The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Phase objects in synchrotron radiation hard x-ray imaging
Open accessAbstract
Phase objects are readily imaged through Fresnel diffraction in the hard x-ray beams of third-generation synchrotron radiation sources such as the ESRF, due essentially to the very small angular size of the source. Phase objects can lead to spurious contrast in x-ray diffraction images (topographs) of crystals. It is shown that this contrast can be eliminated through random phase plates, which provide an effective way of tailoring the angular size of the source. The possibilities of this very simple technique for imaging phase objects in the hard x-ray range are explored experimentally and discussed. They appear very promising, as shown in particular by the example of a piece of human vertebra, and could be extended to phase tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Studies of Solids by Total Reflection of X-Rays
Parratt, L. G. (1954) · Physical Review · doi:10.1103/physrev.95.359 · Cited by 5,188
Phase-contrast imaging of weakly absorbing materials using hard X-rays
Davis, T. J., Gao, D., Gureyev, T. E., Stevenson, A. W., & Wilkins, S. W. (1995) · Nature · doi:10.1038/373595a0 · Cited by 1,010
Principles of Statistical Radiophysics 3
Rytov, S. M., Kravtsov, Y. A., & Tatarskii, V. I. (1989) · Springer eBooks · doi:10.1007/978-3-642-72685-9 · Cited by 635
Spatial coherence of synchrotron radiation
Coisson, R. (1995) · Applied Optics · doi:10.1364/ao.34.000904 · Cited by 77
Cited by
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997) · Journal of Applied Physics · doi:10.1063/1.364374 · Cited by 538
Self-citationTafforeau, P., Boistel, R., Boller, E., Bravin, A., Brunet, M., Chaimanee, Y., Cloetens, P., Feist, M., Hoszowska, J., Jaeger, J.-J., et al. (2006) · Applied Physics A · doi:10.1007/s00339-006-3507-2 · Cited by 456
Self-citationDense neuronal reconstruction through X-ray holographic nano-tomography
Kuan, A. T., Phelps, J. S., Thomas, L. A., Nguyen, T. M., Han, J., Chen, C.-L., Azevedo, A. W., Tuthill, J. C., Funke, J., Cloetens, P., et al. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-0704-9 · Cited by 160
Self-citation
Metadata
- Authors
- Cloetens, P., Barrett, R., Baruchel, J., Guigay, J.-P., & Schlenker, M.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 1996-01-14
- Volume
- 29
- Issue
- 1
- Pages
- 133-146
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2029530660
- Cited by
- 853
- References
- 4
- FWCI
- 27.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phase objects in synchrotron radiation hard x-ray imaging. https://app.cochat.ai/papers/10.1088/0022-3727/29/1/023
- The paper
- Cloetens, P., Barrett, R., Baruchel, J., Guigay, J.-P., & Schlenker, M. (1996). Phase objects in synchrotron radiation hard x-ray imaging. Journal of Physics D: Applied Physics. https://doi.org/10.1088/0022-3727/29/1/023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.