Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 1,072

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

HIGH-RESOLUTION AUTORADIOGRAPHY

Open access
Caro, Lucien G., van Tubergen, Robert P. · 1962 · The Journal of Cell Biology

Abstract

Methods used in obtaining high resolution in autoradiography, with special emphasis on the technique of electron microscopic autoradiography, are described, together with control experiments designed to establish the optimum conditions or procedures. On the basis of these experiments the emulsion selected was Ilford L-4, with a crystal size slightly larger than 0.1 micron. It is applied to the specimen in the form of a gelled film consisting of a monolayer of silver halide crystals. Background, when present, can be eradicated by a simple method. The preparations can be stored, in presence of a drying agent, at room temperature or in a refrigerator. Photographic development is done in Microdol, or in a special fine grain "physical" developer. For examination in the electron microscope the sections are stained with uranyl or lead stains. These methods give a good localization of the label, at the subcellular level, and good reproducibility in relative grain counts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1083/jcb.15.2.173

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Caro, L. G., & van Tubergen, R. P.
Venue
The Journal of Cell Biology
Published
1962-11-01
Volume
15
Issue
2
Pages
173-188
ISSN
  • 0021-9525 (ISSN-L)
  • 1540-8140
OpenAlex
W1973243290
Cited by
1,072
References
3
FWCI
25.70
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.