Analytical comparisons of SARS-COV-2 detection by qRT-PCR and ddPCR with multiple primer/probe sets
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Different primers/probes sets have been developed all over the world for the nucleic acid detection of SARS-CoV-2 by quantitative real time polymerase chain reaction (qRT-PCR) as a standard method. In our recent study, we explored the feasibility of droplet digital PCR (ddPCR) for clinical SARS-CoV-2 nucleic acid detection compared with qRT-PCR using the same primer/probe sets issued by Chinese Center for Disease Control and Prevention (CDC) targeting viral ORF1ab or N gene, which showed that ddPCR could largely minimize the false negatives reports resulted by qRT-PCR [Suo T, Liu X, Feng J, et al. ddPCR: a more sensitive and accurate tool for SARS-CoV-2 detection in low viral load specimens. medRxiv [Internet]. 2020;2020.02.29.20029439. Available from: https://medrxiv.org/content/early/2020/03/06/2020.02.29.20029439.abstract]. Here, we further stringently compared the performance of qRT-PCR and ddPCR for 8 primer/probe sets with the same clinical samples and conditions. Results showed that none of 8 primer/probe sets used in qRT-PCR could significantly distinguish true negatives and positives with low viral load (10−4 dilution). Moreover, false positive reports of qRT-PCR with UCDC-N1, N2 and CCDC-N primers/probes sets were observed. In contrast, ddPCR showed significantly better performance in general for low viral load samples compared to qRT-PCR. Remarkably, the background readouts of ddPCR are relatively lower, which could efficiently reduce the production of false positive reports.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR
Corman, V. M., Landt, O., Kaiser, M., Molenkamp, R., Meijer, A., Chu, D. K., Bleicker, T., Brünink, S., Schneider, J., Schmidt, M. L., et al. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.3.2000045 · Cited by 7,344 · cited 2×
“Supplemental data for this article can be accessed https://doi.org/10.1080/22221751.2020.1772679. simultaneously using the primer/probe sets issued by different institutions (Table S1), including CCDC [5], Hong Kong University (HKU) [6], Charité (Universitätsmedizin Berlin Institute of Virology, Germany) [7], and Unit…”
BackgroundInfluential(2013) · Europe PMC (PubMed Central) · Cited by 2,089
Aerodynamic Analysis of SARS-CoV-2 in Two Wuhan Hospitals
Liu, Y., Ning, Z., Chen, Y., Guo, M., Liu, Y., Gali, N. K., Sun, L., Duan, Y., Cai, J., Westerdahl, D., et al. (2020) · Nature · doi:10.1038/s41586-020-2271-3 · Cited by 1,872 · cited 1×
“However, ddPCR would be more ideal method for quantitation with special requirements for sensitivity and precision [11].”
MethodSelf-citationMolecular Diagnosis of a Novel Coronavirus (2019-nCoV) Causing an Outbreak of Pneumonia
Chu, D. K. W., Pan, Y., Cheng, S. M. S., Hui, K. P. Y., Krishnan, P., Liu, Y., Ng, D. Y. M., Wan, C. K. C., Yang, P., Wang, Q., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa029 · Cited by 1,278
Chen, L., Liu, W., Zhang, Q., Xu, K., Ye, G., Wu, W., Sun, Z., Liu, F., Wu, K., Zhong, B., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1725399 · Cited by 570 · cited 2×
“coronavirus (SARS-CoV-2, also refers as HCOV-19) [1,2] has raised an urgent requirement for clinical pathogen diagnosis.”
BackgroundSelf-citationValidation of Laboratory-Developed Molecular Assays for Infectious Diseases
Burd, E. M. (2010) · Clinical Microbiology Reviews · doi:10.1128/cmr.00074-09 · Cited by 550 · cited 1×
“using universal methods with standard materials or lots of patients’ samples, which were not included in this study [9,10].”
MethodddPCR: a more accurate tool for SARS-CoV-2 detection in low viral load specimens
Suo, T., Liu, X., Feng, J., Guo, M., Hu, W., Guo, D., Ullah, H., Yang, Y., Zhang, Q., Wang, X., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1772678 · Cited by 450
Self-citationA distinct name is needed for the new coronavirus
Jiang, S., Shi, Z., Shu, Y., Song, J., Gao, G. F., Tan, W., & Guo, D. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30419-0 · Cited by 329 · cited 2×
“coronavirus (SARS-CoV-2, also refers as HCOV-19) [1,2] has raised an urgent requirement for clinical pathogen diagnosis.”
BackgroundSelf-citation
Cited by
Characterizing long COVID in an international cohort: 7 months of symptoms and their impact
Davis, H. E., Assaf, G. S., McCorkell, L., Wei, H., Low, R. J., Re'em, Y., Redfield, S., Austin, J. P., & Akrami, A. (2021) · eClinicalMedicine · doi:10.1016/j.eclinm.2021.101019 · Cited by 2,881
“The sensitivity of diagnostic tests may depend on the primer/probe sets [38,39].”
BackgroundSafiabadi Tali, S. H., LeBlanc, J. J., Sadiq, Z., Oyewunmi, O. D., Camargo, C., Nikpour, B., Armanfard, N., Sagan, S. M., & Jahanshahi-Anbuhi, S. (2021) · Clinical Microbiology Reviews · doi:10.1128/cmr.00228-20 · Cited by 405
Characterizing Long COVID in an International Cohort: 7 Months of Symptoms and Their Impact
Davis, H. E., Assaf, G. S., McCorkell, L., Wei, H., Low, R. J., Re’em, Y., Redfield, S., Austin, J. P., & Akrami, A. (2020) · medRxiv · doi:10.1101/2020.12.24.20248802 · Cited by 387
COVID-19 Antibody Tests and Their Limitations
Liu, G., & Rusling, J. F. (2021) · ACS Sensors · doi:10.1021/acssensors.0c02621 · Cited by 219
Zuo, W., He, D., Liang, C., Du, S., Hua, Z., Nie, Q., Zhou, X., Yang, M., Tan, H., Xu, J., et al. (2024) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(24)00171-3 · Cited by 191
Self-citation
Metadata
- Authors
- Liu, X., Feng, J., Zhang, Q., Guo, D., Zhang, L., Suo, T., Hu, W., Guo, M., Wang, X., Huang, Z., Xiong, Y., Chen, G., Chen, Y., & Lan, K.
- Venue
- Emerging Microbes & Infections
- Publisher
- Informa UK Limited
- Published
- 2020-01
- Volume
- 9
- Issue
- 1
- Pages
- 1175-1179
- ISSN
- 2222-1751 (ISSN-L)
- OpenAlex
- W3028345044
- Cited by
- 158
- References
- 8
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.