The DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index.
Room Decontamination with UV Radiation
Abstract
OBJECTIVE: To determine the effectiveness of a UV-C-emitting device to eliminate clinically important nosocomial pathogens in a contaminated hospital room. METHODS: This study was carried out in a standard but empty hospital room (phase 1) and in a room previously occupied by a patient with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus (VRE) infection (phase 2) in an acute care tertiary hospital in North Carolina from January 21 through September 21, 2009. During phase 1, 8 x 8 cm Formica sheets contaminated with approximately 10(4)-10(5) organisms of MRSA, VRE, multidrug-resistant (MDR) Acinetobacter baumannii, or Clostridium difficile spores were placed in a hospital room, both in direct line of sight of the UV-C device and behind objects. After timed exposure, the presence of the microbes was assessed. During phase 2, specific sites in rooms that had housed patients with MRSA or VRE infection were sampled before and after UV-C irradiation. After timed exposure, the presence of MRSA and VRE and total colony counts were assessed. RESULTS: In our test room, the effectiveness of UV-C radiation in reducing the counts of vegetative bacteria on surfaces was more than 99.9% within 15 minutes, and the reduction in C. difficile spores was 99.8% within 50 minutes. In rooms occupied by patients with MRSA, UV-C irradiation of approximately 15 minutes duration resulted in a decrease in total CFUs per plate (mean, 384 CFUs vs 19 CFUs; P < .001), in the number of samples positive for MRSA (81 [20.3%] of 400 plates vs 2 [0.5%] of 400 plates; P < .001), and in MRSA counts per MRSA-positive plate (mean, 37 CFUs vs 2 CFUs; P < .001). CONCLUSIONS: This UV-C device was effective in eliminating vegetative bacteria on contaminated surfaces both in the line of sight and behind objects within approximately 15 minutes and in eliminating C. difficile spores within 50 minutes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In studies investigating the efficacy, UV has been shown to have a high capacity to kill microbes found on humans with elevated times of exposure needed to inactivate particularly resilient organisms, such as anthrax spores, C. difficile and P. aeruginosa biofilms [119,120,121].”
Citations
Cites
Official Methods of Analysis of AOAC International
Horwitz, W., & LATIMER, G. W. (2006) · Medical Entomology and Zoology · Cited by 10,948
Official Methods of Analysis of AOAC INTERNATIONAL
(2023) · Oxford University Press eBooks · doi:10.1093/9780197610145.001.0001 · Cited by 5,942
Risk of Acquiring Antibiotic-Resistant Bacteria From Prior Room Occupants
Huang, S. S. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.18.1945 · Cited by 516
Disinfection, Sterilization and Preservation
Plein, E. M. (1977) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/34.12.1372 · Cited by 427
Drees, M. L., Snydman, D. R., Schmid, C. H., Barefoot, L., Hansjosten, K., Vue, P. M., Cronin, M., Nasraway, S. A., & Golan, Y. (2008) · Clinical Infectious Diseases · doi:10.1086/527394 · Cited by 305
Improving Cleaning of the Environment Surrounding Patients in 36 Acute Care Hospitals
Carling, P., Parry, M. M., Rupp, M. E., Po, J. L., Dick, B., Beheren, S. V., & Healthcare Environmental Hygiene Study Group (2008) · Infection Control and Hospital Epidemiology · doi:10.1086/591940 · Cited by 264
Identifying Opportunities to Enhance Environmental Cleaning in 23 Acute Care Hospitals
Carling, P., Parry, M. F., Beheren, S. V., & Healthcare Environmental Hygiene Study Group (2007) · Infection Control and Hospital Epidemiology · doi:10.1086/524329 · Cited by 253
Improved Cleaning of Patient Rooms Using a New Targeting Method
Carling, P., Briggs, J. L., Perkins, J., & Highlander, D. (2006) · Clinical Infectious Diseases · doi:10.1086/499361 · Cited by 167
Rastogi, V. K., Wallace, L., & Smith, L. S. (2007) · Military Medicine · doi:10.7205/milmed.172.11.1166 · Cited by 47
New Approaches to Decontamination of Rooms After Patients Are Discharged
Boyce, J. M. (2009) · Infection Control and Hospital Epidemiology · doi:10.1086/598999 · Cited by 46
Research works printed but not linked: 3
- Rutala, 2009, APIC Text of Infection Control and Epidemiology, 21, 1
- Blatchley, 2001, Disinfection, Sterilization and Preservation, 823
- Shaughnessy, 2008, Programs and abstracts of the 48th Annual Interscience Conference on Antimicrobial Agents and Chemotherapy/Infections Disease Society of America 46th Annual Meeting
Cited by
Sorted by citations
Items 101–200 of 224
Ultraviolet-C light as a means of disinfecting anesthesia workstations
Nottingham, M., Peterson, G. N., Doern, C. D., Doll, M. E., Masroor, N., Sanogo, K., Stevens, M., & Bearman, G. M. (2017) · American Journal of Infection Control · doi:10.1016/j.ajic.2017.02.016 · Cited by 21
Muzslay, M., Yui, S., Ali, S., & Wilson, A. P. R. (2018) · Journal of Hospital Infection · doi:10.1016/j.jhin.2018.04.002 · Cited by 21
Gostine, A., Gostine, D., Donohue, C., & Carlstrom, L. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.012 · Cited by 20
Reduced isolation room turnover time using Lean methodology
Ankrum, A. L., Neogi, S., Morckel, M. A., Wilhite, A. W., Li, Z., & Schaffzin, J. K. (2019) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2019.199 · Cited by 20
Role of the hospital environment in disease transmission, with a focus on Clostridium difficile
Rutala, W. A., & Weber, D. J. (2013) · Healthcare Infection · doi:10.1071/hi12057 · Cited by 20
Self-citationAalirezaie, A., Akkaya, M., Barnes, C. L., Bengoa, F. J., Bozkurt, M., Cichos, K. H., Ghanem, E. S., Darouiche, R. O., Džeriņš, A., Gürsoy, S., et al. (2018) · The Journal of Arthroplasty · doi:10.1016/j.arth.2018.09.060 · Cited by 20
The Role of the Environment and Colonization in Healthcare-Associated Infections
Wohrley, J. D., & Bartlett, A. H. (2018) · Springer eBooks · doi:10.1007/978-3-319-98122-2_2 · Cited by 20
Sheikh, J., Swee, T. T., Saidin, S., Malik, S. A., Chua, L. S., Thye, M. T. F., Meng, L. K., & Kun, M. (2024) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-024-05635-3 · Cited by 19
Contamination of the Hospital Environmental by Pathogenic Bacteria and Infection Control
Kim, Y. A., Lee, H., & Lee, K. (2015) · Korean Journal of Nosocomial Infection Control · doi:10.14192/kjnic.2015.20.1.1 · Cited by 19
Recent Progress on Aluminum Gallium Nitride Deep Ultraviolet Lasers by Molecular Beam Epitaxy
Zhang, Q., Yin, X., & Zhao, S. (2021) · physica status solidi (RRL) - Rapid Research Letters · doi:10.1002/pssr.202100090 · Cited by 19
Automated room decontamination: report of a Healthcare Infection Society Working Party
Beswick, A. J., Fry, C., Bradley, C. R., Pottage, T., Sharpe, S. A., Haill, C., Mugglestone, M. A., Bak, A., Marsden, G. L., Bennett, A., et al. (2022) · Journal of Hospital Infection · doi:10.1016/j.jhin.2022.01.006 · Cited by 19
Innovative Methods of Hospital Disinfection in Prevention of Healthcare-Associated Infections
Rock, C., Small, B. A., & Thom, K. A. (2018) · Current treatment options in infectious diseases/Current treatment options in infectious disease · doi:10.1007/s40506-018-0153-0 · Cited by 18
Armellino, D., Walsh, T. J., Petraitis, V., & Kowalski, W. J. (2018) · American Journal of Infection Control · doi:10.1016/j.ajic.2018.09.019 · Cited by 18
Chen, L., Chang, J., Chu, H.-T., Chen, Y., Jiang, H., Wang, L.-S., Teh, S.-H., Yang, H., Chen, D.-S., Li, Y., et al. (2022) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2022.113476 · Cited by 17
Chen, L. F., Chastain, C. A., & Anderson, D. J. (2011) · Current Infectious Disease Reports · doi:10.1007/s11908-011-0198-4 · Cited by 17
Viegas, C. S. B., Twarużek, M., Lourenço, R. M. V. L., Dias, M., Almeida, B., Caetano, L. A., Carolino, E., Gomes, A. Q., Kosicki, R., Soszczyńska, E., et al. (2020) · Atmosphere · doi:10.3390/atmos11040351 · Cited by 17
Ultraviolet-C decontamination of a dental clinic setting: required amount of UV light
Botta, S. B., Teixeira, F. S., Hanashiro, F. S., Araújo, W. W. R., Cassoni, A., & Salvadori, M. C. (2020) · Brazilian Dental Science · doi:10.14295/bds.2020.v23i2.2275 · Cited by 17
Rock, C., Curless, M. S., Nowakowski, E., Ross, T. L., Carson, K. A., Trexler, P. A., Carroll, K. C., & Maragakis, L. L. (2016) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2016.111 · Cited by 17
Basak, S. S., & Adak, A. K. (2024) · Journal of Environmental Health Science and Engineering · doi:10.1007/s40201-024-00893-2 · Cited by 16
The uses and limitations of a hand-held germicidal ultraviolet wand for surface disinfection
Byrns, G. E., Barham, B. J., Yang, L., Webster, K., Rutherford, G. H., Steiner, G., Petras, D., & Scannell, M. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2017.1328106 · Cited by 16
Penno, K., Jandarov, R., & Sopirala, M. M. (2017) · American Journal of Infection Control · doi:10.1016/j.ajic.2017.06.015 · Cited by 16
A guide to no-touch automated room disinfection (NTD) systems
Otter, J. A., Yezli, S., Perl, T. M., Barbut, F., & French, G. L. (2014) · Elsevier eBooks · doi:10.1533/9780857096692.2.413 · Cited by 16
Disinfection of Airborne Organisms by Ultraviolet‐C Radiation and Sunlight
Kesavan, J. S., & Sagripanti, J. (2013) · Wiley eBooks · doi:10.1002/9781118682555.ch17 · Cited by 16
Observations on hospital room contamination testing
Smith, P. W., Gibbs, S. G., Sayles, H. R., Hewlett, A. L., Rupp, M. E., & Iwen, P. C. (2013) · Healthcare Infection · doi:10.1071/hi12049 · Cited by 15
Rudhart, S. A., Günther, F. A., Dapper, L., Thangavelu, K., Gehrt, F., Stanković, P., Wilhelm, T., Guenzel, T., Stuck, B. A., & Hoch, S. (2020) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-020-05978-w · Cited by 15
Endo, T., Gemma, A., Mitsuyoshi, R., Kodama, H., Asaka, D., Kono, M., Mochizuki, T., Kojima, H., Iwamoto, T., & Saitô, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-01315-1 · Cited by 15
Spencer, M., Vignari, M., Bryce, E., Johnson, H. B., Fauerbach, L., & Graham, D. H. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.11.016 · Cited by 15
Pfendler, S., Munch, T., Bousta, F., Alaoui-Sossé, L., Aleya, L., & Alaoui-Sossé, B. (2018) · Environmental Science and Pollution Research · doi:10.1007/s11356-018-1654-6 · Cited by 15
Blau, K., & Gallert, C. (2024) · Pathogens · doi:10.3390/pathogens13110965 · Cited by 14
AlBahrani, S., Saad, M. M., Alqahtani, J. S., Almoosa, Z., Alabdulla, M., Algezery, M., AlShehri, S., & Al‐Tawfiq, J. A. (2024) · Journal of Epidemiology and Global Health · doi:10.1007/s44197-024-00297-3 · Cited by 13
Resendiz, M., Blanchard, D. M., & West, G. F. (2023) · Journal of Infection Prevention · doi:10.1177/17571774231159388 · Cited by 13
Commission For Hospital Hygiene And Infection Prevention (KRINKO) (2024) · PubMed Central · doi:10.3205/dgkh000468 · Cited by 13
Evaluation of an automated room decontamination device using aerosolized peracetic acid
Mana, T. S. C., Sitzlar, B. M., Cadnum, J. L., Jencson, A. L., Koganti, S., & Donskey, C. J. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.10.006 · Cited by 13
Effectiveness Evaluation of a UV-C-Photoinactivator against Selected ESKAPE-E Pathogens
Rangel, K., Cabral, F. O., Lechuga, G. C., H, S. V.-B. M., Midlej, V. D. V. P., & De-Simone, S. G. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192416559 · Cited by 13
Arkusz, K., Pasik, K., Jędrzejewska, A., Klekiel, T., Woźniak, W., Nycz, M., & Stryjski, R. (2024) · PLoS ONE · doi:10.1371/journal.pone.0302258 · Cited by 13
Decontamination of the Hospital Environment: New Technologies for Infection Control
Maclean, M., McKenzie, K., Moorhead, S., Tomb, R., Coia, J. E., MacGregor, S. J., & Anderson, J. G. (2015) · Current treatment options in infectious diseases/Current treatment options in infectious disease · doi:10.1007/s40506-015-0037-5 · Cited by 12
Knobling, B., Ulatowski, A., Franke, G. C., Campos, C. E. B., Büttner, H., Klupp, E. M., Maurer, P. M., Brill, F. H. H., & Knobloch, J. K. ‐. (2023) · Journal of Hospital Infection · doi:10.1016/j.jhin.2023.07.017 · Cited by 11
Martinello, R. A., Poster, D. L., Miller, C. C., Obeng, Y. S., Postek, M. T., & Cowan, T. E. (2018) · Nanoengineering: Fabrication, Properties, Optics, Thin Films, and Devices · doi:10.1117/12.2500431 · Cited by 11
Choi, H., Chatterjee, P., Hwang, M., Stock, E. M., Lukey, J., Zeber, J. E., & Jinadatha, C. (2021) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2021.51 · Cited by 11
Rutala, W. A., Weber, D. J., Gergen, M. F., Tande, B. M., & Sickbert-Bennett, E. E. (2014) · Infection Control and Hospital Epidemiology · doi:10.1086/675291 · Cited by 11
Self-citationHospital Infection Prevention and Control Issues Relevant to Extensive Floods
Apisarnthanarak, A., Mundy, L. M., Khawcharoenporn, T., & Mayhall, C. G. (2012) · Infection Control and Hospital Epidemiology · doi:10.1086/669094 · Cited by 11
Prevention of Infection due to Clostridium (Clostridioides) difficile
Krishna, A., & Chopra, T. (2021) · Infectious Disease Clinics of North America · doi:10.1016/j.idc.2021.07.009 · Cited by 10
Path and Trajectory Planning for UV-C Disinfection Robots
Dogru, S., & Marques, L. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3280800 · Cited by 10
Impact of an ultraviolet air sterilizer on cardiac surgery patients, a randomized clinical trial
Heredia‐Rodríguez, M., Álvarez-Fuente, E., Bustamante‐Munguira, J., Poves‐Álvarez, R., Fierro, I., Gómez‐Sánchez, E., Gómez‐Pesquera, E., Lorenzo‐López, M., Bouza, J. M. E., Álvarez, F. J., et al. (2018) · Medicina Clínica · doi:10.1016/j.medcli.2018.04.015 · Cited by 9
Kwait, R. E., Kerwin, K., Herzog, C., Bennett, J. W., Padhi, S., Zoccolo, I., & Maslo, B. (2022) · Conservation Science and Practice · doi:10.1111/csp2.623 · Cited by 8
Halmans, Y., Wellenstein, D. J., Romijn, M., van Bemmel, A. J. M., Berge, H., Scheeren, R. A., Kalpoe, J., Klont, R., van Zeijl, J. H., Sikkema, H., et al. (2024) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-024-01486-2 · Cited by 9
Endarko, E., Putro, T., Nuzula, N. I., Armawati, N., Wardana, A., Rubiyanto, A., & Muntini, M. S. (2013) · BERKALA FISIKA · Cited by 7
Sommers, C. H., Scullen, O. J., & Paoli, G. C. (2012) · Journal of Food Processing & Technology · doi:10.4172/2157-7110.s11-002 · Cited by 7
Kunishima, H., Ichiki, K., Ohge, H., Sakamoto, F., Sato, Y., Suzuki, H., Nakamura, A., Fujimura, S., Matsumoto, K., Mikamo, H., et al. (2024) · Journal of Infection and Chemotherapy · doi:10.1016/j.jiac.2024.03.018 · Cited by 6
Aeronautics in dentistry: Navigating oral health challenges in zero gravity
Doshi, D. J., & Tamgadge, S. (2024) · Journal of Academy of Dental Education · doi:10.25259/jade_36_2024 · Cited by 6
Bacterial Morphology and Microscopic Advancements: Navigating from Basics to Breakthroughs
Sheikh, J., Swee, T. T., Malik, S. A., Saidin, S., & Chua, L. S. (2024) · Microbiological & Immunological Communications · doi:10.55627/mic.003.001.0567 · Cited by 6
Zakaria, F., Harelimana, B., Ćurko, J., van de Vossenberg, J. L. C. M., García, H. A., Hooijmans, C. M., & Brdjanović, D. (2016) · International Journal of Environmental Health Research · doi:10.1080/09603123.2016.1217313 · Cited by 6
Sathitakorn, O., Jantarathaneewat, K., Weber, D. J., Apisarnthanarak, P., Rutjanawech, S., & Apisarnthanarak, A. (2023) · Antibiotics · doi:10.3390/antibiotics12030438 · Cited by 6
Self-citationAn airlock concept to reduce contamination risks during the human exploration of Mars
Vrankar, D., Verseux, C., & Heinicke, C. (2023) · npj Microgravity · doi:10.1038/s41526-023-00329-5 · Cited by 6
Inactivation of avirulent pgm+ and Δpgm Yersinia pestis by ultraviolet light (UV-C)
Paoli, G. C., Sommers, C. H., Scullen, O. J., & Wijey, C. (2014) · Food Microbiology · doi:10.1016/j.fm.2014.06.002 · Cited by 5
Advances in Infection Control for Clostridioides (Formerly Clostridium) difficile Infection
Castro, C. E. F., & Munoz-Price, L. S. (2019) · Current treatment options in infectious diseases/Current treatment options in infectious disease · doi:10.1007/s40506-019-0179-y · Cited by 5
Barakat, M. T., Banerjee, S., Lee, L. D., & Angelotti, T. P. (2023) · American Journal of Infection Control · doi:10.1016/j.ajic.2023.09.016 · Cited by 4
Evaluating the Utility of UV Lamps to Mitigate the Spread of Pathogens in the ICU
Gostine, A., Gostine, D., Short, J. H., Rustagi, A., Cadnum, J. L., Donskey, C. J., & Angelotti, T. (2020) · Applied Sciences · doi:10.3390/app10186326 · Cited by 4
Analysis of impact of nosocomial infections on cost of patient hospitalisation
Blatnik, P., & Bojnec, Š. (2023) · Central European Journal of Public Health · doi:10.21101/cejph.a7631 · Cited by 5
Ezeh, U. C., Achlatis, E., Crosby, T. W., Kwak, P. E., Phillips, M., & Amin, M. R. (2023) · The Laryngoscope · doi:10.1002/lary.30869 · Cited by 4
Rodgers, M. P., Cremers, S., & Bowles, E. C. (2023) · Infection Prevention in Practice · doi:10.1016/j.infpip.2023.100322 · Cited by 4
Sedaghat, Y., Gholampour, S., & Ghomshe, F. T. (2020) · Infektološki glasnik · doi:10.37797/ig.39.3.2 · Cited by 4
Carling, P. (2017) · Springer eBooks · doi:10.1007/978-3-319-60980-5_8 · Cited by 4
Daud, N. S. S., Dunn, M., Moncayo-Nieto, O. L., & Hay, A. W. (2023) · Infection Prevention in Practice · doi:10.1016/j.infpip.2023.100307 · Cited by 3
Is UV-C light disinfection suitable as a disinfection method for medical devices: a scoping review
Halmans, Y., Wellenstein, D. J., Hopman, J., Takes, R. P., & van den Broek, G. (2025) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-025-01669-5 · Cited by 3
Smith, M. (2022) · Nursing · doi:10.1097/01.nurse.0000829900.60122.4c · Cited by 3
Spaceflight hygiene: A keynote for space travelers and spacecraft designers
Oluwafemi, F. A., & Olubiyi, R. A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22259-7.00020-5 · Cited by 3
Wiśniewski, A., Skarżyński, K., Pracki, P., Krupiński, R., Wolska, A., Wisełka, M., & Pawlak, A. (2024) · LEUKOS The Journal of the Illuminating Engineering Society of North America · doi:10.1080/15502724.2024.2392569 · Cited by 3
Rapid Inactivation of E. coli by Water Droplet-Tuned Surface Micro-Discharges
Wang, X., Qi, Z., Zhao, Z., Xia, Y., Li, H., Chu, H., Wang, Z., Mu, Z., & Liu, D. (2022) · Plasma Chemistry and Plasma Processing · doi:10.1007/s11090-022-10275-x · Cited by 3
Lysova, N., Solari, F., Bocelli, M., Volpi, A., & Montanari, R. (2024) · International Journal of Food Engineering · doi:10.1515/ijfe-2023-0065 · Cited by 3
Rapid design and implementation of a UVC decontamination room
Hummel, A., Ergai, A., Spiva, L., Toney, S., & Crawford, A. (2022) · Scientific Reports · doi:10.1038/s41598-022-04926-4 · Cited by 3
Safe surgical practices and asepsis
Shenoy, R. M., & Shenoy, A. (2013) · Archives of Medicine and Health Sciences · doi:10.4103/2321-4848.113562 · Cited by 3
Control ofClostridium difficileinfection in the hospital setting
Wiuff, C., Murdoch, H., & Coia, J. E. (2014) · Expert Review of Anti-infective Therapy · doi:10.1586/14787210.2014.894459 · Cited by 3
Revisiting Environmental Hygiene and Hospital-Acquired Infections
Currie, B. P. (2013) · Cited by 3
Activities of aClostridium difficileinfection reduction team
Eiland, E. H. (2011) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp100664 · Cited by 3
New Technologies for Infection Prevention
Doll, M. E., Stevens, M., & Bearman, G. M. (2017) · Springer eBooks · doi:10.1007/978-3-319-60980-5_7 · Cited by 3
Disinfection and Sterilization
Arduino, M. J., & McDonnell, G. E. (2023) · ClinMicroNow · doi:10.1002/9781683670438.mcm0015 · Cited by 3
The use of UV-C radiation for terminal disinfection of pathogenic Gram-negative rods: a pilot study
Tholany, J., Suzuki, H., Frank, A. R., Bryant, S. H., Goedken, C. C., Suh, D. Y., Stevens, M. S., Sherlock, S. H., & Perencevich, E. N. (2023) · Antimicrobial Stewardship & Healthcare Epidemiology · doi:10.1017/ash.2023.514 · Cited by 2
Yoshioka, J., Morikane, K., Nishimoto, C., Kimura, H., & Kawamae, K. (2021) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/jjmi.91.439 · Cited by 2
Squamous-cell carcinoma in situ
Rothman, L. R., Mir, A., Meehan, S. A., & Mitchell, W. L. (2015) · Dermatology Online Journal · doi:10.5070/d32112029530 · Cited by 2
Impact of an ultraviolet air sterilizer on cardiac surgery patients, a randomized clinical trial
Heredia‐Rodríguez, M., Álvarez-Fuente, E., Bustamante‐Munguira, J., Poves‐Álvarez, R., Fierro, I., Gómez‐Sánchez, E., Gómez‐Pesquera, E., Lorenzo‐López, M., Bouza, J. M. E., Álvarez, F. J., et al. (2018) · Medicina Clínica (English Edition) · doi:10.1016/j.medcle.2018.04.001 · Cited by 2
Facing the rising tide of multidrug resistant Gram-negative pathogens
Chen, L. F., Falagas, M. E., & Peleg, A. Y. (2011) · Healthcare Infection · doi:10.1071/hi11013 · Cited by 2
Evaluation of the disinfecting capacity of ozone in emergency vehiclesPreprint
Cía, J. B., Martínez, B. G., Montero, A. P., Kochan, G. T., Escors, D., Martínez, J. C., Uzcudun, I. L., & Sucunza, A. E. (2020) · medRxiv · doi:10.1101/2020.05.24.20111666 · Cited by 2
Pietrzak, J. R. T., Geldenhuys, D. B., Sekeitto, A. R., Sikhauli, N., & Mokete, L. (2026) · Orthopedic Reviews · doi:10.52965/001c.158942 · Cited by 1
Cobb, T. C. (2017) · Reviews in Medical Microbiology · doi:10.1097/mrm.0000000000000097 · Cited by 1
Environmental cleaning in the Emergency Department
Vang, J. (2014) · Cited by 1
Miller, C. C., Larason, T. C., Poster, D. L., Obeng, Y. S., Postek, M. T., Cowen, T. E., & Martinello, R. A. (2019) · Quadrennial Session of the International Commission on Illumination (CIE Session) · doi:10.25039/x46.2019.op23 · Cited by 1
小板功, 山岸, 由., 毛利, 哲., 村松, 有., 小泉, 祐., 塩田, 有., 末松寛之, & 三鴨, 廣. (2020) · 日本外科感染症学会雑誌 · doi:10.24679/gekakansen.17.3_104 · Cited by 1
Carling, P. (2022) · Springer eBooks · doi:10.1007/978-3-030-98427-4_8 · Cited by 1
Using Ultraviolet Light Technology to Enhance Cleaning in Health Care Settings
Sunshine, W. L. (2020) · AORN Journal · doi:10.1002/aorn.13017 · Cited by 1
Környezethigiéné: innovatív dekontaminációs technológiák
Szabó, R., Málics, L. S., & Barcs, I. (2020) · Egeszsegtudomany · doi:10.29179/egtud.2020.3.28-50 · Cited by 1
Byrns, G. E., Barham, B. J., Yang, L., Webster, K., Rutherford, G. H., Steiner, G., Petras, D., & Scannell, M. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1877057 · Cited by 1
Noroviruses on surfaces : Detection, transfer and inactivation
Rönnqvist, M. (2014) · Työväentutkimus Vuosikirja · Cited by 1
Evaluation of the Bactericidal Activity of Natural Nano Topography to Control Surface Contamination
Mudiyanselage, C. C. D. B. I. (2017) · Queensland University of Technology · doi:10.5204/thesis.eprints.106746 · Cited by 1
Nishiaki, A., Osawa, K., Nomoto, R., Yamane, K., Okumura, Y., Fujina, K., Ohashi, H., Koi, T., Hirai, A., & Shirakawa, T. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4861097 · Cited by 1
Disinfection and Sterilization
Arduino, M. J., & McDonnell, G. E. (2023) · ClinMicroNow · doi:10.1002/9781683674849.mcm0015 · Cited by 1
Quoi de neuf dans les techniques de désinfection des chambres de réanimation ?
Blazejewski, C., Wallet, F., & Nseir, S. (2014) · Réanimation · doi:10.1007/s13546-014-0884-y
Effectiveness of a Portable, Large-Area Ultraviolet Germicidal Device
Buttner, M. P., Yee, T. W., Cruz, P., & Stevens, V. (2012) · Digital Scholarship - UNLV (University of Nevada Reno)
Environmental Hygiene and Hospital-Acquired Infections
Currie, B. P. (2013)
Kyle, E. (2020) · AORN Journal · doi:10.1002/aorn.13036
Metadata
- Authors
- Rutala, W. A., Gergen, M. F., & Weber, D. J.
- Affiliations
- University of North Carolina at Chapel Hill (US)
- Corresponding author
- Rutala, William A.
- ORCID
- Weber, David J.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 2010-10
- Volume
- 31
- Issue
- 10
- Pages
- 1025-1029
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2143825991
- Cited by
- 221
- References
- 14
- Citations by year
- 2026: 9 · 2025: 4 · 2024: 17 · 2023: 21 · 2022: 14 · 2021: 13 · 2020: 15 · 2019: 15 · 2018: 13 · 2017: 14 · 2016: 16 · 2015: 14 · 2014: 17 · 2013: 19 · 2012: 10
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Infection Control and Hospital Epidemiology (publishedVersion)
- PubMed (publishedVersion)
- Infection Control and Hospital Epidemiology
- Funders
- U.S. Public Health Service (1ULRR025747-01)
- Topics
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Keywords
- UV-C disinfection, nosocomial pathogens, methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, Acinetobacter baumannii, multidrug-resistant bacteria, surface decontamination, hospital room disinfection
- MeSH terms
- Bacteria, Bacterial Infections, Cross Infection, Decontamination, Hospitals, Humans, North Carolina, Patients' Rooms, Ultraviolet Rays, Colony Count, Microbial, Clostridioides difficile, Enterococcus, Methicillin-Resistant Staphylococcus aureus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review