The DOI matches its Crossref record.
Spectral Irradiance Calibration in the Infrared. XIV. The Absolute Calibration of 2MASS
Open accessAbstract
Element by element, we have combined the optical components in the three cameras of the Two Micron All Sky Survey (2MASS), and incorporated detector quantum efficiency curves and site-specific atmospheric transmissions, to create three relative spectral response curves (RSRs). We provide the absolute 2MASS attributes associated with "zero magnitude" in the JHK s bands so that these RSRs may be used for synthetic photometry. The RSRs tie 2MASS to the "Cohen-Walker-Witteborn" framework of absolute photometry and stellar spectra for the purpose of using 2MASS data to support the development of absolute calibrators for the Infrared Array Camera and pairwise cross-calibrators between all three SIRTF instruments. We examine the robustness of these RSRs to changes in water vapor within a night. We compare the observed 2MASS magnitudes of 33 stars (converted from the precision optical calibrators of Landolt and Carter-Meadows into absolute infrared calibrators from 1.2 to 35 μm) with our predictions, thereby deriving 2MASS "zero-point offsets" from the ensemble. These offsets are the final ingredients essential to merge 2MASS JHK s data with our other absolutely calibrated bands and stellar spectra, and to support the creation of faint calibration stars for SIRTF .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Two Micron All Sky Survey (2MASS)
Skrutskie, M. F., Cutri, R. M., Stiening, R., Weinberg, M. D., Schneider, S., Carpenter, J. M., Beichman, C., Capps, R., Chester, T., Elias, J., et al. (2006) · The Astronomical Journal · doi:10.1086/498708 · Cited by 12,019
MESA ISOCHRONES AND STELLAR TRACKS (MIST). I. SOLAR-SCALED MODELS
Choi, J., Dotter, A., Conroy, C., Cantiello, M., Paxton, B., & Johnson, B. D. (2016) · The Astrophysical Journal · doi:10.3847/0004-637x/823/2/102 · Cited by 2,922
K -Corrections and Filter Transformations in the Ultraviolet, Optical, and Near-Infrared
Blanton, M. R., & Roweis, S. (2007) · The Astronomical Journal · doi:10.1086/510127 · Cited by 1,579
Marigo, P., Girardi, L., Bressan, A., Groenewegen, M. A. T., Silva, L., & Granato, G. L. (2008) · Astronomy & Astrophysics · doi:10.1051/0004-6361:20078467 · Cited by 1,553
Sousa, S. G., Santos, N. C., Mayor, M., Udry, S., Casagrande, L., Israelian, G., Pepe, F., Queloz, D., & Monteiro, M. J. P. F. G. (2008) · Astronomy & Astrophysics · doi:10.1051/0004-6361:200809698 · Cited by 650
Metadata
- Authors
- Cohen, M., Wheaton, W. A., & Megeath, S. T.
- Venue
- The Astronomical Journal
- Publisher
- American Astronomical Society
- Published
- 2003-08
- Volume
- 126
- Issue
- 2
- Pages
- 1090-1096
- ISSN
- 0004-6256 (ISSN-L)
- 1538-3881
- OpenAlex
- W2100820118
- Cited by
- 764
- References
- 0
- FWCI
- 36.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectral Irradiance Calibration in the Infrared. XIV. The Absolute Calibration of 2MASS. https://app.cochat.ai/papers/10.1086/376474
- The paper
- Cohen, M., Wheaton, W. A., & Megeath, S. T. (2003). Spectral Irradiance Calibration in the Infrared. XIV. The Absolute Calibration of 2MASS. The Astronomical Journal. https://doi.org/10.1086/376474
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.