The use of digital image correlation in the biomechanical area: a review
Open accessThe DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
This paper offers an overview of the potentialities and limitations of digital image correlation (DIC) as a technique for measuring displacements and strain in biomechanical applications. This review is mainly intended for biomechanists who are not yet familiar with DIC. This review includes over 150 papers and covers different dimensional scales, from the microscopic level (tissue level) up to macroscopic one (organ level). As DIC involves a high degree of computation, and of operator-dependent decisions, reliability of displacement and strain measurements by means of DIC cannot be taken for granted. Methodological problems and existing solutions are summarized and compared, whilst open issues are addressed. Topics addressed include: preparation methods for the speckle pattern on different tissues; software settings; systematic and random error associated with DIC measurement. Applications to hard and soft tissues at different dimensional scales are described and analyzed in terms of strengths and limitations. The potentialities and limitations of DIC are highlighted, also in comparison with other experimental techniques (strain gauges, other optical techniques, digital volume correlation) and numerical methods (finite element analysis), where synergies and complementarities are discussed. In order to provide an overview accessible to different scientists working in the field of biomechanics, this paper intentionally does not report details of the algorithms and codes used in the different studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schreier, H. W., Orteu, J., & Sutton, M. A. (2009) · Springer eBooks · doi:10.1007/978-0-387-78747-3 · Cited by 5,363
Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review
Pan, B., Qian, K., Xie, H., & Asundi, A. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/6/062001 · Cited by 3,166
Applications of digital-image-correlation techniques to experimental mechanics
Chu, T. C., Ranson, W. F., & Sutton, M. A. (1985) · Experimental Mechanics · doi:10.1007/bf02325092 · Cited by 2,236
Iterative Methods for Optimization
Kelley, C. T. (1999) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611970920 · Cited by 2,052
Determination of displacements using an improved digital correlation method
Sutton, M., Wolters, W., Peters, W., Ranson, W., & McNeill, Sr. (1983) · Image and Vision Computing · doi:10.1016/0262-8856(83)90064-1 · Cited by 1,927
Digital Imaging Techniques In Experimental Stress Analysis
Peters, W. H., & Ranson, W. F. (1982) · Optical Engineering · doi:10.1117/12.7972925 · Cited by 1,884
Digital image correlation using Newton-Raphson method of partial differential correction
Bruck, H. A., McNeill, S. R., Sutton, M. A., & Peters, W. H. (1989) · Experimental Mechanics · doi:10.1007/bf02321405 · Cited by 1,456
Smoothing noisy data with spline functions
Wahba, G. (1975) · Numerische Mathematik · doi:10.1007/bf01437407 · Cited by 1,443
Hild, F., & Roux, S. (2006) · Strain · doi:10.1111/j.1475-1305.2006.00258.x · Cited by 1,188
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142 · cited 2×
“For instance, the stiffness is computed as the ratio between the load and the displacement; bone remodelling is a well-known stress/ strain-driven process (Wolff’s law); bone fracture is governed by a strain-based failure criterion (Bayraktar et al. 2004).”
BackgroundDigital volume correlation: Three-dimensional strain mapping using X-ray tomography
Bay, B. K., Smith, T. S., Fyhrie, D. P., & Saad, M. (1999) · Experimental Mechanics · doi:10.1007/bf02323555 · Cited by 941
Journal of Biomedical Materials Research Part A
(2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/(issn)1552-4965 · Cited by 739
Luo, P. F., Chao, Y. J., Sutton, M. A., & Peters, W. H. (1993) · Experimental Mechanics · doi:10.1007/bf02322488 · Cited by 628
Systematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377
Verification and validation in computational engineering and science: basic concepts
Babuska, I., & Oden, J. T. (2004) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2004.03.002 · Cited by 376
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
Self-citationCoudrillier, B., Tian, J., Alexander, S., Myers, K. M., Quigley, H. A., & Nguyen, T. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8009 · Cited by 335
Study of optimal subset size in digital image correlation of speckle pattern images
Sun, Y., & Pang, J. H. L. (2007) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2007.01.012 · Cited by 319
Improved three-dimensional image correlation for surface displacement measurement
Helm, J. D., McNeill, S. R., & Sutton, M. A. (1996) · Optical Engineering · doi:10.1117/1.600624 · Cited by 312
Osteocyte lacunae tissue strain in cortical bone
Nicolella, D. P., Moravits, D. E., Gale, A. M., Bonewald, L. F., & Lankford, J. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.032 · Cited by 253
Strain rate and anisotropy effects on the tensile failure characteristics of human skin
Ottenio, M., Tran, D., Ní Annaidh, A., Gilchrist, M. D., & Bruyère, K. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.10.006 · Cited by 220
On optimal smoothing and derivative estimation from noisy displacement data in biomechanics
Woltring, H. J. (1985) · Human Movement Science · doi:10.1016/0167-9457(85)90004-1 · Cited by 215
Wang, C. C.-B., Deng, J.-M., Ateshian, G. A., & Hung, C. T. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1503795 · Cited by 205
de Bakker, P. M., Manske, S. L., Ebacher, V., Oxland, T. R., Cripton, P. A., & Guy, P. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.001 · Cited by 201
Full-field deformation of bovine cornea under constrained inflation conditions
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.011 · Cited by 191 · cited 2×
“Boyce, (Boyce et al. 2008)); (c) speckle pattern created with airbrush airgun technique, white-on-black, on a human achilles tendon (picture adapted from (luyckx et al.”
BackgroundMethodLiu, L., & Morgan, E. F. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.04.019 · Cited by 189
Lens distortion correction for digital image correlation by measuring rigid body displacement
Yoneyama, S., Kikuta, H., Kitagawa, A., & Kitamura, K. (2006) · Optical Engineering · doi:10.1117/1.2168411 · Cited by 173
Effect of microstructure on the mechanical properties of Haversian cortical bone
Hoc, T., Henry, L., Verdier, M., Aubry, D., Sedel, L., & Meunier, A. (2006) · Bone · doi:10.1016/j.bone.2005.09.017 · Cited by 173
Digital volume correlation including rotational degrees of freedom during minimization
Smith, T. S., Bay, B. K., & Rashid, M. M. (2002) · Experimental Mechanics · doi:10.1007/bf02410982 · Cited by 172
Moerman, K. M., Holt, C. A., Evans, S. L., & Simms, C. K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.02.016 · Cited by 172
Gillard, F., Boardman, R., Mavrogordato, M., Hollis, D., Sinclair, I., Pierron, F., & Browne, M. (2014) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.09.014 · Cited by 170
Sztefek, P., Vanleene, M., Olsson, R., Collinson, R., Pitsillides, A. A., & Shefelbine, S. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.10.042 · Cited by 161
Kelly, T. N., Ng, K., Wang, C. C. ‐., Ateshian, G. A., & Hung, C. T. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.03.031 · Cited by 160
Bay, B. K. (1995) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100130214 · Cited by 156
Wang, C. C. ‐., Chahine, N. O., Hung, C. T., & Ateshian, G. A. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00417-7 · Cited by 154
Stress-controlled viscoelastic tensile response of bovine cornea
Boyce, B. L., Jones, R. E., Nguyen, T. D., & Grazier, J. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.001 · Cited by 154
Evans, S. L., & Holt, C. A. (2009) · The Journal of Strain Analysis for Engineering Design · doi:10.1243/03093247jsa488 · Cited by 153
Roberts, B. C., Perilli, E., & Reynolds, K. J. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.01.001 · Cited by 150
Sutton, M. A., Ke, X., Lessner, S. M., et al. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31268 · Cited by 144
What do we currently know from in vivo bone strain measurements in humans?
Yang, P. F., Brüggemann, G.-P., & Rittweger, J. (2011) · PubMed · Cited by 143
Scleral anisotropy and its effects on the mechanical response of the optic nerve head
Coudrillier, B., Boote, C., Quigley, H. A., & Nguyen, T. D. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-012-0455-y · Cited by 133
Stereo-Digital Image Correlation (DIC) measurements with a single camera using a biprism
Genovese, K., Casaletto, L., Rayas, J. A., Flores-Muñoz, V. H., & Martínez, A. (2012) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2012.10.001 · Cited by 130
The distribution of strain in the human cornea
Shin, T. J., Vito, R. P., Johnson, L. W., & McCarey, B. E. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)84433-8 · Cited by 129
Digital Volume Correlation for Study of the Mechanics of Whole Bones
Hussein, A. I., Barbone, P. E., & Morgan, E. F. (2012) · Procedia IUTAM · doi:10.1016/j.piutam.2012.05.013 · Cited by 124
Nicolella, D. P., Nicholls, A. E., Lankford, J., & Davy, D. T. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00163-9 · Cited by 121
Sachs, C., Fabritius, H. O., & Raabe, D. (2006) · Journal of Structural Biology · doi:10.1016/j.jsb.2006.06.004 · Cited by 118
Dall’Ara, E., Barber, D. C., & Viceconti, M. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.07.019 · Cited by 108
Shear deformation and fracture of human cortical bone
Tang, T., Ebacher, V., Cripton, P. A., Guy, P., McKay, H. A., & Wang, R. (2014) · Bone · doi:10.1016/j.bone.2014.10.001 · Cited by 99
On the mechanical behavior of scales from Cyprinus carpio
Garrano, A. M. C., Rosa, G. L., Zhang, D., Niu, L., Tay, F. R., Majd, H., & Arola, D. D. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.07.017 · Cited by 96
Grassi, L., Väänänen, S. P., Yavari, S. A., Weinans, H., Jurvelin, J. S., ZADPOOR, A. A., & Isaksson, H. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.02.006 · Cited by 94
Palanca, M., Tozzi, G., Cristofolini, L., et al. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4030174 · Cited by 92
Self-citationDigital image correlation as a tool for three‐dimensional strain analysis in human tendon tissue
Luyckx, T., Verstraete, M., Roo, K. D., Waele, W. D., Bellemans, J., & Victor, J. M. K. (2014) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-014-0007-8 · Cited by 88
Juszczyk, M., Cristofolini, L., & Viceconti, M. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.05.038 · Cited by 82
Self-citationMeasurement of microstructural strain in cortical bone
Nicolella, D. P., Bonewald, L. F., Moravits, D. E., & Lankford, J. (2005) · European Journal of Morphology · doi:10.1080/09243860500095364 · Cited by 80
Mechanical testing of bones: the positive synergy of finite–element models and in vitro experiments
Cristofolini, L., Schileo, E., Juszczyk, M., Taddei, F., Martelli, S., & Viceconti, M. (2010) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2010.0046 · Cited by 80
Self-citationden Buijs, J. O., & Dragomir‐Daescu, D. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.11.008 · Cited by 78
Cox, M. A. J., Driessen, N. J. B., Boerboom, R. A., Bouten, C. V. C., & Baaijens, F. F. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.08.006 · Cited by 76
Lava, P., Coppieters, S., Wang, Y., Houtte, P. V., & Debruyne, D. (2010) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2010.08.017 · Cited by 62
Gilchrist, S., Guy, P., & Cripton, P. A. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025390 · Cited by 59
Structural behaviour and strain distribution of the long bones of the human lower limbs
Cristofolini, L., Conti, G., Juszczyk, M., Cremonini, S., Jan, S. V. S., & Viceconti, M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.11.022 · Cited by 59
Self-citationLocal Reinforcement Effect of a Strain Gauge Installation on Low Modulus Materials
Ajovalasit, A., & Zuccarello, B. (2005) · The Journal of Strain Analysis for Engineering Design · doi:10.1243/030932405x30894 · Cited by 59
Strain distribution in the proximal Human femur during in vitro simulated sideways fall
Zani, L., Erani, P., Grassi, L., Taddei, F., & Cristofolini, L. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.02.022 · Cited by 58
Self-citationLocal strain and damage mapping in single trabeculae during three-point bending tests
Jungmann, R., Szabo, M. E., Schitter, G., Yue-Sing Tang, R., Vashishth, D., Hansma, P. K., & Thurner, P. J. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.12.009 · Cited by 57 · cited 1×
“Single trabeculae of cancellous bone have been investigated with DIC and a high-speed camera in a three-point-bending test (Jungmann et al. 2011).”
MethodCyganik, Ł., Binkowski, M., Kokot, G., Rusin, T., Popik, P., Bolechała, F., Nowak, R., Wróbel, Z., & John, A. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.04.011 · Cited by 57
Helgason, B., Gilchrist, S. E., Ariza, O., Chak, J. D., Guoyan Zheng, A., Widmer, R. P., Ferguson, S. J., Guy, P., & Cripton, P. A. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.02.019 · Cited by 57
Methods for Examining the Fatigue and Fracture Behavior of Hard Tissues
Zhang, D., Nazari, A. Z., Soappman, M. J., Bajaj, D., & Arola, D. D. (2007) · Experimental Mechanics · doi:10.1007/s11340-006-9024-6 · Cited by 55
Baldoni, J., Lionello, G., Zama, F., & Cristofolini, L. (2016) · The Journal of Strain Analysis for Engineering Design · doi:10.1177/0309324716646690 · Cited by 48
Self-citationSoons, J. A. M., Lava, P., Debruyne, D., & Dirckx, J. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.05.004 · Cited by 43
Tiossi, R., Lin, L., Conrad, H. J., Rodrigues, R. C. S., Heo, Y. C., de Mattos, M. D. G. C., Fok, A. S. L., & Ribeiro, R. F. (2011) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2011.05.003 · Cited by 43
Measurement of Strain Distributions Within Vertebral Body Sections by Texture Correlation
Bay, B. K., Yerby, S. A., McLain, R. F., & Toh, E. (1999) · Spine · doi:10.1097/00007632-199901010-00004 · Cited by 39
Calibration of a Digital Image Correlation System
Sebastian, C. M., & Patterson, E. A. (2012) · Experimental Techniques · doi:10.1111/ext.12005 · Cited by 36
Strain distribution in the lumbar vertebrae under different loading configurations
Cristofolini, L., Brandolini, N., Danesi, V., Juszczyk, M., Erani, P., & Viceconti, M. (2013) · The Spine Journal · doi:10.1016/j.spinee.2013.06.014 · Cited by 35
Self-citationBiaxial mechanical properties of swine uterosacral and cardinal ligaments
Becker, W. R., & Vita, R. D. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-014-0621-5 · Cited by 35
Tendon Strain Measurements With Dynamic Ultrasound Images: Evaluation of Digital Image Correlation
Okotie, G., Duenwald-Kuehl, S. E., Kobayashi, H., Wu, M., & Vanderby, R. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006116 · Cited by 34
Trabecular bone strain changes associated with subchondral stiffening of the proximal tibia
McKinley, T. O., & Bay, B. K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00386-x · Cited by 34
Karimi, A., Navidbakhsh, M., Haghighatnama, M., & Haghi, A. M. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.961441 · Cited by 33
Ning, J., Xu, S., Wang, Y., Lessner, S. M., Sutton, M. A., Anderson, K., & Bischoff, J. E. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4002700 · Cited by 32
Benecke, G., Kerschnitzki, M., Fratzl, P., & Gupta, H. S. (2009) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2009.0064 · Cited by 30
Full-field strain measurement and fracture analysis of rat femora in compression test
Yavari, S. A., van der Stok, J., Weinans, H., & ZADPOOR, A. A. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.02.007 · Cited by 30
Presence of intervertebral discs alters observed stiffness and failure mechanisms in the vertebra
Hussein, A. I., Mason, Z. D., & Morgan, E. F. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.04.004 · Cited by 26
Transport of Neutral Solute Across Articular Cartilage: The Role of Zonal Diffusivities
Arbabi, V., Pouran, B., Weinans, H., & ZADPOOR, A. A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4030070 · Cited by 25
Cited by
Pan, B. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aac55b · Cited by 887
MultiDIC: An Open-Source Toolbox for Multi-View 3D Digital Image Correlation
Solav, D., Moerman, K. M., Jaeger, A. M., Genovese, K., & Herr, H. M. (2018) · IEEE Access · doi:10.1109/access.2018.2843725 · Cited by 219
“DIC methods have been used in combination with advanced inverse characterization methods to identify the mechanical properties of natural and synthetic biological materials and body parts [5]–[8].”
MethodYang, R., Li, Y., Zeng, D., & Guo, P. (2022) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2021.117474 · Cited by 207
“…applied in experimental solid mechanics to accurately measure two-dimensional (2D) and three-dimensional (3D) displacement and strain fields in various material systems (Pan et al., 2009), including engineering metals, polymers (Jerabek et al., 2010), and even bio-materials (Palanca et al., 2016).”
BackgroundMaiti, R., Gerhardt, L.-C., Lee, Z. S., Byers, R. A., Woods, D., Sanz-Herrera, J. A., Franklin, S. E., Lewis, R., Matcher, S. J., & Carré, M. J. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.05.035 · Cited by 193
Metadata
- Authors
- Palanca, M., Tozzi, G., & Cristofolini, L.
- Venue
- International Biomechanics
- Publisher
- Informa UK Limited
- Published
- 2015-12-21
- Volume
- 3
- Issue
- 1
- Pages
- 1-21
- ISSN
- 2333-5432 (ISSN-L)
- OpenAlex
- W2226468791
- Cited by
- 304
- References
- 81
- FWCI
- 10.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.