Optical clearing of tissues and blood using the immersion method
The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
This paper aims to review recent results on the optical clearing of the naturally turbid biological tissues and blood using the optical immersion technique, which is well known in physical science and is applied for the reduction of light scattering and undesirable reflections in the optical system. Basic principles of the technique, its advantages, limitations and future are discussed. The refractive index matching concept for enhancement of in-depth light penetration into tissues and blood is presented on the basis of in vitro and in vivo studies using optical spectroscopy, polarization and coherence-domain techniques. The index matching of scatterers and ground matter by means of administration of clearing agents is under discussion. The optical properties of tissues with basic multiple scattering, which are transformed to a low scattering mode, are analysed. It is shown that light reflection, transmission, scattering and polarization can be effectively controlled. The possibilities of using the optical immersion method for diagnostic purposes based on contrasting of abnormalities, on in-depth profiling of tissue and blood and on monitoring of endogenous and exogenous matter diffusion within tissue are demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis
Tuchin, V. V. (2015) · SPIE eBooks · doi:10.1117/3.1003040 · Cited by 1,352
Self-citationOptical Properties of Circulating Human Blood in the Wavelength Range 400–2500 nm
Roggan, A., Friebel, M., Dörschel, K., Hahn, A., & Müller, G. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429919 · Cited by 819 · cited 5×
“The scattering properties of blood are also dependent on erythrocyte volume and shape, which are defined by blood plasma osmolarity, and aggregation or disaggregation capability [84, 85].”
BackgroundInfluentialVo-Dinh, T., & Masters, B. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1776177 · Cited by 761
(2003) · CRC Press eBooks · doi:10.1201/9780203008997 · Cited by 605
Handbook of Optical Biomedical Diagnostics
Tuchin, V. V. (2002) · Medical Entomology and Zoology · Cited by 589
Self-citationHandbook of Optical Coherence Tomography
(2001) · CRC Press eBooks · doi:10.1201/b14024 · Cited by 580
Skin barrier : principles of percutaneous absorption
Schaefer, H. E., & Redelmeier, T. E. (1996) · Cited by 565
Light propagation in tissues with controlled optical properties
Tuchin, V. V. (1997) · Journal of Biomedical Optics · doi:10.1117/1.429841 · Cited by 411
Self-citationOptical scattering properties of soft tissue: a discrete particle model
Schmitt, J. M., & Kumar, G. (1998) · Applied Optics · doi:10.1364/ao.37.002788 · Cited by 408
Polarization-Modulated Second Harmonic Generation in Collagen
Stoller, P., Reiser, K. M., Celliers, P. M., & Rubenchik, A. M. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75673-7 · Cited by 400 · cited 1×
“Collagen has been shown to have a dominant uniaxial secondorder nonlinear susceptibility component aligned along the fibre axis [129].”
Background
Cited by
Second Harmonic Generation Imaging Microscopy: Applications to Diseases Diagnostics
Campagnola, P. (2011) · Analytical Chemistry · doi:10.1021/ac1032325 · Cited by 410
Recent progress in tissue optical clearing
Zhu, D., Larin, K. V., Luo, Q., & Tuchin, V. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200056 · Cited by 394
Self-citationPolarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
Self-citationDing, H., Lu, J. Q., Wooden, W. A., Kragel, P. J., & Hu, X.-H. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/6/008 · Cited by 291
Advanced CUBIC tissue clearing for whole-organ cell profiling
Matsumoto, K., Mitani, T. T., Horiguchi, S. A., Kaneshiro, J., Murakami, T. C., Mano, T., Fujishima, H., Konno, A., Watanabe, T. M., Hirai, H., et al. (2019) · Nature Protocols · doi:10.1038/s41596-019-0240-9 · Cited by 277
Second harmonic generation microscopy: principles and applications to disease diagnosis
Campagnola, P. J., & Dong, C. ‐. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.200910024 · Cited by 226
Tissue optical immersion clearing
Genina, E. A., Bashkatov, A. N., & Tuchin, V. V. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.50 · Cited by 208
Self-citationIn-vivo and ex-vivo optical clearing methods for biological tissues: review
Costantini, I., Cicchi, R., Silvestri, L., Vanzi, F., & Pavone, F. S. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.005251 · Cited by 207
Metadata
- Authors
- Tuchin, V. V.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2005-07-22
- Volume
- 38
- Issue
- 15
- Pages
- 2497-2518
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W1974608172
- Cited by
- 232
- References
- 71
- FWCI
- 10.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.