Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 695

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Emergence of Community-Associated Methicillin-Resistant Staphylococcus aureus USA300 Genotype as a Major Cause of Health Care--Associated Blood Stream Infections

Seybold, U., Kourbatova, E. V., Johnson, J. G., Halvosa, S. J., Wang, Y. F., King, M. D., Ray, S. M., Blumberg, H. M.·2006·Clinical Infectious Diseases

Abstract

BACKGROUND: Whether community-associated methicillin-resistant Staphylococcus aureus (MRSA) genotypes (e.g., USA300) are a major cause of bloodstream infections (BSIs) and health care-associated infections has been poorly defined. METHODS: Consecutive MRSA isolates recovered from patients with BSIs were prospectively collected at an urban public hospital. Molecular typing studies were performed. Prevalence and risk factors for the MRSA USA300 genotype were assessed. RESULTS: One hundred thirty-two cases of MRSA BSI were documented over 7.5 months in 2004 (incidence, 6.79 per 1000 admissions); 116 isolates were available for genotyping. Characteristics of the 116 evaluable cases included: a mean age 47 years; 62% were male, 82% were African American, and 22% were HIV seropositive. The crude in-hospital mortality rate was 22%. In 107 cases (92%), there was contact with a health care facility within the year prior to infection, and a nosocomial infection (defined as positive blood culture results obtained >48 h after admission) occurred in 49 cases (42%). PFGE demonstrated that 39 (34%) of the 116 isolates were the MRSA USA300 genotype; 34 (29%) were USA100; 42 (36%) were USA500; and 1 (1%) was USA800. MRSA USA300 accounted for 28% of health care-associated BSIs and 20% of nosocomial MRSA BSIs. In multivariate analysis, isolation of the USA300 genotype was associated with injectiondrug use (OR, 3.67; 95% CI, 1.10-12.28) and skin and soft tissue infection (OR, 4.26; 95% CI, 1.08-16.84). Patients who resided in long-term care facilities (OR, 0.09; 95% CI, 0.01-0.82) and those who were treated with antimicrobials in the prior year were less likely to have MRSA USA300 genotype recovered (OR, 0.10; 95% CI, 0.02-0.49). CONCLUSIONS: MRSA USA300 genotype, the predominant cause of community-associated MRSA infections in our area (Atlanta, GA), has now emerged as a significant cause of health care-associated and nosocomial BSI. MRSA USA300 as a nosocomial pathogen presents new challenges to infection control programs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1086/499815

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 695

Metadata

Authors
Seybold, U., Kourbatova, E. V., Johnson, J. G., Halvosa, S. J., Wang, Y. F., King, M. D., Ray, S. M., & Blumberg, H. M.
Venue
Clinical Infectious Diseases
Published
2006-03-01
Volume
42
Issue
5
Pages
647-656
ISSN
  • 1058-4838 (ISSN-L)
  • 1537-6591
OpenAlex
W2144555634
Cited by
695
References
6
FWCI
44.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Emergence of Community-Associated Methicillin-Resistant Staphylococcus aureus USA300 Genotype as a Major Cause of Health Care--Associated Blood Stream Infections. https://app.cochat.ai/papers/10.1086/499815
The paper
Seybold, U., Kourbatova, E. V., Johnson, J. G., Halvosa, S. J., Wang, Y. F., King, M. D., Ray, S. M., & Blumberg, H. M. (2006). Emergence of Community-Associated Methicillin-Resistant Staphylococcus aureus USA300 Genotype as a Major Cause of Health Care--Associated Blood Stream Infections. Clinical Infectious Diseases. https://doi.org/10.1086/499815

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.