4 · Cited by 87 · cited 1×
“Other substances including pesticides and EDCs could be detected in river water and wastewater by biosensors especially nanomaterialsbased ones, suggesting their feasibility in real environmental samples [166].”
BackgroundA primer on emerging field-deployable synthetic biology tools for global water quality monitoring
Thavarajah, W., Verosloff, M. S., Jung, J. K., Alam, K. K., Miller, J. D., Jewett, M. C., Young, S. L., & Lucks, J. B. (2020) · npj Clean Water · doi:10.1038/s41545-020-0064-8 · Cited by 87 · cited 4×
“In addition, the large-scale screening of biosensor environmental analysis helps with precise measurements and saves electricity and energy [167].”
BackgroundInfluentialGreen Fluorescent Protein as a Noninvasive Stress Probe in Resting Escherichia coli Cells
Chi, H. J., Srivastava, R., Vakharia, V. N., Rao, G., & Bentley, W. E. (1999) · Applied and Environmental Microbiology · doi:10.1128/aem.65.2.409-414.1999 · Cited by 86
Billard, P., & DuBow, M. S. (1998) · Clinical Biochemistry · doi:10.1016/s0009-9120(97)00136-7 · Cited by 86 · cited 1×
“The luxCDABE from bacterial operon is conservative in many bacteria species [75].”
BackgroundTyrosinase-based biosensor for determination of bisphenol A in a flow-batch system
Kochana, J., Wapiennik, K., Kozak, J., Knihnicki, P., Pollap, A., Woźniakiewicz, M., Nowak, J., & Kościelniak, P. (2015) · Talanta · doi:10.1016/j.talanta.2015.05.078 · Cited by 85
Ravikumar, S., Baylon, M. G., Park, S. J., & Choi, J. (2017) · Microbial Cell Factories · doi:10.1186/s12934-017-0675-z · Cited by 85 · cited 2×
“The regulatory membrane protein has the ability to bind pollutants and then trigger downstream phosphorylation of the other regulator proteins that activate the signal transduction [94].”
BackgroundRecent advances in the electrochemical detection of mercury
Martín‐Yerga, D., & Costa‐García, A. (2017) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2017.06.012 · Cited by 84 · cited 2×
“DNA-based electrodes biosensor is an excellent candidate for Hg detection, with a LOD of 3 fM [127].”
BackgroundBontidean, I., Lloyd, J. R., Hobman, J. L., Wilson, J. R., Csöregi, E., Mattìasson, B., & Brown, N. L. (2000) · Journal of Inorganic Biochemistry · doi:10.1016/s0162-0134(99)00234-2 · Cited by 82 · cited 1×
“Both toxic metals and excessive essential metals could trigger the response of resistance or detoxification genes [52,53].”
BackgroundZhao, S., Liu, P., Niu, Y., Chen, Z., Khan, A., Zhang, P., & Li, X. (2018) · Sensors · doi:10.3390/s18020642 · Cited by 82 · cited 1×
“A similar study was conducted using Pseudomonas and Geobacter for in-situ Cr detection in real-time from industrial wastewater [106].”
MethodAdekunle, A., Raghavan, V., & Tartakovsky, B. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.11.007 · Cited by 81 · cited 1×
“Similarly, the brewery wastewater obtained from Canada containing COD and others such as NH4 was shown to successfully monitored by MFC-based biosensors [179].”
BackgroundKumar, T. S., Naik, S., & Eswari, S. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2021.133098 · Cited by 81
Measuring Carbon Footprint of an Indian University Using Life Cycle Assessment
Sangwan, K. S., Bhakar, V., Arora, V., & Solanki, P. K. (2018) · Procedia CIRP · doi:10.1016/j.procir.2017.11.111 · Cited by 81
Advances in olfaction-inspired biomaterials applied to bioelectronic noses
Wasilewski, T., Gębicki, J., & Kamysz, W. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.10.086 · Cited by 81 · cited 1×
“Advances in the field of biotechnology have enabled biological materials to function as receptors, so these bioreceptors can analyze VOCs with high selectivity and sensitivity [161].”
BackgroundAn Escherichia coli biosensor capable of detecting both genotoxic and oxidative damage
Mitchell, R. J., & Gu, M. B. (2004) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-003-1418-0 · Cited by 81
Guo, M., Wang, J., Du, R., Liu, Y., Chi, J., He, X., Huang, K., Luo, Y., & Xu, W. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111899 · Cited by 80 · cited 1×
“[137] illustrated that a fluorescent wholecell biosensor could detect mercury (Hg) contamination in cosmetics with the detection range from 50 nM to 10 μM with incubating time for two hours.”
BackgroundDevelopment of lab-on-chip biosensor for the detection of toxic heavy metals: A review
Karthik, V., Karuna, B., Kumar, P. S., Saravanan, A., & Hemavathy, R. V. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2022.134427 · Cited by 79 · cited 1×
“Due to their pronounced toxicity, these heavy metals are important for monitoring the environment (water, wastewater, air, solid waste, and organisms) [95,97,98].”
BackgroundKurvet, I., Ivask, A., Bondarenko, O. M., Sihtmäe, M., & Kahru, A. (2011) · Sensors · doi:10.3390/s110807865 · Cited by 72 · cited 3×
“Similarly, the constitutively expressed bioluminescence of these toxicity-based nonspecific biosensors would diminish upon the exposure of toxicants, thereby making them capable of quantifying the general toxicity equivalent of multiple pollutants [66].”
BackgroundGenetic control of violacein biosynthesis to enable a pigment-based whole-cell lead biosensor
Hui, C.-Y., Guo, Y. L., Liu, L., Zhang, N.-X., Gao, C.-X., Yang, X., & Yi, J. (2020) · RSC Advances · doi:10.1039/d0ra04815a · Cited by 72 · cited 1×
“In addition, the Pb(II)-binding regulator PbrR in MerR family has the ability to recognize lead after being engineered in wholecell biosensor [63].”
BackgroundRiangrungroj, P., Bever, C. S., Hammock, B. D., & Polizzi, K. M. (2019) · Scientific Reports · doi:10.1038/s41598-019-48907-6 · Cited by 68 · cited 1×
“For simple and rapid on-site use, the colorimetric biosensors for pyrethroid insecticide and halogenated hydrocarbons performed well in testing samples [168,169].”
BackgroundA novel biosensor for zinc detection based on microbial fuel cell system
Khan, A., Salama, E., Chen, Z., Ni, H., Zhao, S., Zhou, T., Pei, Y., Sani, R. K., Ling, Z., Liu, P., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111763 · Cited by 68 · cited 1×
“The riboflavin and porin are responsible for facilitating electron transfer and improving cell membrane permeability, respectively [87,88].”
BackgroundStoytcheva, M., Sharkova, V., & Panayotova, M. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00134-2 · Cited by 64 · cited 1×
“ities can help detect toxic metals like arsenic [25,26].”
BackgroundShi, L., Wang, Y., Ding, S., Chu, Z., Yin, Y., Jiang, D., Luo, J., & Jin, W. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.104 · Cited by 62 · cited 3×
“[133] used a biosensing system for detecting Hg in tap and lake water samples with a 3D graphene/ gold electrode and a reporter probe attached to Au nanoparticles.”
BackgroundMethodLee, S. J., Lee, H., Begildayeva, T., Yu, Y., Theerthagiri, J., Kim, Y., Lee, Y. W., Han, S. W., & Choi, M. Y. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113766 · Cited by 58 · cited 1×
“Applying electrochemical DNA biosensors for heavy metals detection includes implementing core-shell nanoparticles, nicking enzyme–assisted amplification, and nanocomposites modification [124,125].”
MethodChung, T. H., Meshref, M. N. A., & Dhar, B. R. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.130245 · Cited by 58 · cited 1×
“In addition, the nonspecific biosensor based on microbial electrochemical cell-based (MXC) structure can be successfully used to monitor PCBs and PAHs such as toluene [163].”
MethodXiao, N., Selvaganapathy, P. R., Wu, R., & Huang, J. J. (2020) · Bioresource Technology · doi:10.1016/j.biortech.2020.122777 · Cited by 58 · cited 1×
“In addition to pollutant-degrading bacteria, the electroactive bacteria such as Geobacter and Shewanella were shown to facilitate the current production in MFCbased biosensor [84].”
BackgroundRecent Progress in the Development of Biosensors for Chemicals and Pesticides Detection
Hashwan, S. S. B., Khir, M. H. M., Al-Douri, Y., & Ahmed, A. Y. (2020) · IEEE Access · doi:10.1109/access.2020.2991380 · Cited by 56 · cited 1×
“Researchers want to resolve these challenges to enhance the biosensor application at advanced levels [187].”
BackgroundRoy, R., Ray, S., Chowdhury, A., & Anand, R. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00329 · Cited by 55 · cited 1×
“For specific targeting of benzene, phenol, toluene, and other related pollutants, engineered whole-cell biosensors based on the metabolic genes as sensing elements were developed [164,165].”
BackgroundDNAzyme-based biosensors for mercury (Ⅱ) detection: Rational construction, advances and perspectives
Cheng, Z., Wei, J., Gu, L., Zou, L., Wang, T., Chen, L., Li, Y., Yang, Y. P., & Li, P. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.128606 · Cited by 53 · cited 4×
“In contrast, Hg, Pb and Cd levels are strictly monitored by the European Union [103] due to these substances’ highly toxic, bioaccumulative properties, and their impact on human health and the environment [133].”
BackgroundMethodInfluentialAli, S. A., Mittal, D., & Kaur, G. (2021) · World Journal of Microbiology and Biotechnology · doi:10.1007/s11274-021-03024-3 · Cited by 53 · cited 2×
“The Cd detecting protein cadC regulator could be used in biosensor for Cd detection [16].”
BackgroundHang, M., Ngo, H. H., Guo, W., Chang, S. W., Nguyen, D. D., Pandey, A., Sharma, P., Varjani, S., Nguyen, T. A. H., & Hoang, N. B. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.152261 · Cited by 53 · cited 2×
“0–10 mg L) with added Cu/As to the anolyte solution [83].”
BackgroundMethodSelf-citationKannappan, S., & Ramisetty, B. C. M. (2021) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-021-03734-2 · Cited by 52 · cited 2×
“For heavy metals, the resistance and detoxification mechanisms were applied in the sensing elements of specific whole-cell biosensors [92].”
BackgroundTran, .-T., Dang, B., Thuy, L. T. T., Hoang, H.-G., Bui, X., Le, V., Lin, C., Nguyen, M., Nguyen, K.-Q., Nguyen, P.-T., et al. (2022) · Current Pollution Reports · doi:10.1007/s40726-022-00221-y · Cited by 51
Self-citationRisk-Based Evaluation of Total Petroleum Hydrocarbons in Vapor Intrusion Studies
Brewer, R., Nagashima, J., Kelley, M., Heskett, M., & Rigby, M. C. (2013) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph10062441 · Cited by 49 · cited 1×
“For unique applications, biosensors can be personalized such as TPHs screening kit which is a favored tool for monitoring analytes on site in different media (soil, water and vapor) [170].”
BackgroundUse of microtox tests for screening industrial wastewater toxicity
Hao, O. J., Chien-Jen, S., Lin, C., Jeng, F., & Zen-Chyuan, C. (1996) · Water Science & Technology · doi:10.1016/s0273-1223(96)00695-6 · Cited by 46 · cited 1×
“The Microtox test has been devised using the bacterium Vibrio fischeri whose bioluminescence would diminish due to the toxicity and disrupted metabolism [64,65].”
MethodSelf-citationMa, J., Bai, W., & Zheng, J. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113801 · Cited by 45 · cited 3×
“7 nM, and the linear range of 5 nM–5 μM [123].”
BackgroundInfluentialCurrent and potential biotechnological applications of odorant-binding proteins
Brito, N. F., Oliveira, D. S., Santos, T. C., Moreira, M. F., & Melo, A. C. A. (2020) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-020-10860-0 · Cited by 44 · cited 1×
“Some applications can detect VOCs based on protein and peptides biosensors, such as sensitive olfactory biosensors having a remarkable performance for high selectivity and sensitivity at very low concentrations by using odorant-binding protein (OBP) operated as a sensing component [162].”
BackgroundYamashita, T., Hasegawa, T., Hayashida, Y., Ninomiya, K., Shibata, S., Ito, K., Mizuguchi, H., & Yokoyama, H. (2021) · Biochemical Engineering Journal · doi:10.1016/j.bej.2021.108266 · Cited by 44 · cited 1×
“In addition, The MFC-based BOD biosensor was used in monitoring swine wastewater in Japan, which minimizes the energy cost for aeration [175].”
MethodHui, C.-Y., Guo, Y. L., Gao, C.-X., Li, H., Lin, Y., Yun, J.-P., Chen, Y., & Yi, J. (2022) · Environmental Technology & Innovation · doi:10.1016/j.eti.2022.102511 · Cited by 44 · cited 1×
“In groundwater and river water samples, the bioavailable and toxic fractions of metals and organic pollutants such as Cd and toluene could be successfully evaluated using biosensors [9,10].”
BackgroundWhole-Cell Microbial Bioreporter for Soil Contaminants Detection
Zeng, N., Wu, Y., Chen, W., Huang, Q., & Cai, P. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622994 · Cited by 43 · cited 1×
“Biodegradable organic pollutants in the whole-cell biosensors trigger metabolic mechanisms and the downstream utilizing proteins or signals such as bioluminescence [8,90].”
BackgroundElectrochemical sensing systems for arsenate estimation by oxidation of l-cysteine
Sarkar, P., Banerjee, S., Bhattacharyay, D., & Turner, A. P. F. (2010) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2010.07.004 · Cited by 41 · cited 1×
“ities can help detect toxic metals like arsenic [25,26].”
BackgroundBacterial bioluminescence assay for bioanalysis and bioimaging
Li, Y., He, X., Zhu, W., Li, H., & Wang, W. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03695-9 · Cited by 41 · cited 1×
“, the recombinant Escherichia coli harboring the lux operon could successfully detect the environmental pollutants, suggesting the feasibility of lux operon engineered in other bacterial species that could be easily cultured [8,79].”
BackgroundAn evaluation of field total petroleum hydrocarbon (TPH) systems
Lambert, P., Fingas, M. F., & Goldthorp, M. (2001) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(00)00328-9 · Cited by 40
Mohseni, M., Abbaszadeh, J., Maghool, S.-S., & Chaichi, M. (2017) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2017.11.002 · Cited by 37 · cited 1×
“Therefore, the bioluminescence biosensors with lux operon such as Microtox (Vibrio fischeri) were applied in assessing the toxicity of environmental pollutants in river and sediment samples [71,77,78].”
MethodAerosol mass and major composition characterization of ambient air in Ho Chi Minh City, Vietnam
Phan, C. C., Hung, N. T. Q., Nguyen, M., Park, K.-H., Bae, G., Seung-bok, L., & Bach, Q. (2020) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-020-02640-0 · Cited by 37 · cited 1×
“Due to their pronounced toxicity, these heavy metals are important for monitoring the environment (water, wastewater, air, solid waste, and organisms) [95,97,98].”
BackgroundSelf-citationVoon, C. H., Yusop, N. M., & Khor, S. M. (2022) · Talanta · doi:10.1016/j.talanta.2022.123271 · Cited by 36 · cited 7×
“Currently, the successful application on VOCs and PAHs such as alkanes, toluene, naphthalene in wastewater, seawater, and soil using whole-cell luminescence biosensor has been reported [8].”
BackgroundMethodInfluentialOlaniran, A. O., Hiralal, L., & Pillay, B. (2011) · Journal of Environmental Monitoring · doi:10.1039/c1em10032g · Cited by 35 · cited 1×
“In South Africa, it has been shown that the influents and effluents from wastewater treatment plants were assessed by nonspecific whole-cell bioluminescence biosensors [181].”
BackgroundZhou, T., Li, R., Zhang, S., Zhao, S., Sharma, M., Kulshrestha, S., Khan, A., Kakade, A., Han, H., Niu, Y., et al. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27563 · Cited by 34 · cited 1×
“The riboflavin and porin are responsible for facilitating electron transfer and improving cell membrane permeability, respectively [87,88].”
BackgroundLi, P., Wang, Y., Yuan, X., Liu, X., Liu, C., Fu, X., Sun, D., Dang, Y., & Holmes, D. E. (2021) · Environmental Science and Ecotechnology · doi:10.1016/j.ese.2021.100092 · Cited by 32 · cited 2×
“For example, arsR and the promoter region from Geobacter sulfurreducens could be genetically combined with a fluorescence reporter, usable for arsenic screening with the detection limit down to the ppb level [41].”
BackgroundSingh, A., & Kumar, V. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02953-6 · Cited by 31 · cited 1×
“The regulatory systems consisted of regulatory protein that could bind metals and promoter regions that trigger downstream detoxification or signaling responses [92,93].”
BackgroundPatel, R., Zaveri, P., Mukherjee, A., Agarwal, P. K., More, P., & Munshi, N. S. (2019) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2019.109450 · Cited by 29 · cited 2×
“For specific targeting of benzene, phenol, toluene, and other related pollutants, engineered whole-cell biosensors based on the metabolic genes as sensing elements were developed [164,165].”
BackgroundA Recombinase-Based Genetic Circuit for Heavy Metal Monitoring
Akboğa, D., Saltepe, B., Bozkurt, E. U., & Şeker, U. Ö. Ş. (2022) · Biosensors · doi:10.3390/bios12020122 · Cited by 27 · cited 1×
“Similarly, the stress-inducible heat shock genes like hsp70 and its promoter were used in biosensors for detecting nonspecific toxicity since the heat shock protein systems will be triggered not only by heat shock but also other environmental stressors, and then induce the downstream fused signals [72,73].”
BackgroundYang, Y., Kang, M., Fang, S., Wang, M., He, L., Feng, X., Zhao, J., Zhang, Z. H., & Zhang, H. (2015) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2015.08.229 · Cited by 27
Zhou, D., Zeng, L., Pan, J., Li, Q., & Chen, J. (2019) · Talanta · doi:10.1016/j.talanta.2019.120258 · Cited by 26 · cited 2×
“For an LOD, it was 10 fM and the linear range was from 10 fM to 100 nM [134].”
BackgroundEffect of organics and alkalinity on the sulfur oxidizing bacteria (SOB) biosensor
Hassan, S. H. A., Ginkel, S. W. V., & Oh, S. (2012) · Chemosphere · doi:10.1016/j.chemosphere.2012.06.040 · Cited by 25
Carbon Footprint Modeling of a Clinical Lab
Ni, K., Hu, Y., Ye, X., AlZu’bi, H. S., Goddard, P., & Alkahtani, M. S. (2018) · Energies · doi:10.3390/en11113105 · Cited by 25
A simple whole cell microbial biosensors to monitor soil pollution
Prabhakaran, R., Ramprasath, T., & Selvam, G. S. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804299-1.00013-8 · Cited by 22 · cited 1×
“For terrestrial ecosystems this refers to SDG 15 (life on land), and the soil contaminants-detecting biosensor could be applied to screen potential soil pollution, which can guide what happens in terrestrial ecosystems [185,186].”
BackgroundReal-time Monitoring of Non-specific Toxicity Using a Saccharomyces cerevisiae Reporter System
Välimaa, A., Kivistö, A. T., Virta, M., & Karp, M. T. (2008) · Sensors · doi:10.3390/s8106433 · Cited by 21 · cited 2×
“The modified Saccharomyces cerevisiae with substrate luciferin could serve as a reporter system based on ATP-bioluminescence for detecting nonspecific toxicity [67].”
BackgroundMethodThe potential applications of SOS-luxbiosensors for rapid screening of mutagenic chemicals
Alhadrami, H. A., & Paton, G. I. (2013) · FEMS Microbiology Letters · doi:10.1111/1574-6968.12156 · Cited by 18
Brányiková, I., Lucáková, S., Kuncová, G., Trögl, J., Synek, V., Rohovec, J., & Navrátil, T. (2020) · Sensors · doi:10.3390/s20113138 · Cited by 17 · cited 1×
“Moreover, bioavailability of the pollutants such as Hg and phenanthrene was revealed by the use of biosensors [11,12], suggesting the useful application of biosensors on bioavailability assessment of pollutants in the environmental samples.”
BackgroundChen, X., Yao, H., Song, D. H., Sun, G., & Xu, M. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.133266 · Cited by 15 · cited 3×
“However, limited information about the key sensing element based on the metabolic mechanisms of microorganisms constrain the development of biosensors for specific organic pollutants such as emerging contaminants [91].”
BackgroundMethodologies for Analysis and Identification of Total Petroleum Hydrocarbons
Kuppusamy, S., Maddela, N. R., Megharaj, M., & Venkateswarlu, K. (2019) · Springer eBooks · doi:10.1007/978-3-030-24035-6_2 · Cited by 15 · cited 2×
“It has been suggested that TPHs immunoassay is one of the most widely used methods to quickly detect petroleum compounds especially in soil samples [171,172].”
BackgroundMethodBabapoor, A., Hajimohammadi, R., Jokar, S. M., & Paar, M. (2020) · Journal of Chemistry · doi:10.1155/2020/9120959 · Cited by 14 · cited 1×
“For terrestrial ecosystems this refers to SDG 15 (life on land), and the soil contaminants-detecting biosensor could be applied to screen potential soil pollution, which can guide what happens in terrestrial ecosystems [185,186].”
BackgroundTsai, S.-T., Cheng, W.-J., Zhang, Q.-X., & Yeh, Y.-C. (2021) · ACS Synthetic Biology · doi:10.1021/acssynbio.1c00520 · Cited by 11
Cited by
Enhancing the sustainability of microalgae cultivation through biosensing technology
Ugya, A. Y., Chen, H., & Wang, Q. (2025) · Materials Today Sustainability · doi:10.1016/j.mtsust.2025.101139 · Cited by 5
Metadata
- Authors
- Huang, C.-W., Lin, C., Nguyen, M. K., Hussain, A., Bui, X.-T., & Ngo, H. H.
- Venue
- Bioengineered
- Publisher
- Informa UK Limited
- Published
- 2023-06-28
- Volume
- 14
- Issue
- 1
- Pages
- 58-80
- ISSN
- 2165-5979 (ISSN-L)
- 2165-5987
- OpenAlex
- W4382345317
- Cited by
- 227
- References
- 135
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.