Scaling of musculoskeletal models from static and dynamic trials
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Subject-specific scaling of cadaver-based musculoskeletal models is important for accurate musculoskeletal analysis within multiple areas such as ergonomics, orthopaedics and occupational health. We present two procedures to scale ‘generic’ musculoskeletal models to match segment lengths and joint parameters to a specific subject and compare the results to a simpler approach based on linear, segment-wise scaling. By incorporating data from functional and standing reference trials, the new scaling approaches reduce the model sensitivity to assumed model marker positions. For validation, we applied all three scaling methods to an inverse dynamics-based musculoskeletal model and compared predicted knee joint contact forces to those measured with an instrumented prosthesis during gait. Additionally, a Monte Carlo study was used to investigate the sensitivity of the knee joint contact force to random adjustments of the assumed model marker positions (+/− one marker diameter). The model based on linear scaling showed the highest variation in the knee joint contact force of 1.44 body weight (BW) around contra-lateral heel strike, and a variation in root mean square deviation (RMSD) of 0.36 BW. The proposed methods reduced the variation to 1.0 BW (RMSD 0.26 BW) for the anatomical landmark based method and 0.47 BW (RMSD 0.06 BW) for the functional based method. Variation in model predictions due to uncertainty in marker positions is a trait of all marker-based musculoskeletal modelling approaches. The presented methods solve part of this problem and rely less on manual identification of anatomical landmarks in the model. The work represents a step towards a more consistent methodology in musculoskeletal modelling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933 · cited 1×
“The dependency on the operator is especially relevant in the context of general musculoskeletal modelling packages such as LifeMOD (Lifemodeler Inc 2010), SIMM (Musculographics Inc 2013), AnyBody (Damsgaard et al. 2006) and OpenSim (Delp et al. 2007).”
MethodWu, G., van der Helm, F. C. T., (DirkJan) Veeger, H. E. J., Makhsous, M., Van Roy, P., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K., Wang, X., et al. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,558
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., D’Lima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,242 · cited 2×
“In the lack of standardised recommendations for the knee joint, a definition following the same principles as the ISB recommendations was used.”
BackgroundAnalysis of musculoskeletal systems in the AnyBody Modeling System
Damsgaard, M., Rasmussen, J., Christensen, S. T., Surma, E., & de Zee, M. (2006) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2006.09.001 · Cited by 1,031 · cited 8×
“This is currently the standard method for the gait model examples included in the user-contributed model repository (the AnyBody Managed Model Repository (AMMR)) accompanying the AnyBody Modeling System.”
MethodSelf-citationModel-based estimation of muscle forces exerted during movements
Erdemir, A., McLean, S., Herzog, W., & van den Bogert, A. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.09.005 · Cited by 872 · cited 1×
“Subject-specific musculoskeletal models have the potential to assist in many clinical problems within rehabilitation and orthopaedics (Erdemir et al. 2007).”
BackgroundGrand challenge competition to predict in vivo knee loads
Fregly, B. J., Besier, T. F., Lloyd, D. G., Delp, S. L., Banks, S. A., Pandy, M. G., & D'Lima, D. D. (2012) · Journal of Orthopaedic Research · doi:10.1002/jor.22023 · Cited by 596 · cited 3×
“Secondly, the open nature of the dataset and the fact that other groups have used the same dataset in their work to create musculoskeletal models creates the opportunity to compare results with other published research (Fregly et al. 2012; Chen et al. 2014).”
BackgroundMethodResultHuman movement analysis using stereophotogrammetry
Della Croce, U., Leardini, A., Chiari, L., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.003 · Cited by 544
Repeatability of gait data using a functional hip joint centre and a mean helical knee axis
Besier, T. F., Sturnieks, D. L., Alderson, J. A., & Lloyd, D. G. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00087-3 · Cited by 532 · cited 3×
“The performance of functional methods has also been investigated in the literature although to a lesser extent, since these methods are still evolving (Besier et al. 2003; Pohl et al. 2010).”
BackgroundMethodMorphological muscle and joint parameters for musculoskeletal modelling of the lower extremity
Klein Horsman, M. D., Koopman, H. F. J. M., van der Helm, F. C. T., Prosé, L. P., & Veeger, H. E. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.10.003 · Cited by 445 · cited 2×
“It makes it possible to build upon the works of others, which has been exploited in the current study by taking the existing implementations of the Klein Horsman et al. (2007) cadaver dataset to serve the role of a musculoskeletal template geometry.”
MethodHuman movement analysis using stereophotogrammetryPart 1: theoretical background
CAPPOZZO, A., DELLACROCE, U., LEARDINI, A., & CHIARI, L. (2005) · Gait & Posture · doi:10.1016/s0966-6362(04)00025-6 · Cited by 398
Verification and validation benchmarks
Oberkampf, W. L., & Trucano, T. G. (2008) · Nuclear Engineering and Design · doi:10.1016/j.nucengdes.2007.02.032 · Cited by 236
Determination of patient-specific multi-joint kinematic models through two-level optimization
Reinbolt, J. A., Schutte, J. F., Fregly, B. J., Koh, B. I., Haftka, R. T., George, A. D., & Mitchell, K. H. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.03.031 · Cited by 233 · cited 2×
“In terms of the latter, attempts have been made to investigate the sensitivity of joint parameter optimisation to random noise in the marker data (Reinbolt et al. 2005).”
BackgroundMethodAndersen, M. S., Damsgaard, M., MacWilliams, B., & Rasmussen, J. (2010) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840903067080 · Cited by 188 · cited 3×
“International Biomechanics, 2015 Vol. 2, No. 1, 1–11, http://dx.doi.org/10.1080/23335432.2014.993706 subset of the markers (Andersen et al. 2010), but the remaining markers have to be placed manually.”
BackgroundSelf-citationVerification and validation benchmarks.
Oberkampf, W. L., & Trucano, T. G. (2007) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/901974 · Cited by 187
Kinematic analysis of over-determinate biomechanical systems
Andersen, M. S., Damsgaard, M., & Rasmussen, J. (2009) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840802459412 · Cited by 179 · cited 2×
“…from the traditional approach of linearly scaling musculoskeletal models, the actual implementation shares the same basic two-step structure: Firstly, the kinematic analysis uses an overdeterminate kinematic solver (Andersen et al. 2009) to track the experimental markers in a least-squares sense.”
MethodSelf-citationOn validation of multibody musculoskeletal models
Lund, M. E., de Zee, M., Andersen, M. S., & Rasmussen, J. (2012) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411911431516 · Cited by 176 · cited 3×
“Such modelling systems and their associated models have a host of parameters that require manual calibration before they can be applied to specific subjects or in specific applications (Lund et al. 2012).”
BackgroundSelf-citationPohl, M. B., Lloyd, C. H., & Ferber, R. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.07.020 · Cited by 113
da Silva, J. D. F., de Oliveira, H. C., Marcos, C. M., da Silva, R. A. M., da Costa, T. A., Calich, V. L. G., Fusco‐Almeida, A. M., & Mendes‐Giannini, M. J. S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0142028 · Cited by 82
Chen, Z., Zhang, X., Ardestani, M. M., Wang, L., Liu, Y., Lian, Q., He, J., Li, D., & Jin, Z. M. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914537476 · Cited by 73 · cited 2×
“Secondly, the open nature of the dataset and the fact that other groups have used the same dataset in their work to create musculoskeletal models creates the opportunity to compare results with other published research (Fregly et al. 2012; Chen et al. 2014).”
MethodResultA linear soft tissue artefact model for human movement analysis: Proof of concept using in vivo data
Andersen, M. S., Damsgaard, M., Rasmussen, J., Ramsey, D. K., & Benoit, D. L. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.032 · Cited by 69 · cited 1×
“However, Andersen et al. (2012) recently demonstrated that marker error caused by STA is neither random nor independent and 95% of the cumulative marker error caused by STA during gait could be modelled with a linear model containing only four parameters.”
BackgroundSelf-citationAli, N., Andersen, M. S., Rasmussen, J., Robertson, D. G. E., & Rouhi, G. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.758718 · Cited by 50 · cited 1×
“This kind of scaling approach have been used in numerous published studies that use musculoskeletal models (Rasmussen et al. 2012; Alkjaer et al. 2012; Ali et al. 2014; Oliveira et al. 2013; Chen et al. 2014).”
MethodSelf-citationEffects of Perturbations to Balance on Neuromechanics of Fast Changes in Direction during Locomotion
Oliveira, A. S., Silva, P. D. B., Lund, M. E., Gizzi, L., Farina, D., & Kersting, U. G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059029 · Cited by 44 · cited 1×
“This kind of scaling approach have been used in numerous published studies that use musculoskeletal models (Rasmussen et al. 2012; Alkjaer et al. 2012; Ali et al. 2014; Oliveira et al. 2013; Chen et al. 2014).”
MethodSelf-citation
Cited by
Altered Muscle Contributions are Required to Support the Stance Limb During Voluntary Toe-Walking
De Pieri, E., Romkes, J., Wyss, C., Brunner, R., & Viehweger, E. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.810560 · Cited by 12
Metadata
- Authors
- Lund, M. E., Andersen, M. S., de Zee, M., & Rasmussen, J.
- Venue
- International Biomechanics
- Publisher
- Informa UK Limited
- Published
- 2015-01
- Volume
- 2
- Issue
- 1
- Pages
- 1-11
- ISSN
- 2333-5432 (ISSN-L)
- OpenAlex
- W2154859335
- Cited by
- 176
- References
- 22
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.