Phase objects in synchrotron radiation hard x-ray imaging
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Phase objects are readily imaged through Fresnel diffraction in the hard x-ray beams of third-generation synchrotron radiation sources such as the ESRF, due essentially to the very small angular size of the source. Phase objects can lead to spurious contrast in x-ray diffraction images (topographs) of crystals. It is shown that this contrast can be eliminated through random phase plates, which provide an effective way of tailoring the angular size of the source. The possibilities of this very simple technique for imaging phase objects in the hard x-ray range are explored experimentally and discussed. They appear very promising, as shown in particular by the example of a piece of human vertebra, and could be extended to phase tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Studies of Solids by Total Reflection of X-Rays
Parratt, L. G. (1954) · Physical Review · doi:10.1103/physrev.95.359 · Cited by 5,188
Phase-contrast imaging of weakly absorbing materials using hard X-rays
Davis, T. J., Gao, D., Gureyev, T. E., Stevenson, A. W., & Wilkins, S. W. (1995) · Nature · doi:10.1038/373595a0 · Cited by 1,010
Principles of Statistical Radiophysics 3
Rytov, S. M., Kravtsov, Y. A., & Tatarskii, V. I. (1989) · Springer eBooks · doi:10.1007/978-3-642-72685-9 · Cited by 635
Spatial coherence of synchrotron radiation
Coisson, R. (1995) · Applied Optics · doi:10.1364/ao.34.000904 · Cited by 77
Cited by
Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object
Paganin, D., Mayo, S. C., Gureyev, T. E., Miller, P. R., & Wilkins, S. W. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01010.x · Cited by 2,062
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P., & Schlenker, M. (1999) · Applied Physics Letters · doi:10.1063/1.125225 · Cited by 1,078
Self-citationPtychographic X-ray computed tomography at the nanoscale
Dierolf, M., Menzel, A., Thibault, P., Schneider, P., Kewish, C. M., Wepf, R., Bunk, O., & Pfeiffer, F. (2010) · Nature · doi:10.1038/nature09419 · Cited by 926
Quantitative Phase Imaging Using Hard X Rays
Nugent, K. A., Gureyev, T. E., Cookson, D. F., Paganin, D., & Barnea, Z. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.2961 · Cited by 675
X-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997) · Journal of Applied Physics · doi:10.1063/1.364374 · Cited by 538
Self-citationRecent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
Coherent methods in the X-ray sciences
Nugent, K. A. (2010) · Advances in Physics · doi:10.1080/00018730903270926 · Cited by 476
Contrast and resolution in imaging with a microfocus x-ray source
Pogany, A., Gao, D., & Wilkins, S. W. (1997) · Review of Scientific Instruments · doi:10.1063/1.1148194 · Cited by 476
Tafforeau, P., Boistel, R., Boller, E., Bravin, A., Brunet, M., Chaimanee, Y., Cloetens, P., Feist, M., Hoszowska, J., Jaeger, J.-J., et al. (2006) · Applied Physics A · doi:10.1007/s00339-006-3507-2 · Cited by 456
Self-citationDynamical Theory of X-Ray Diffraction
Authier, A. (2003) · doi:10.1093/acprof:oso/9780198528920.001.0001 · Cited by 331
PITRE: software for phase-sensitive X-ray image processing and tomography reconstruction
Chen, R.-C., Dreossi, D., Mancini, L., Menk, R., Rigon, L., Xiao, T.-Q., & Longo, R. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512029731 · Cited by 279
ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs
Weitkamp, T., Haas, D., Wegrzynek, D., & Rack, A. (2011) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511002895 · Cited by 278
BETZ, O., WEGST, U., WEIDE, D., HEETHOFF, M., HELFEN, L., LEE, W., & CLOETENS, P. (2007) · Journal of Microscopy · doi:10.1111/j.1365-2818.2007.01785.x · Cited by 277
Self-citationA synchrotron radiation microtomography system for the analysis of trabecular bone samples
Salomé, M., Peyrin, F., Cloetens, P., Odet, C., Laval-Jeantet, A.-M., Baruchel, J., & Spanne, P. (1999) · Medical Physics · doi:10.1118/1.598736 · Cited by 275
Self-citationPhase retrieval in X-ray phase-contrast imaging suitable for tomography
Burvall, A., Lundström, U., Takman, P. A. C., Larsson, D. H., & Hertz, H. M. (2011) · Optics Express · doi:10.1364/oe.19.010359 · Cited by 263
Tracheal Respiration in Insects Visualized with Synchrotron X-ray Imaging
Westneat, M. W., Betz, O., Blob, R. W., Fezzaa, K., Cooper, W. J., & Lee, W.-K. (2003) · Science · doi:10.1126/science.1078008 · Cited by 248
Nuzzo, S., Peyrin, F., Cloetens, P., Baruchel, J., & Boivin, G. (2002) · Medical Physics · doi:10.1118/1.1513161 · Cited by 233
Self-citationBaker, D. R., Mancini, L., Polacci, M., Higgins, M. D., Gualda, G. A. R., Hill, R. J., & Rivers, M. L. (2012) · Lithos · doi:10.1016/j.lithos.2012.06.008 · Cited by 227
“Compared with absorption mode images, where the objects are imaged in the near-field (or edge-detection) regime of Fresnel diffraction (Cloetens et al., 1996), they appear sharper and very small details can be detected (even smaller than the pixel size of the detector).”
BackgroundThe imaging of failure in structural materials by synchrotron radiation X-ray microtomography
Wu, S. C., Xiao, T. Q., & Withers, P. J. (2017) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2017.07.027 · Cited by 225
Rack, A., Zabler, S., Müller, B. R., Riesemeier, H., Weidemann, G., Lange, A., Goebbels, J., Hentschel, M., & Görner, W. (2008) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.11.020 · Cited by 193
Quantitative phase tomography of Arabidopsis seeds reveals intercellular void network
Cloetens, P., Mache, R., Schlenker, M., & Lerbs-Mache, S. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0603490103 · Cited by 188
Self-citation2D and 3D X-ray phase retrieval of multi-material objects using a single defocus distance
Beltran, M. A., Paganin, D. M., Uesugi, K., & Kitchen, M. J. (2010) · Optics Express · doi:10.1364/oe.18.006423 · Cited by 187
Quantitative comparison of direct phase retrieval algorithms in in‐line phase tomography
Langer, M., Cloetens, P., Guigay, J., & Peyrin, F. (2008) · Medical Physics · doi:10.1118/1.2975224 · Cited by 179
Self-citationFast microtomography using high energy synchrotron radiation
Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martins, T., & Svensson, O. (2005) · Review of Scientific Instruments · doi:10.1063/1.1884194 · Cited by 169
Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam
Cloetens, P., Ludwig, W., Baruchel, J., Guigay, J.-P., Pernot-Rejmánková, P., Salomé-Pateyron, M., Schlenker, M., Buffière, J.-Y., Maire, E., & Peix, G. (1999) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/32/10a/330 · Cited by 162
Self-citationDense neuronal reconstruction through X-ray holographic nano-tomography
Kuan, A. T., Phelps, J. S., Thomas, L. A., Nguyen, T. M., Han, J., Chen, C.-L., Azevedo, A. W., Tuthill, J. C., Funke, J., Cloetens, P., et al. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-0704-9 · Cited by 160
“From these sets of aligned holograms, phase maps were obtained through an iterative algorithm 21,58–60 .”
Self-citation
Metadata
- Authors
- Cloetens, P., Barrett, R., Baruchel, J., Guigay, J.-P., & Schlenker, M.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 1996-01-14
- Volume
- 29
- Issue
- 1
- Pages
- 133-146
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2029530660
- Cited by
- 853
- References
- 4
- FWCI
- 27.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.