The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
The cytomechanics of axonal elongation and retraction.
Open accessAbstract
Neurites of PC12 and chick dorsal root ganglion neurons behave as viscoelastic solids in response to applied forces. This passive behavior can be modeled with three mechanical elements; a relatively stiff, undamped spring in series with a Voight element composed of a less stiff spring in parallel with a dashpot. In response to applied tensions greater than 100 microdynes, PC12 cells show lengthening behavior distinct from and in addition to the passive viscoelastic response. We interpret this as "towed growth" (Bray, D. 1984. Dev. Biol. 102:379-389) because the neurites can become twice as long without obvious thinning of the neurite and because in two cases neurite tensions fell below original rest tensions, a result that cannot be obtained with passive viscoelastic elements. The rate of towed growth showed a linear dependence of growth rate with applied tensions in 8 of 12 PC12 neurites exposed to applied tension greater than 100 microdynes. Both PC12 and chick sensory neurons showed evidence of retraction when neurite tensions were suddenly diminished. This response was measured as tension recovery after slackening in chick sensory neurites. In 62% of the cases, tension recovery exceeded and sometimes doubled the preexperimental steady-state tension. Our data indicate that this response is active tension generation by the neurite shaft. We conclude that neurite length is regulated by axial tension in both elongation and retraction. Our data suggest a three-way controller: above some tension set point, the neurite is stimulated to elongate. Below some different, lower tension threshold the neurite is stimulated to retract. Between these two tension thresholds, the neurite responds passively as a viscoelastic solid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Promotion of microtubule assembly in vitro by taxol
SCHIFF, P. B., FANT, J., & HORWITZ, S. B. (1979) · Nature · doi:10.1038/277665a0 · Cited by 3,600
Regressive Events in Neurogenesis
Cowan, W. M., Fawcett, J. W., O'Leary, D. D. M., & Stanfield, B. B. (1984) · Science · doi:10.1126/science.6474175 · Cited by 1,316
Cytoskeletal dynamics and nerve growth
Mitchison, T., & Kirschner, M. (1988) · Neuron · doi:10.1016/0896-6273(88)90124-9 · Cited by 871
Elimination of synapses in the developing nervous system
Purves, D., & Lichtman, J. W. (1980) · Science · doi:10.1126/science.7414326 · Cited by 808
Hirokawa, N. (1982) · The Journal of Cell Biology · doi:10.1083/jcb.94.1.129 · Cited by 671
Principles of neural development
(1985) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(85)90519-5 · Cited by 630
Axonal growth in response to experimentally applied mechanical tension
Bray, D. (1984) · Developmental Biology · doi:10.1016/0012-1606(84)90202-1 · Cited by 369
Direct evidence that growth cones pull
Lamoureux, P., Buxbaum, R. E., & Heidemann, S. R. (1989) · Nature · doi:10.1038/340159a0 · Cited by 297
Self-citationRich, M., & Lichtman, J. (1989) · The Journal of Neuroscience · doi:10.1523/jneurosci.09-05-01781.1989 · Cited by 291
Tension and compression in the cytoskeleton of PC-12 neurites. II: Quantitative measurements.
Dennerll, T. J., Joshi, H. C., Steel, V. L., Buxbaum, R. E., & Heidemann, S. R. (1988) · The Journal of cell biology · doi:10.1083/jcb.107.2.665 · Cited by 285
Self-citation
Cited by
Flexural rigidity of microtubules and actin filaments measured from thermal fluctuations in shape.
Gittes, F., Mickey, B., Nettleton, J., & Howard, J. (1993) · The Journal of cell biology · doi:10.1083/jcb.120.4.923 · Cited by 1,817
A tension-based theory of morphogenesis and compact wiring in the central nervous system
Essen, D. C. V. (1997) · Nature · doi:10.1038/385313a0 · Cited by 1,683
Tensegrity I. Cell structure and hierarchical systems biology
Ingber, D. E. (2003) · Journal of Cell Science · doi:10.1242/jcs.00359 · Cited by 1,265
Cellular tensegrity: defining new rules of biological design that govern the cytoskeleton
Ingber, D. E. (1993) · Journal of Cell Science · doi:10.1242/jcs.104.3.613 · Cited by 1,155
Tensegrity II. How structural networks influence cellular information processing networks
Ingber, D. E. (2003) · Journal of Cell Science · doi:10.1242/jcs.00360 · Cited by 839
Metadata
- Authors
- Dennerll, T. J., Lamoureux, P., Buxbaum, R. E., & Heidemann, S. R.
- Venue
- The Journal of cell biology
- Publisher
- Rockefeller University Press
- Published
- 1989-12-01
- Volume
- 109
- Issue
- 6
- Pages
- 3073-3083
- ISSN
- 0021-9525 (ISSN-L)
- 1540-8140
- OpenAlex
- W2130358104
- Cited by
- 263
- References
- 30
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The cytomechanics of axonal elongation and retraction. https://app.cochat.ai/papers/10.1083/jcb.109.6.3073
- The paper
- Dennerll, T. J., Lamoureux, P., Buxbaum, R. E., & Heidemann, S. R. (1989). The cytomechanics of axonal elongation and retraction. The Journal of cell biology. https://doi.org/10.1083/jcb.109.6.3073
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.