The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
AN ULTRASENSITIVE VIBRATING PROBE FOR MEASURING STEADY EXTRACELLULAR CURRENTS
Open accessAbstract
We describe a vibrating probe system for measuring relatively steady electrical current densities near individual living cells. It has a signal-to-noise ratio at least 100 times greater than previously available techniques. Thus it can be used to detect current densities as small as 10 nA/cm2 in serum when a 30-µm diameter probe is vibrated at 200 Hz between two points 30 µm apart, and the amplifier's time constant is set at 10 s. Moreover, it should be generally insensitive to interference by concentration gradients. It has been first used to reveal and study 100-s long current pulses which developing fucoid embryos drive through themselves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 19,877
Tranter, C. J. (1959) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(59)90029-8 · Cited by 18,388
Davies, J. T., Rideal, E. K., & Bender, M. (1962) · Journal of The Electrochemical Society · doi:10.1149/1.2425494 · Cited by 1,059
Cole, K. S. (1968) · University of California Press eBooks · doi:10.1525/9780520326514 · Cited by 992
Dark Current and Photocurrent in Retinal Rods
Hagins, W. A., Penn, R. D., & Yoshikami, S. (1970) · Biophysical Journal · doi:10.1016/s0006-3495(70)86308-1 · Cited by 556
Gesteland, R. C., Howland, B., Lettvin, J. Y., & Pitts, W. H. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287156 · Cited by 301
LUND, E. J. (1947) · Soil Science · doi:10.1097/00010694-194709000-00010 · Cited by 248
Enderle, J. D. (2012) · Introduction to Biomedical Engineering · doi:10.1016/b978-0-12-374979-6.00012-5 · Cited by 216
PHYSICAL TECHNIQUES IN BIOLOGICAL RESEARCH
(1963) · Elsevier eBooks · doi:10.1016/b978-1-4831-6743-5.50006-x · Cited by 142
Cole, K. S. (2023) · University of California Press eBooks · doi:10.2307/jj.8501406 · Cited by 84
ELECTROPHORETIC THEORY OF PIGMENT MIGRATION WITHIN FISH MELANOPHORE
Kinosita, H. (1963) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1963.tb42946.x · Cited by 41
Cited by
Electrical signals control wound healing through phosphatidylinositol-3-OH kinase-γ and PTEN
Zhao, M., Song, B., Pu, J., Wada, T., Reid, B., Tai, G., Wang, F., Guo, A., Walczysko, P., Gu, Y., et al. (2006) · Nature · doi:10.1038/nature04925 · Cited by 1,167
Controlling Cell Behavior Electrically: Current Views and Future Potential
McCaig, C. D., Rajnicek, A. M., Song, B., & Zhao, M. (2005) · Physiological Reviews · doi:10.1152/physrev.00020.2004 · Cited by 1,096
Measurement of Intracellular Calcium
Takahashi, A., Camacho, P., Lechleiter, J. D., & Herman, B. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.4.1089 · Cited by 763
Electrical fields in wound healing—An overriding signal that directs cell migration
Zhao, M. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2008.12.009 · Cited by 714
Electrolyte transport in the mammalian colon: mechanisms and implications for disease
Kunzelmann, K., & Mall, M. (2002) · Physiological Reviews · doi:10.1152/physrev.00026.2001 · Cited by 655
Metadata
- Authors
- Jaffe, L. F., & Nuccitelli, R.
- Venue
- The Journal of Cell Biology
- Publisher
- Rockefeller University Press
- Published
- 1974-11-01
- Volume
- 63
- Issue
- 2
- Pages
- 614-628
- ISSN
- 0021-9525 (ISSN-L)
- 1540-8140
- OpenAlex
- W2039900497
- Cited by
- 525
- References
- 11
- FWCI
- 8.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.