CoChat

Microtubule cross-linking triggers the directional motility of kinesin-5

Open access

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Although assembly of the mitotic spindle is known to be a precisely controlled process, regulation of the key motor proteins involved remains poorly understood. In eukaryotes, homotetrameric kinesin-5 motors are required for bipolar spindle formation. Eg5, the vertebrate kinesin-5, has two modes of motion: an adenosine triphosphate (ATP)–dependent directional mode and a diffusive mode that does not require ATP hydrolysis. We use single-molecule experiments to examine how the switching between these modes is controlled. We find that Eg5 diffuses along individual microtubules without detectable directional bias at close to physiological ionic strength. Eg5's motility becomes directional when bound between two microtubules. Such activation through binding cargo, which, for Eg5, is a second microtubule, is analogous to known mechanisms for other kinesins. In the spindle, this might allow Eg5 to diffuse on single microtubules without hydrolyzing ATP until the motor is activated by binding to another microtubule. This mechanism would increase energy and filament cross-linking efficiency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1083/jcb.200801145

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Full-length Eg5 motility on single microtubules depends on ionic strength. (A and B) Frames (A) and kymograph (B) from a time-lapse recording showing single molecules of Eg5-GFP (green) moving directionally along a microtubule (red) in the presence of 70 mM Pipes. (C and D) Frames (C) and kymograph (D) from a time-lapse recording showing single molecules of Eg5-GFP (green) diffusing along a microtubule (red) in the presence of 70 mM Pipes plus 40 mM KCl. (E–H) MD calculated from Eg5-GFP motility in the presence of ATP (black) and ADP (red) in 70 mM Pipes plus 0, 20, 40, or 60 mM KCl. Fits represent MD = vτ. (I–M) MSD calculated from Eg5-GFP motility in the presence of ATP (black) and ADP (red) and at the indicated ionic strengths. Fits represent MD = vτ and MD = v2τ2 + 2Dτ + offset for the ATP data and MD = 2Dτ + offset for the ADP data. All numerical results are listed in Table I. (N) Histogram of the duration of binding events for 0 mM KCl and for 60 mM KCl added. Lines are single exponential fits (exp[−t/tav]) to the data (0 mM: tav = 34 ± 3, n = 212; 60 mM: tav = 16 ± 2, n = 119). Error bars represent SD. Bars, 1 μm.
Figure 1. Full-length Eg5 motility on single microtubules depends on ionic strength. (A and B) Frames (A) and kymograph (B) from a time-lapse recording showing single molecules of Eg5-GFP (green) moving directionally along a microtubule (red) in the presence of 70 mM Pipes. (C and D) Frames (C) and kymograph (D) from a time-lapse recording showing single molecules of Eg5-GFP (green) diffusing along a microtubule (red) in the presence of 70 mM Pipes plus 40 mM KCl. (E–H) MD calculated from Eg5-GFP motility in the presence of ATP (black) and ADP (red) in 70 mM Pipes plus 0, 20, 40, or 60 mM KCl. Fits represent MD = vτ. (I–M) MSD calculated from Eg5-GFP motility in the presence of ATP (black) and ADP (red) and at the indicated ionic strengths. Fits represent MD = vτ and MD = v2τ2 + 2Dτ + offset for the ATP data and MD = 2Dτ + offset for the ADP data. All numerical results are listed in Table I. (N) Histogram of the duration of binding events for 0 mM KCl and for 60 mM KCl added. Lines are single exponential fits (exp[−t/tav]) to the data (0 mM: tav = 34 ± 3, n = 212; 60 mM: tav = 16 ± 2, n = 119). Error bars represent SD. Bars, 1 μm.CC BY-NC-SA · PubMed Central
Figure 2. Dimeric Eg5 exhibits persistent microtubule association only at ionic strength well below physiological conditions. (A) Kymograph of the displacement of 230 pM Eg5-513-GFP dimers versus time in 80 mM Pipes buffer with 0.2 mM ATP. A large majority of binding events last two frames or less (<2 s). Similar results were obtained at 2 mM ATP (not depicted). (B) Kymographs showing processive runs by 14 pM Eg5-513-GFP dimers in 20 mM Pipes with 2 mM ATP. Bars, 2 μm.
Figure 2. Dimeric Eg5 exhibits persistent microtubule association only at ionic strength well below physiological conditions. (A) Kymograph of the displacement of 230 pM Eg5-513-GFP dimers versus time in 80 mM Pipes buffer with 0.2 mM ATP. A large majority of binding events last two frames or less (<2 s). Similar results were obtained at 2 mM ATP (not depicted). (B) Kymographs showing processive runs by 14 pM Eg5-513-GFP dimers in 20 mM Pipes with 2 mM ATP. Bars, 2 μm.CC BY-NC-SA · PubMed Central
Figure 3. Full-length Eg5 motility at high ionic strength is directional on microtubule bundles (axonemes). (A) Cartoon of a possible interaction geometry of Eg5 with microtubule bundles. Note that Eg5 has a length of ∼80 nm (Kashina et al., 1996), and an axoneme has a diameter of 200 nm, with microtubule doublets being ∼70 nm apart (Alberts et al., 2002). (B) Kymographs of Eg5-GFP motility versus time on an axoneme in the presence of ATP. (C) MD calculated from motility recordings in the presence of ATP. Fit represents MD = vτ (v = 23 nm/s). (D) MSD calculated from different motility recordings in the presence of ATP (black) or ADP (red). Fit for ATP represents MD = v2τ2 + 2Dτ (v = 26 nm/s; D = 1.8 × 103 nm2/s). Fit for ADP represents MD = 2Dτ (D = 1.3 × 103 nm2/s). Error bars represent SD. Bar, 1 μm.
Figure 3. Full-length Eg5 motility at high ionic strength is directional on microtubule bundles (axonemes). (A) Cartoon of a possible interaction geometry of Eg5 with microtubule bundles. Note that Eg5 has a length of ∼80 nm (Kashina et al., 1996), and an axoneme has a diameter of 200 nm, with microtubule doublets being ∼70 nm apart (Alberts et al., 2002). (B) Kymographs of Eg5-GFP motility versus time on an axoneme in the presence of ATP. (C) MD calculated from motility recordings in the presence of ATP. Fit represents MD = vτ (v = 23 nm/s). (D) MSD calculated from different motility recordings in the presence of ATP (black) or ADP (red). Fit for ATP represents MD = v2τ2 + 2Dτ (v = 26 nm/s; D = 1.8 × 103 nm2/s). Fit for ADP represents MD = 2Dτ (D = 1.3 × 103 nm2/s). Error bars represent SD. Bar, 1 μm.CC BY-NC-SA · PubMed Central
Figure 4. Eg5-GFP–driven relative sliding of microtubules. (A) Cartoon illustrating assay. A sparsely labeled microtubule is surface attached, whereas another microtubule binds with an antiparallel orientation and is moved by Eg5 homotetramers. (B and C) Top kymographs show sliding of a microtubule relative to a surface-attached microtubule at 35 (B) and 28 nm/s (C). Below, corresponding kymographs of Eg5-GFP show directional runs (∼25 [B] and ∼13 nm/s [C]) between two overlapping microtubules (region marked with two red dotted lines) and diffusive motility in regions without overlap. The slope of the arrows indicate the velocity of motors (green) or microtubules (red). Bars, 2 μm.
Figure 4. Eg5-GFP–driven relative sliding of microtubules. (A) Cartoon illustrating assay. A sparsely labeled microtubule is surface attached, whereas another microtubule binds with an antiparallel orientation and is moved by Eg5 homotetramers. (B and C) Top kymographs show sliding of a microtubule relative to a surface-attached microtubule at 35 (B) and 28 nm/s (C). Below, corresponding kymographs of Eg5-GFP show directional runs (∼25 [B] and ∼13 nm/s [C]) between two overlapping microtubules (region marked with two red dotted lines) and diffusive motility in regions without overlap. The slope of the arrows indicate the velocity of motors (green) or microtubules (red). Bars, 2 μm.CC BY-NC-SA · PubMed Central
Figure 5. Full-length Eg5-GFP switches from diffusive to directional motility upon binding to a second microtubule. Data collected as described in Fig. 4, but in the presence of a mixture of 1 nM Eg5-GFP and 2 nM of unlabeled tetrameric Eg5. (A) Top kymograph shows sliding of a microtubule (MT) relative to a surface-attached microtubule. Below, the corresponding kymograph of Eg5-GFP shows directional runs between the overlapping microtubules (region marked with two red dotted lines). (B–F) Analysis of Eg5 motility during relative sliding. (B) Scatter plot of all pairs of short-term velocity and diffusion constant determined for a window of 15 s moving over the composite position-time trace of 94 Eg5 motors traced in the overlap zone of 11 microtubule pairs (2,335 points obtained from 2,349 s of total time). The horizontal dotted line indicates the average velocity of sliding microtubules (33 nm/s), and the vertical dotted line indicates the threshold used to discriminate slow and fast diffusion. (C and D) Similar analyses for Eg5 moving on individual microtubules at low ionic strength (C, 70 mM Pipes; Fig. 1; 4,266 points) and high ionic strength (D, data pooled from 70 mM Pipes + 60 mM KCl and 70 mM Pipes + 80 mM KCl; 2,478 points). (E) Position-time traces. Black, fraction of the composite trace used for B. Green and red, sorted time points with a short-term diffusion constant; D < 1,500 nm2/s (green) and D >1,500 nm2/s (red). (F) Histograms of the short-term velocities as obtained from the time points in the green and red trace in E. The arrow indicates the average microtubule sliding velocity. (G) Graph summarizing Eg5 behavior under various conditions. Bar, 2 μm.
Figure 5. Full-length Eg5-GFP switches from diffusive to directional motility upon binding to a second microtubule. Data collected as described in Fig. 4, but in the presence of a mixture of 1 nM Eg5-GFP and 2 nM of unlabeled tetrameric Eg5. (A) Top kymograph shows sliding of a microtubule (MT) relative to a surface-attached microtubule. Below, the corresponding kymograph of Eg5-GFP shows directional runs between the overlapping microtubules (region marked with two red dotted lines). (B–F) Analysis of Eg5 motility during relative sliding. (B) Scatter plot of all pairs of short-term velocity and diffusion constant determined for a window of 15 s moving over the composite position-time trace of 94 Eg5 motors traced in the overlap zone of 11 microtubule pairs (2,335 points obtained from 2,349 s of total time). The horizontal dotted line indicates the average velocity of sliding microtubules (33 nm/s), and the vertical dotted line indicates the threshold used to discriminate slow and fast diffusion. (C and D) Similar analyses for Eg5 moving on individual microtubules at low ionic strength (C, 70 mM Pipes; Fig. 1; 4,266 points) and high ionic strength (D, data pooled from 70 mM Pipes + 60 mM KCl and 70 mM Pipes + 80 mM KCl; 2,478 points). (E) Position-time traces. Black, fraction of the composite trace used for B. Green and red, sorted time points with a short-term diffusion constant; D < 1,500 nm2/s (green) and D >1,500 nm2/s (red). (F) Histograms of the short-term velocities as obtained from the time points in the green and red trace in E. The arrow indicates the average microtubule sliding velocity. (G) Graph summarizing Eg5 behavior under various conditions. Bar, 2 μm.CC BY-NC-SA · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Research works printed but not linked: 1

  1. 1991, J. Cell Sci. Suppl., 14, 125

Cited by

Items 101–143 of 143

Metadata

Authors
Kapitein, L. C., Kwok, B. H., Weinger, J. S., Schmidt, C. F., Kapoor, T. M., & Peterman, E. J. G.
Affiliations
  • Erasmus MC (NL)
  • Rockefeller University (US)
  • University of Göttingen (DE)
  • 1Department of Physics and Astronomy
Venue
The Journal of Cell Biology
Published
2008-08-04
Volume
182
Issue
3
Pages
421-428
ISSN
  • 0021-9525 (ISSN-L)
  • 1540-8140
OpenAlex
W2015281071
Cited by
143
References
28
Citations by year
2026: 1 · 2024: 7 · 2023: 3 · 2022: 3 · 2021: 10 · 2020: 6 · 2019: 2 · 2018: 8 · 2017: 4 · 2016: 10 · 2015: 9 · 2014: 10 · 2013: 11 · 2012: 7
FWCI
7.14
Type
journal article
Language
en
Open access
Licence
cc-by-nc-sa
Locations
  • The Journal of Cell Biology (publishedVersion, cc-by-nc-sa)
  • PubMed Central (publishedVersion, cc-by-nc-sa)
  • PubMed (publishedVersion)
  • RePub (Erasmus University Rotterdam) (submittedVersion, other-oa)
  • Digital Academic REpository of VU University Amsterdam (Vrije Universiteit Amsterdam) (submittedVersion)
  • GRO (submittedVersion)
  • RePub (Erasmus University Rotterdam) (submittedVersion)
  • VU Research Portal (submittedVersion, other-oa)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
Funders
  • Deutsche Forschungsgemeinschaft
  • Erasmus Medisch Centrum
  • National Institutes of Health
  • National Cancer Institute (T32CA009673)
  • National Institute of General Medical Sciences (R01GM065933, GM65933)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Microtubule and mitosis dynamics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
Keywords
kinesin-5, Eg5, microtubule crosslinking, directional motility, mitotic spindle assembly, bipolar spindle formation, microtubule binding, single-molecule motility
MeSH terms
Animals, Diffusion, Microtubules, Osmolar Concentration, Recombinant Fusion Proteins, Swine, Xenopus, Kinesins, Dimerization, Protein Structure, Quaternary, Protein Transport, Xenopus Proteins, Green Fluorescent Proteins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.