The structure and dynamics of patch-clamped membranes: a study using differential interference contrast light microscopy.
Open accessThe DOI matches its Crossref record.
Abstract
We have developed techniques for micromanipulation under high power video microscopy. We have used these to study the structure and motion of patch-clamped membranes when driven by pressure steps. Patch-clamped membranes do not consist of just a membrane, but rather a plug of membrane-covered cytoplasm. There are organelles and vesicles within the cytoplasm in the pipette tip of both cell-attached and excised patches. The cytoplasm is capable of active contraction normal to the plane of the membrane. With suction applied before seal formation, vesicles may be swept from the cell surface by shear stress generated from the flow of saline over the cell surface. In this case, patch recordings are made from membrane that was not originally present under the tip. The vesicles may break, or fuse and break, to form the gigasealed patch. Patch membranes adhere strongly to the wall of the pipette so that at zero transmural pressure the membranes tend to be normal to the wall. With transmural pressure gradients, the membranes generally become spherical; the radius of curvature decreasing with increasing pressure. Some patches have nonuniform curvature demonstrating that forces normal to the membrane may be significant. Membranes often do not respond quickly to changes in pipette pressure, probably because viscoelastic cytoplasm reduces the rate of flow through the tip of the pipette. Inside-out patches may be peeled from the walls of the pipette, and even everted (with positive pressure), without losing the seal. This suggests that the gigaseal is a distributed property of the membrane-glass interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular Basis of Mechanotransduction in Living Cells
Hamill, O. P., & Martinac, B. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.2.685 · Cited by 1,134
Mechanically Activated Ion Channels
Ranade, S. S., Syeda, R., & Patapoutian, A. (2015) · Neuron · doi:10.1016/j.neuron.2015.08.032 · Cited by 652
“It has been long postulated and later established that mechanosensitive channels respond to mechanical forces along the plane of the cell membrane for example membrane tension but not to hydrostatic pressure perpendicular to it (Sokabe and Sachs, 1990; Sokabe et al., 1991).”
Mechanosensitive ion channels: molecules of mechanotransduction
Martinac, B. (2004) · Journal of Cell Science · doi:10.1242/jcs.01232 · Cited by 556
Cox, C. D., Bae, C., Ziegler, L., Hartley, S., Nikolova-Krstevski, V., Rohde, P. R., Ng, C.-A., Sachs, F., Gottlieb, P. A., & Martinac, B. (2016) · Nature Communications · doi:10.1038/ncomms10366 · Cited by 528
Self-citationCalcium-induced actin depolymerization reduces NMDA channel activity
Rosenmund, C., & Westbrook, G. L. (1993) · Neuron · doi:10.1016/0896-6273(93)90197-y · Cited by 503
Adenosine triphosphate-sensitive potassium channels in the cardiovascular system
Nichols, C. G., & Lederer, W. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.261.6.h1675 · Cited by 437
Stretch-Activated Ion Channels: What Are They?
Sachs, F. (2010) · Physiology · doi:10.1152/physiol.00042.2009 · Cited by 308
Self-citationMECHANOSENSITIVE CHANNELS OF ESCHERICHIA COLI:The MscL Gene, Protein, and Activities
Sukharev, S. I., Blount, P., Martinac, B., & Kung, A. C. (1997) · Annual Review of Physiology · doi:10.1146/annurev.physiol.59.1.633 · Cited by 299
Three types of sodium channels in adult rat dorsal root ganglion neurons
Caffrey, J. M., Eng, D. L., Black, J. A., Waxman, S. G., & Kocsis, J. D. (1992) · Brain Research · doi:10.1016/0006-8993(92)91687-a · Cited by 297
OSMORECEPTORS IN THE CENTRAL NERVOUS SYSTEM
Bourque and, C. W., & Oliet, S. H. R. (1997) · Annual Review of Physiology · doi:10.1146/annurev.physiol.59.1.601 · Cited by 293
Naruse, K., & Sokabe, M. (1993) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1993.264.4.c1037 · Cited by 283
Self-citationCruickshank, C. C., Minchin, R. F., Le Dain, A. C., & Martinac, B. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78223-7 · Cited by 262
Sokabe, M., Sachs, F., & Jing, Z. Q. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82285-8 · Cited by 254
Self-citationMechanosensory calcium‐selective cation channels in epidermal cells
Ding, J. P., & Pickard, B. G. (1993) · The Plant Journal · doi:10.1046/j.1365-313x.1993.t01-4-00999.x · Cited by 254
Yao, Y., Ferrer-Montiel, A. V., Montal, M., & Tsien, R. Y. (1999) · Cell · doi:10.1016/s0092-8674(00)81976-5 · Cited by 242
BERRIER, C., COULOMBE, A., SZABO, I., ZORATTI, M., & GHAZI, A. (1992) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1992.tb16960.x · Cited by 201
Moe, P., & Blount, P. (2005) · Biochemistry · doi:10.1021/bi0509649 · Cited by 201
Biophysics and Structure of the Patch and the Gigaseal
Suchyna, T. M., Markin, V. S., & Sachs, F. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.05.018 · Cited by 177
Self-citation
Metadata
- Authors
- Sokabe, M., & Sachs, F.
- Venue
- The Journal of cell biology
- Publisher
- Rockefeller University Press
- Published
- 1990-08-01
- Volume
- 111
- Issue
- 2
- Pages
- 599-606
- ISSN
- 0021-9525 (ISSN-L)
- 1540-8140
- OpenAlex
- W2073149428
- Cited by
- 124
- References
- 0
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.