CoChat

Differential effects of Ba2+, Sr2+, and Ca2+ on stimulation-induced changes in transmitter release at the frog neuromuscular junction.

Open access
Zengel, J E, Magleby, K L · 1980 · The Journal of general physiology
Cited by 74

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Endplate potentials (EPP) were recorded from the frog sartorius neuromuscular junction under conditions of low quantal content to study the effect of Ba2+, Sr2+, and Ca2+ on the changes in evoked transmitter release that occur during and after repetitive stimulation. The addition of 0.1-1 mM Ba2+ or Sr2+ to the Ca2+-containing bathing solution, or the replacement of Ca2+ with 0.8-1.4 mM Sr2+, led to a greater increase in EPP amplitudes during and immediately after repetitive stimulation. These changes in release were analyzed in terms of the four apparent components of increased transmitter release that have previously been distinguished on the basis of their kinetic properties. The Ba2+-induced increase in EPP amplitudes was associated with an increase in the magnitude but not the time constant of decay of augmentation. Ba2+ had little effect on potentiation or the first and second components of facilitation. The Sr2+-induced increase in EPP amplitudes was associated with an increase in the magnitude and the time constant of decay of the second component of facilitation. Sr2+ had little effect on potentiation, augmentation, or the first component of facilitation. The selective effects of Ba2+ on augmentation and of Sr2+ on the second component of facilitation were reversible and could be obtained in the presence of the other ion. The addition of 0.1-0.3 mM Ca2+ to the bathing solution had little effect on potentiation, augmentation, or the two components of facilitation. These results provide pharmacological support for the proposal that there are four different components of increased transmitter release associated with repetitive stimulation and suggest that the underlying factors in the nerve terminal that give rise to these components can act somewhat independently of one another.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1085/jgp.76.2.175

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Zengel, J. E., & Magleby, K. L.
Venue
The Journal of general physiology
Published
1980-08-01
Volume
76
Issue
2
Pages
175-211
ISSN
  • 0022-1295 (ISSN-L)
  • 1540-7748
OpenAlex
W2144497288
Cited by
74
References
1
FWCI
1.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.