The DOI matches its Crossref record.
Two components of cardiac delayed rectifier K+ current. Differential sensitivity to block by class III antiarrhythmic agents.
Open accessAbstract
An envelope of tails test was used to show that the delayed rectifier K+ current (IK) of guinea pig ventricular myocytes results from the activation of two outward K+ currents. One current was specifically blocked by the benzenesulfonamide antiarrhythmic agent, E-4031 (IC50 = 397 nM). The drug-sensitive current, "IKr" exhibits prominent rectification and activates very rapidly relative to the slowly activating drug-insensitive current, "IKs." IKs was characterized by a delayed onset of activation that occurs over a voltage range typical of the classically described cardiac IK. Fully activated IKs, measured as tail current after 7.5-s test pulses, was 11.4 times larger than the fully activated IKr. IKr was also blocked by d-sotalol (100 microM), a less potent benzenesulfonamide Class III antiarrhythmic agent. The activation curve of IKr had a steep slope (+7.5 mV) and a negative half-point (-21.5 mV) relative to the activation curve of IKs (slope = +12.7 mV, half-point = +15.7 mV). The reversal potential (Erev) of IKr (-93 mV) was similar to EK (-94 mV for [K+]o = 4 mM), whereas Erev of IKs was -77 mV. The time constants for activation and deactivation of IKr made up a bell-shaped function of membrane potential, peaking between -30 and -40 mV (170 ms). The slope conductance of the linear portion of the fully activated IKr-V relation was 22.5 S/F. Inward rectification of this relation occurred at potentials greater than -50 mV, resulting in a voltage-dependent decrease in peak IKr at test potentials greater than 0 mV. Peak IKr at 0 mV averaged 0.8 pA/pF (n = 21). Although the magnitude of IKr was small relative to fully activated IKs, the two currents were of similar magnitude when measured during a relatively short pulse protocol (225 ms) at membrane potentials (-20 to +20 mV) typical of the plateau phase of cardiac action potentials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
O'Hara, T., Virág, L., Varró, A., & Rudy, Y. (2011) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002061 · Cited by 1,196
Molecular Diversity of K+ Channels
COETZEE, W. A., AMARILLO, Y., CHIU, J., CHOW, A., LAU, D., McCORMACK, T., MORENA, H., NADAL, M. S., OZAITA, A., POUNTNEY, D., et al. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb11293.x · Cited by 1,095
Sudden death associated with short-QT syndrome linked to mutations in HERG
Brugada, R., Hong, K., Dumaine, R., Cordeiro, J., Gaita, F., Borggrefe, M., Menendez, T. M., Brugada, J., Pollevick, G. D., Wolpert, C., et al. (2004) · Circulation · doi:10.1161/01.cir.0000109482.92774.3a · Cited by 847
Pyle, W. G., & Solaro, R. J. (2004) · Circulation Research · doi:10.1161/01.res.0000116143.74830.a9 · Cited by 246
Falk, R. H., Pollak, A., Singh, S. N., & Friedrich, T. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00506-2 · Cited by 215
Metadata
- Authors
- Sanguinetti, M. C., & Jurkiewicz, N. K.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1990-07-01
- Volume
- 96
- Issue
- 1
- Pages
- 195-215
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W1975869151
- Cited by
- 1,457
- References
- 0
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two components of cardiac delayed rectifier K+ current. Differential sensitivity to block by class III antiarrhythmic agents. https://app.cochat.ai/papers/10.1085/jgp.96.1.195
- The paper
- Sanguinetti, M. C., & Jurkiewicz, N. K. (1990). Two components of cardiac delayed rectifier K+ current. Differential sensitivity to block by class III antiarrhythmic agents. The Journal of general physiology. https://doi.org/10.1085/jgp.96.1.195
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.