The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Emergence of Community-Acquired Methicillin-Resistant Staphylococcus aureus USA 300 Clone as the Predominant Cause of Skin and Soft-Tissue Infections
Abstract
BACKGROUND: Studies have shown that community-acquired methicillin-resistant Staphylococcus aureus (MRSA) causes S. aureus skin and soft-tissue infection in selected populations. OBJECTIVE: To determine the proportion of infections caused by community-acquired MRSA, the clinical characteristics associated with community-acquired MRSA, and the molecular epidemiology of community-acquired MRSA among persons with community-onset S. aureus skin and soft-tissue infection. DESIGN: Active, prospective laboratory surveillance to identify S. aureus recovered from skin and soft-tissue sources. SETTING: 1000-bed urban hospital and its affiliated outpatient clinics in Atlanta, Georgia. PATIENTS: 384 persons with microbiologically confirmed community-onset S. aureus skin and soft-tissue infection. MEASUREMENTS: Proportion of infections caused by and clinical factors associated with community-acquired MRSA among persons with community-onset S. aureus skin and soft-tissue infection. Pulsed-field gel electrophoresis and antimicrobial susceptibility patterns were used to epidemiologically classify community-onset S. aureus infections. Community-acquired MRSA was defined by MRSA isolates that either demonstrated a USA 300 or USA 400 pulsed-field type or had a susceptibility pattern showing resistance only to beta-lactams and erythromycin (for isolates not available for pulsed-field gel electrophoresis). RESULTS: Community-onset skin and soft-tissue infection due to S. aureus was identified in 389 episodes, with MRSA accounting for 72% (279 of 389 episodes). Among all S. aureus isolates, 63% (244 of 389 isolates) were community-acquired MRSA. Among MRSA isolates, 87% (244 of 279 isolates) were community-acquired MRSA. When analysis was restricted only to MRSA isolates that were available for pulsed-field gel electrophoresis, 91% (159 of 175 isolates) had a pulsed-field type consistent with community-acquired MRSA; of these, 99% (157 of 159 isolates) were the MRSA USA 300 clone. Factors independently associated with community-acquired MRSA infection were black race (prevalence ratio, 1.53 [95% CI, 1.16 to 2.02]), female sex (prevalence ratio, 1.16 [CI, 1.02 to 1.32]), and hospitalization within the previous 12 months (prevalence ratio, 0.80 [CI, 0.66 to 0.97]). Inadequate initial antibiotic therapy was statistically significantly more common among those with community-acquired MRSA (65%) than among those with methicillin-susceptible S. aureus skin and soft-tissue infection (1%). LIMITATIONS: Some MRSA isolates were not available for molecular typing. CONCLUSIONS: The community-acquired MRSA USA 300 clone was the predominant cause of community-onset S. aureus skin and soft-tissue infection. Empirical use of agents active against community-acquired MRSA is warranted for patients presenting with serious skin and soft-tissue infections.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The leading cause of community-associated bacterial infections in the United States is the MRSA isolate USA300 [25]”
From Interactions of Methicillin Resistant Staphylococcus aureus USA300 and Pseudomonas aeruginosa in Polymicrobial Wound Infection (2013) · cites this paper as [25]
Citations
Cites
Methods for dilution antimicrobial susceptibility tests for bacteria that grow aerobically
Ferraro, M. J. (2000) · Cited by 16,875
Tenover, F. C., Arbeit, R. D., Goering, R. V., Mickelsen, P. A., Murray, B. E., Persing, D. H., & Swaminathan, B. (1995) · Journal of Clinical Microbiology · doi:10.1128/jcm.33.9.2233-2239.1995 · Cited by 8,203
Lina, G., Piemont, Y., Godail-Gamot, F., Bes, M., Peter, M.-O., Gauduchon, V., Vandenesch, F., & Etienne, J. (1999) · Clinical Infectious Diseases · doi:10.1086/313461 · Cited by 2,489
Naimi, T. S. (2003) · JAMA · doi:10.1001/jama.290.22.2976 · Cited by 1,688
McDougal, L. K., Steward, C. D., Killgore, G., Chaitram, J. M., McAllister, S. K., & Tenover, F. C. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.11.5113-5120.2003 · Cited by 1,410
Dissemination of New Methicillin-Resistant Staphylococcus aureus Clones in the Community
Okuma, K., Iwakawa, K., Turnidge, J. D., Grubb, W. B., Bell, J. M., O’Brien, F. G., Coombs, G. W., Pearman, J. W., Tenover, F. C., Kapi, M., et al. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.11.4289-4294.2002 · Cited by 888
(1995) · American Journal of Infection Control · doi:10.1016/0196-6553(95)90104-3 · Cited by 708
Seybold, U., Kourbatova, E. V., Johnson, J. G., Halvosa, S. J., Wang, Y. F., King, M. D., Ray, S. M., & Blumberg, H. M. (2006) · Clinical Infectious Diseases · doi:10.1086/499815 · Cited by 687
Self-citationPulsed-field gel electrophoresis as a replacement for bacteriophage typing of Staphylococcus aureus
Bannerman, T. L., Hancock, G. A., Tenover, F. C., & Miller, J. M. (1995) · Journal of Clinical Microbiology · doi:10.1128/jcm.33.3.551-555.1995 · Cited by 550
Lee, M., RIOS, A. M., Fonseca-Aten, M., Mejías, A., Cavuoti, D., McCracken, G. H., & Hardy, R. D. (2004) · The Pediatric Infectious Disease Journal · doi:10.1097/01.inf.0000109288.06912.21 · Cited by 392
Flagged first, then by citations
Research works printed but not linked: 4
- 2003, MMWR Morb Mortal Wkly Rep, 52, 992
- 2003, MMWR Morb Mortal Wkly Rep, 52, 793
- 2003, MMWR Morb Mortal Wkly Rep, 52, 88
- 1995, MMWR Recomm Rep, 44, 1
Cited by
Sorted by citations
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
David, M. Z., & Daum, R. S. (2010) · Clinical Microbiology Reviews · doi:10.1128/cmr.00081-09 · Cited by 1,972
Health Care–Associated Invasive MRSA Infections, 2005-2008
Kallen, A. J. (2010) · JAMA · doi:10.1001/jama.2010.1115 · Cited by 439
Antibiotic-loaded nanoparticles targeted to the site of infection enhance antibacterial efficacy
Hussain, S., Joo, J., Kang, J., Kim, B., Braun, G. B., She, Z.-G., Kim, D., Mann, A. P., Mölder, T., Teesalu, T., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0187-5 · Cited by 399
Pastar, I., Nusbaum, A. G., Gil, J., Patel, S. B., Chen, J., Valdes, J., Stojadinovic, O., Plano, L. R., Tomic-Canic, M., & Davis, S. C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056846 · Cited by 391
Metadata
- Authors
- King, M. D., Humphrey, B. J., Wang, Y. F., Kourbatova, E. V., Ray, S. M., & Blumberg, H. M.
- Affiliations
- Grady Memorial Hospital (US)
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2006-03-07
- Volume
- 144
- Issue
- 5
- Pages
- 309-317
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2101357306
- Cited by
- 776
- References
- 26
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 5 · 2023: 17 · 2022: 14 · 2021: 15 · 2020: 9 · 2019: 20 · 2018: 20 · 2017: 24 · 2016: 32 · 2015: 38 · 2014: 38 · 2013: 46 · 2012: 54
- FWCI
- 58.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Allergy and Infectious Diseases (K23AI054371)
- National Center for Research Resources (K12RR017643)
- Topics
- Health Sciences › Medicine › Infectious Diseases › Antimicrobial Resistance in Staphylococcus
- Health Sciences › Medicine › Infectious Diseases › Antibiotic Use and Resistance
- Health Sciences › Medicine › Infectious Diseases › Dermatological diseases and infestations
- Keywords
- community-acquired MRSA, methicillin-resistant Staphylococcus aureus, skin and soft tissue infections, molecular epidemiology, pulsed-field gel electrophoresis, antimicrobial susceptibility, beta-lactam resistance, erythromycin resistance, risk factors, race, hospital surveillance, Atlanta, community-onset infection, nosocomial infections
- MeSH terms
- Black or African American, Female, Georgia, Hospitalization, Humans, Male, Risk Factors, Sex Factors, Staphylococcal Infections, Staphylococcal Skin Infections, Staphylococcus aureus, Methicillin Resistance, Electrophoresis, Gel, Pulsed-Field, Community-Acquired Infections, Soft Tissue Infections, Black People
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review