The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
CCD-based thermoreflectance microscopy: principles and applications
Abstract
CCD-based thermoreflectance microscopy has emerged as a high resolution, non-contact imaging technique for thermal profiling and performance and reliability analysis of numerous electronic and optoelectronic devices at the micro-scale. This thermography technique, which is based on measuring the relative change in reflectivity of the device surface as a function of change in temperature, provides high-resolution thermal images that are useful for hot spot detection and failure analysis, mapping of temperature distribution, measurement of thermal transient, optical characterization of photonic devices and measurement of thermal conductivity in thin films. In this paper we review the basic physical principle behind thermoreflectance as a thermography tool, discuss the experimental setup, resolutions achieved, signal processing procedures and calibration techniques, and review the current applications of CCD-based thermoreflectance microscopy in various devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gammaitoni, L., Hänggi, P., Jung, P., & Marchesoni, F. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.223 · Cited by 5,443
Stochastic Resonance: From Suprathreshold Stochastic Resonance to Stochastic Signal Quantization
McDonnell, M. D., Stocks, N. G., Pearce, C. E. M., & Abbott, D. (2008) · Cambridge University Press eBooks · doi:10.1017/cbo9780511535239 · Cited by 2,403
Thermal conductivity measurement from 30 to 750 K: the 3ω method
Cahill, D. G. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141498 · Cited by 1,928 · cited 1×
“For example, the 3ω technique has become a standard electrical method for determining thermal conductivities of thin and bulk materials [72].”
MethodTemperature - Its measurement and control in science and industry
(1973) · Cryogenics · doi:10.1016/0011-2275(73)90253-1 · Cited by 1,027
Transient thermoreflectance from thin metal films
Paddock, C. A., & Eesley, G. L. (1986) · Journal of Applied Physics · doi:10.1063/1.337642 · Cited by 528
Temperature-Its Measurement and Control
RK, &. (1941) · The American Journal of the Medical Sciences · doi:10.1097/00000441-194111000-00031 · Cited by 371
Thermoreflectance in Semiconductors
Matatagui, E., Thompson, A. G., & Cardona, M. (1968) · Physical Review · doi:10.1103/physrev.176.950 · Cited by 284
Temperature, Its Measurement and Control in Science and Industry
&NA; (1941) · Soil Science · doi:10.1097/00010694-194105000-00014 · Cited by 198
Microscale and Nanoscale Thermal Characterization Techniques
Christofferson, J., Maize, K., Ezzahri, Y., Shabani, J., Wang, X., & Shakouri, A. (2008) · Journal of Electronic Packaging · doi:10.1115/1.2993145 · Cited by 158
Self-citationTessier, G., Holé, S., & Fournier, D. (2001) · Applied Physics Letters · doi:10.1063/1.1363696 · Cited by 157
Cited by
Lanthanides in Luminescent Thermometry
Brites, C. D. S., Millán, A., & Carlos, L. D. (2016) · Handbook on the Physics and Chemistry of Rare Earths · doi:10.1016/bs.hpcre.2016.03.005 · Cited by 536
Favaloro, T., Bahk, J.-H., & Shakouri, A. (2015) · Review of Scientific Instruments · doi:10.1063/1.4907354 · Cited by 127
Self-citation
Metadata
- Authors
- Farzaneh, M., Maize, K., Lüerßen, D., Summers, J. A., Mayer, P. M., Raad, P. E., Pipe, K. P., Shakouri, A., Ram, R. J., & Hudgings, J. A.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2009-06-29
- Volume
- 42
- Issue
- 14
- Pages
- 143001
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W1969018186
- Cited by
- 276
- References
- 29
- FWCI
- 14.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CCD-based thermoreflectance microscopy: principles and applications. https://app.cochat.ai/papers/10.1088/0022-3727/42/14/143001
- The paper
- Farzaneh, M., Maize, K., Lüerßen, D., Summers, J. A., Mayer, P. M., Raad, P. E., Pipe, K. P., Shakouri, A., Ram, R. J., & Hudgings, J. A. (2009). CCD-based thermoreflectance microscopy: principles and applications. Journal of Physics D: Applied Physics. https://doi.org/10.1088/0022-3727/42/14/143001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.