The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
NMR microscopy of dynamic displacements: k-space and q-space imaging
Open accessAbstract
The superposition of pulsed gradient spin-echo (PGSE) and NMR imaging experiments results in a spin density image which is phase and amplitude modulated according to the local self-correlation function for nuclear spin displacements over the time between the PGSE gradient pulses. It is shown that such an experiment can image both static and dynamic spin displacements, the reciprocal space for these image spaces being termed k-space and q-space respectively. Simultaneous imaging of diffusion and flow at microscopic resolution is demonstrated and the Poiseuille velocity distribution agrees well with the velocity map obtained for the motion of water in a 0.7 mm capillary tube.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Stejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894
Mansfield, P., & Grannell, P. K. (1973) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/6/22/007 · Cited by 551
The spatial mapping of translational diffusion coefficients by the NMR imaging technique
Taylor, D. G., & Bushell, M. C. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/009 · Cited by 344
Nuclear magnetic resonance imaging of a single cell
Aguayo, J. B., Blackband, S. J., Schoeniger, J. S., Mattingly, M. A., & Hintermann, M. (1986) · Nature · doi:10.1038/322190a0 · Cited by 327
"Diffraction" and microscopy in solids and liquids by NMR
Mansfield, P., & Grannell, P. K. (1975) · Physical Review B · doi:10.1103/physrevb.12.3618 · Cited by 266
NMR blood flow imaging using multiecho, phase contrast sequences
O'Donnell, M. (1985) · Medical Physics · doi:10.1118/1.595736 · Cited by 158
High-resolution imaging. The NMR microscope
Eccles, C. D., & Callaghan, P. T. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90261-1 · Cited by 118
Self-citation
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Tournier, J.-D., Calamante, F., & Connelly, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.016 · Cited by 2,188
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Basser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Metadata
- Authors
- Callaghan, P. T., Eccles, C. D., & Xia, Y.
- Venue
- Journal of Physics E: Scientific Instruments
- Publisher
- IOP Publishing
- Published
- 1988-08
- Volume
- 21
- Issue
- 8
- Pages
- 820-822
- ISSN
- 0022-3735 (ISSN-L)
- OpenAlex
- W2023607973
- Cited by
- 298
- References
- 8
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.