Multi-planar image formation using NMR spin echoes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A new method of two- or three-dimensional spin density imaging by nuclear magnetic resonance (NMR) is proposed, which exploits the properties of spin echoes in time-dependent magnetic field gradients. An analysis shows that simultaneous observation and differentiation of signals, arising from all spins distributed in a plane or set of planes within the specimen, is possible. The method is thus capable of producing visual pictures faster than previously described planar imaging methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kumar, A., Welti, D., & Ernst, R. R. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90224-3 · Cited by 311
Image formation in NMR by a selective irradiative process
Garroway, A. N., Grannell, P. K., & Mansfield, P. (1974) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/7/24/006 · Cited by 271
Self-citation"Diffraction" and microscopy in solids and liquids by NMR
Mansfield, P., & Grannell, P. K. (1975) · Physical Review B · doi:10.1103/physrevb.12.3618 · Cited by 266
Self-citation
Cited by
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551
Whalen, P. J., Rauch, S. L., Etcoff, N. L., McInerney, S. C., Lee, M. B., & Jenike, M. A. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-01-00411.1998 · Cited by 2,205
“Our Instascan software is a variant of the echo planar technique first described by Mansfield (1977).”
MethodSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Metadata
- Authors
- Mansfield, P.
- Venue
- Journal of Physics C: Solid State Physics
- Publisher
- IOP Publishing
- Published
- 1977-02-14
- Volume
- 10
- Issue
- 3
- Pages
- L55-L58
- ISSN
- 0022-3719 (ISSN-L)
- OpenAlex
- W2065113098
- Cited by
- 1,813
- References
- 3
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.