Legislative Mandates for Use of Active Surveillance Cultures to Screen for Methicillin-Resistant Staphylococcus aureus and Vancomycin-Resistant Enterococci: Position Statement From the Joint SHEA and APIC Task Force
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Legislation aimed at controlling antimicrobial-resistant pathogens through the use of active surveillance cultures to screen hospitalized patients has been introduced in at least 2 US states. In response to the proposed legislation, the Society for Healthcare Epidemiology of America (SHEA) and the Association of Professionals in Infection Control and Epidemiology (APIC) have developed this joint position statement. Both organizations are dedicated to combating healthcare-associated infections with a wide array of methods, including the use of active surveillance cultures in appropriate circumstances. This position statement reviews the proposed legislation and the rationale for use of active surveillance cultures, examines the scientific evidence supporting the use of this strategy, and discusses a number of unresolved issues surrounding legislation mandating use of active surveillance cultures. The following 5 consensus points are offered. (1) Although reducing the burden of antimicrobial-resistant pathogens, including methicillin-resistant Staphylococcus aureus(MRSA) and vancomycin-resistant enterococci (VRE), is of preeminent importance, APIC and SHEA do not support legislation to mandate use of active surveillance cultures to screen for MRSA, VRE, or other antimicrobial-resistant pathogens. (2) SHEA and APIC support the continued development, validation, and application of efficacious and cost-effective strategies for the prevention of infections caused by MRSA, VRE, and other antimicrobial-resistant and antimicrobial-susceptible pathogens. (3) APIC and SHEA welcome efforts by healthcare consumers, together with private, local, state, and federal policy makers, to focus attention on and formulate solutions for the growing problem of antimicrobial resistance and healthcare-associated infections. (4) SHEA and APIC support ongoing additional research to determine and optimize the appropriateness, utility, feasibility, and cost-effectiveness of using active surveillance cultures to screen both lower-risk and high-risk populations. (5) APIC and SHEA support stronger collaboration between state and local public health authorities and institutional infection prevention and control experts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effectiveness of a hospital-wide programme to improve compliance with hand hygiene
Pittet, D., Hugonnet, S., Harbarth, S., Mourouga, P., Sauvan, V., Touveneau, S., & Perneger, T. V. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02814-2 · Cited by 2,524
Methicillin-Resistant S. aureus Infections among Patients in the Emergency Department
Moran, G. J., Krishnadasan, A., Gorwitz, R. J., Fosheim, G. E., McDougal, L. K., Carey, R. B., & Talan, D. A. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa055356 · Cited by 2,285
King, M. D., Humphrey, B. J., Wang, Y. F., Kourbatova, E. V., Ray, S. M., & Blumberg, H. M. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-5-200603070-00005 · Cited by 776
DiazGranados, C. A., Zimmer, S. M., Mitchel, K., & Jernigan, J. A. (2005) · Clinical Infectious Diseases · doi:10.1086/430909 · Cited by 459
Cited by
Targeted versus universal decolonization to prevent ICU infection
Huang, S. S., Septimus, E., Kleinman, K., Moody, J., Hickok, J., Avery, T. R., Lankiewicz, J., Gombosev, A., Terpstra, L., Hartford, F., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1207290 · Cited by 795
Self-citationHospital Epidemiology and Infection Control in Acute-Care Settings
Sydnor, E. R. M., & Perl, T. M. (2011) · Clinical Microbiology Reviews · doi:10.1128/cmr.00027-10 · Cited by 652
Adverse outcomes associated with contact precautions: A review of the literature
Morgan, D. J., Diekema, D. J., Sepkowitz, K., & Perencevich, E. N. (2009) · American Journal of Infection Control · doi:10.1016/j.ajic.2008.04.257 · Cited by 329
Reduction of Methicillin-Resistant Staphylococcus aureus Infection among Veterans in Atlanta
Stenehjem, E., Stafford, C., & Rimland, D. (2013) · Infection Control & Hospital Epidemiology · doi:10.1086/668776 · Cited by 14
Metadata
- Authors
- Weber, S. G., Huang, S. S., Oriola, S., Huskins, W. C., Noskin, G. A., Harriman, K., Olmsted, R. N., Bonten, M., Lundstrom, T., Climo, M. W., Roghmann, M.-C., Murphy, C. L., & Karchmer, T. B.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 2007-03
- Volume
- 28
- Issue
- 3
- Pages
- 249-260
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2154909081
- Cited by
- 117
- References
- 4
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.