Multi-planar image formation using NMR spin echoes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A new method of two- or three-dimensional spin density imaging by nuclear magnetic resonance (NMR) is proposed, which exploits the properties of spin echoes in time-dependent magnetic field gradients. An analysis shows that simultaneous observation and differentiation of signals, arising from all spins distributed in a plane or set of planes within the specimen, is possible. The method is thus capable of producing visual pictures faster than previously described planar imaging methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kumar, A., Welti, D., & Ernst, R. R. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90224-3 · Cited by 311
Image formation in NMR by a selective irradiative process
Garroway, A. N., Grannell, P. K., & Mansfield, P. (1974) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/7/24/006 · Cited by 271
Self-citation"Diffraction" and microscopy in solids and liquids by NMR
Mansfield, P., & Grannell, P. K. (1975) · Physical Review B · doi:10.1103/physrevb.12.3618 · Cited by 266
Self-citation
Cited by
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551
Whalen, P. J., Rauch, S. L., Etcoff, N. L., McInerney, S. C., Lee, M. B., & Jenike, M. A. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-01-00411.1998 · Cited by 2,205
“Our Instascan software is a variant of the echo planar technique first described by Mansfield (1977).”
MethodSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Resting-state fMRI in the human connectome project
Smith, S. M., Beckmann, C. F., Andersson, J., Auerbach, E. J., Bijsterbosch, J., Douaud, G., Duff, E., Feinberg, D. A., Griffanti, L., Harms, M. P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.039 · Cited by 1,502
“Early HCP piloting utilised a combination of two accelerations — the multiband method described above, and “simultaneous image refocused” (SIR) (Feinberg et al., 2002), the combined technique being referred to as “multiplexed” EPI (Feinberg et al., 2010).”
MethodInfluentialCorrection for geometric distortion in echo planar images from B 0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,421
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Rauch, S. L., Whalen, P. J., Shin, L. M., McInerney, S. C., Macklin, M. L., Lasko, N. B., Orr, S. P., & Pitman, R. K. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(00)00828-3 · Cited by 1,111
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
The neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Functional connectomics from resting-state fMRI
Smith, S. M., Vidaurre, D., Beckmann, C. F., Glasser, M. F., Jenkinson, M., Miller, K. L., Nichols, T. E., Robinson, E. C., Salimi-Khorshidi, G., Woolrich, M. W., et al. (2013) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2013.09.016 · Cited by 952
A hitchhiker's guide to diffusion tensor imaging
Soares, J. M., Marques, P., Alves, V., & Sousa, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00031 · Cited by 893
“Besides being the most common approach, EPI images are very sensitive to other artifacts related with EPI characteristics such as field inhomogeneities at B0 (especially at higher fields), image blurring [also called Point-Spread Function (PSF) artifact], limited resolution from T2 and T2 ∗ signal decay during the signa…”
MethodInfluentialRedefining Radiology: A Review of Artificial Intelligence Integration in Medical Imaging
Najjar, R. (2023) · Diagnostics · doi:10.3390/diagnostics13172760 · Cited by 886
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Basic principles of diffusion-weighted imaging
Bammer, R. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00303-0 · Cited by 851
Optimized EPI for fMRI studies of the orbitofrontal cortex
Deichmann, R., Gottfried, J. A., Hutton, C., & Turner, R. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00073-9 · Cited by 821
“Gradient-echo echo planar imaging (EPI) ( Mansfield, 1977 ) is one of the most commonly used techniques for functional magnetic resonance imaging (fMRI).”
MethodMotion artifacts in MRI: A complex problem with many partial solutions
Zaitsev, M., Maclaren, J., & Herbst, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24850 · Cited by 774
Parametric Analysis of fMRI Data Using Linear Systems Methods
Cohen, M. S. (1997) · NeuroImage · doi:10.1006/nimg.1997.0278 · Cited by 714
Ojemann, J. G., Akbudak, E., Snyder, A. Z., McKinstry, R. C., Raichle, M. E., & Conturo, T. E. (1997) · NeuroImage · doi:10.1006/nimg.1997.0289 · Cited by 694
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Whalen, P. J., Bush, G., McNally, R. J., Wilhelm, S., McInerney, S. C., Jenike, M. A., & Rauch, S. L. (1998) · Biological Psychiatry · doi:10.1016/s0006-3223(98)00251-0 · Cited by 650
“Our Instascan software is a variant of the echoplanar technique first described by Mansfield (1977). Head stabilization was achieved using a plastic bite bar, molded to each subject’s dentition.”
MethodEcho-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Self-citationAn fMRI study of anterior cingulate function in posttraumatic stress disorder
Shin, L. M., Whalen, P. J., Pitman, R. K., Bush, G., Macklin, M. L., Lasko, N. B., Orr, S. P., McInerney, S. C., & Rauch, S. L. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(01)01215-x · Cited by 604
“Our Instascan software is a variant of the echoplanar technique first described by Mansfield (1977).”
MethodEcho-planar imaging of intravoxel incoherent motion.
Turner, R., Le Bihan, D., Maier, J., Vavrek, R., Hedges, L. K., & Pekar, J. (1990) · Radiology · doi:10.1148/radiology.177.2.2217777 · Cited by 581
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
Functional imaging of the monkey brain
Logothetis, N. K., Guggenberger, H., Peled, S., & Pauls, J. (1999) · Nature Neuroscience · doi:10.1038/9210 · Cited by 540
Cha, S., Knopp, E. A., Johnson, G., Wetzel, S. G., Litt, A. W., & Zagzag, D. (2002) · Radiology · doi:10.1148/radiol.2231010594 · Cited by 525
Evaluation of slice accelerations using multiband echo planar imaging at 3T
Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E., & Uğurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.055 · Cited by 514
Marciani, L., Gowland, P. A., Spiller, R. C., Manoj, P., Moore, R. J., Young, P., & Fillery-Travis, A. J. (2001) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.2001.280.6.g1227 · Cited by 502
“T purpose-built EPI scanner equipped with actively shielded gradients and a 50-cm-diameter birdcage coil.”
BackgroundInfluentialHighly Undersampled Magnetic Resonance Image Reconstruction via Homotopic $\ell_{0}$-Minimization
Trzasko, J., & Manduca, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.927346 · Cited by 490
The neural substrates of affective processing in depressed patients treated with venlafaxine
Davidson, R. J., Irwin, W., Anderle, M. J., & Kalin, N. H. (2003) · American Journal of Psychiatry · doi:10.1176/appi.ajp.160.1.64 · Cited by 487
High-Speed Spiral-Scan Echo Planar NMR Imaging-I
Ahn, C. B., Kim, J. H., & Cho, Z. H. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307732 · Cited by 487
Retrospective estimation and correction of physiological fluctuation in functional MRI
Hu, X., Le, T. H., Parrish, T., & Erhard, P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340211 · Cited by 475
Holland, D., Kuperman, J. M., & Dale, A. M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.044 · Cited by 471
Paramagnetic Water-Soluble Metallofullerenes Having the Highest Relaxivity for MRI Contrast Agents
Mikawa, M., Kato, H., Okumura, M., Narazaki, M., Kanazawa, Y., Miwa, N., & Shinohara, H. (2001) · Bioconjugate Chemistry · doi:10.1021/bc000136m · Cited by 462
Poser, B. A., Versluis, M. J., Hoogduin, J. M., & Norris, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20900 · Cited by 439
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433
Mahmoudi, M., Hosseinkhani, H., Hosseinkhani, M., Boutry, S., Simchi, A., Journeay, W. S., Subramani, K., & Laurent, S. (2011) · Chemical Reviews · doi:10.1021/cr1001832 · Cited by 418
Monitoring the patient's EEG during echo planar MRI
Ives, J. R., Warach, S., Schmitt, F., Edelman, R. R., & Schomer, D. L. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90156-p · Cited by 398
MR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask
Bitar, R., Leung, G., Perng, R., Tadros, S., Moody, A. R., Sarrazin, J., McGregor, C., Christakis, M., Symons, S., Nelson, A., et al. (2006) · RadioGraphics · doi:10.1148/rg.262055063 · Cited by 383
Weisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381
Farzaneh, F., Riederer, S. J., & Pelc, N. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140112 · Cited by 362
4 T-fMRI Study of Nonspatial Shifting of Selective Attention: Cerebellar and Parietal Contributions
Le, T. H., Pardo, J. V., & Hu, X. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.3.1535 · Cited by 361
Saturated double‐angle method for rapid B1+ mapping
Cunningham, C. H., Pauly, J. M., & Nayak, K. S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20896 · Cited by 353
Zaitsev, M., Hennig, J., & Speck, O. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20261 · Cited by 349
The physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Minematsu, K., Li, L., Sotak, C. H., Davis, M. A., & Fisher, M. (1992) · Stroke · doi:10.1161/01.str.23.9.1304 · Cited by 320
Shimony, J. S., McKinstry, R. C., Akbudak, E., Aronovitz, J. A., Snyder, A. Z., Lori, N. F., Cull, T. S., & Conturo, T. E. (1999) · Radiology · doi:10.1148/radiology.212.3.r99au51770 · Cited by 315
Arterial Spin-Labeling in Routine Clinical Practice, Part 1: Technique and Artifacts
Deibler, A. R., Pollock, J. M., Kraft, R. A., Tan, H., Burdette, J. H., & Maldjian, J. A. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1030 · Cited by 298
Divergence of fMRI and neural signals in V1 during perceptual suppression in the awake monkey
Maier, A., Wilke, M., Aura, C., Zhu, C., Ye, F. Q., & Leopold, D. A. (2008) · Nature Neuroscience · doi:10.1038/nn.2173 · Cited by 295
Single‐shot 3D imaging techniques improve arterial spin labeling perfusion measurements
Günther, M., Oshio, K., & Feinberg, D. A. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20580 · Cited by 293
Le Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010103 · Cited by 288
Limitations of temporal resolution in functional MRI
Kim, S., Richter, W., & Uǧurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370427 · Cited by 287
Single-scan multidimensional magnetic resonance
Tal, A., & Frydman, L. (2010) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2010.04.001 · Cited by 277
Image reconstruction for echo planar imaging with nonequidistant k‐space sampling
Bruder, H., Fischer, H., Reinfelder, H. ‐., & Schmitt, F. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230211 · Cited by 269
Twenty years of functional MRI: The science and the stories
Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.04.026 · Cited by 265
Marciani, L., Gowland, P. A., Moore, R. J., Young, P., Al-Sahab, S., Spiller, R. C., Manoj, P., Bush, D., Wright, J., & Fillery-Travis, A. J. (2000) · The Journal of Nutrition · doi:10.1093/jn/130.1.122 · Cited by 263
Engineered nanoparticles for biomolecular imaging
Mahmoudi, M., Serpooshan, V., & Laurent, S. (2011) · Nanoscale · doi:10.1039/c1nr10326a · Cited by 262
Principles and Features of Single-Scan Two-Dimensional NMR Spectroscopy
Frydman, L., Lupulescu, A., & Scherf, T. (2003) · Journal of the American Chemical Society · doi:10.1021/ja030055b · Cited by 259
Evaluation of the early response in fMRI in individual subjects using short stimulus duration
Hu, X., Le, T. H., & Uǧurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370612 · Cited by 255
Compensation of susceptibility-induced bold sensitivity losses in echo-planar fMRI imaging
Deichmann, R., Josephs, O., Hutton, C., Corfield, D. R., & Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2001.0985 · Cited by 253
The effect of daily caffeine use on cerebral blood flow: How much caffeine can we tolerate?
Addicott, M. A., Yang, L. L., Peiffer, A. M., Burnett, L. R., Burdette, J. H., Chen, M. Y., Hayasaka, S., Kraft, R. A., Maldjian, J. A., & Laurienti, P. J. (2009) · Human Brain Mapping · doi:10.1002/hbm.20732 · Cited by 210
“Images were acquired with a single shot gradient echo Echo Planar Imaging (EPI) sequence [Mansfield, 1977].”
MethodFunctional Magnetic Resonance Imaging Methods
Chen, J. E., & Glover, G. H. (2015) · Neuropsychology Review · doi:10.1007/s11065-015-9294-9 · Cited by 212
“Furthermore, acquisition methods are reasonably standardized by now with the use of single-shot EPI, although faster, more efficient methods such as SMS have been recently introduced.”
MethodMR Artifacts, Safety, and Quality Control
Zhuo, J., & Gullapalli, R. P. (2006) · RadioGraphics · doi:10.1148/rg.261055134 · Cited by 212
Wang, S., Peterson, D. J., Gatenby, J. C., Li, W., Grabowski, T. J., & Madhyastha, T. M. (2017) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2017.00017 · Cited by 207
“Echo planar imaging (EPI), introduced by Mansfield (1977), has become the dominant method for the acquisition of diffusion-weighted images, which are commonly fit to a tensor model as Diffusion Tensor Imaging (DTI).”
MethodA brief review of parallel magnetic resonance imaging
Heidemann, R. M., �zsarlak, �., Parizel, P. M., Michiels, J., Kiefer, B., Jellus, V., M�ller, M., Breuer, F., Blaimer, M., Griswold, M. A., et al. (2003) · European Radiology · doi:10.1007/s00330-003-1992-7 · Cited by 190
“imaging, single-shot imaging methods, such as EPI [1] or TSE imaging [3], acquire the entire image matrix after a single spin excitation; therefore, the maximum available spatial resolution is limited by signal attenuation due to T2 or T2* relaxation over the entire course”
BackgroundMethodOn the application of ultra‐fast rare experiments
Norris, D. G., Börnert, P., Reese, T., & Leibfritz, D. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270114 · Cited by 179
Functional Magnetic Resonance Imaging
Matthews, P. M., & Jezzard, P. (2006) · Neuroscience for Neurologists · doi:10.1142/9781860948961_0015 · Cited by 164
Casey, A., Mann, R., Banister, K., Fox, J., Morris, P. G., Macdonald, I. A., & Greenhaff, P. L. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.278.1.e65 · Cited by 140
Spreading waves of decreased diffusion coefficient lifter cortical stimulation in the rat brain
Latour, L. L., Hasegawa, Y., Formato, J. E., Fisher, M., & Sotak, C. H. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320207 · Cited by 136
Zhu, X., & Chen, W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1267 · Cited by 92
“Seven contiguous coronal images covering the calcarine fissure were acquired using the gradient echo-planar imaging sequence (64 3 64 image matrix size, 20 3 20 cm(2) FOV, 5 mm slice thickness, TE 5 25 ms, TR 5 2 sec) (22).”
MethodVan Steenkiste, G., Poot, D. H. J., Jeurissen, B., den Dekker, A. J., Vanhevel, F., Parizel, P. M., & Sijbers, J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26262 · Cited by 20
A CUDA-based reverse gridding algorithm for MR reconstruction
Yang, J., Feng, C., & Zhao, D. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.038 · Cited by 16
“Mansfield [12] devel-”
Metadata
- Authors
- Mansfield, P.
- Venue
- Journal of Physics C: Solid State Physics
- Publisher
- IOP Publishing
- Published
- 1977-02-14
- Volume
- 10
- Issue
- 3
- Pages
- L55-L58
- ISSN
- 0022-3719 (ISSN-L)
- OpenAlex
- W2065113098
- Cited by
- 1,813
- References
- 3
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.