NMR microscopy of dynamic displacements: k-space and q-space imaging
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The superposition of pulsed gradient spin-echo (PGSE) and NMR imaging experiments results in a spin density image which is phase and amplitude modulated according to the local self-correlation function for nuclear spin displacements over the time between the PGSE gradient pulses. It is shown that such an experiment can image both static and dynamic spin displacements, the reciprocal space for these image spaces being termed k-space and q-space respectively. Simultaneous imaging of diffusion and flow at microscopic resolution is demonstrated and the Poiseuille velocity distribution agrees well with the velocity map obtained for the motion of water in a 0.7 mm capillary tube.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Stejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894
Mansfield, P., & Grannell, P. K. (1973) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/6/22/007 · Cited by 551
Nuclear magnetic resonance imaging of a single cell
Aguayo, J. B., Blackband, S. J., Schoeniger, J. S., Mattingly, M. A., & Hintermann, M. (1986) · Nature · doi:10.1038/322190a0 · Cited by 354
The spatial mapping of translational diffusion coefficients by the NMR imaging technique
Taylor, D. G., & Bushell, M. C. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/009 · Cited by 344
"Diffraction" and microscopy in solids and liquids by NMR
Mansfield, P., & Grannell, P. K. (1975) · Physical Review B · doi:10.1103/physrevb.12.3618 · Cited by 266
NMR blood flow imaging using multiecho, phase contrast sequences
O'Donnell, M. (1985) · Medical Physics · doi:10.1118/1.595736 · Cited by 158
High-resolution imaging. The NMR microscope
Eccles, C. D., & Callaghan, P. T. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90261-1 · Cited by 140
Self-citation
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Tournier, J.-D., Calamante, F., & Connelly, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.016 · Cited by 2,188
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Basser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Dipy, a library for the analysis of diffusion MRI data
Garyfallidis, E., Brett, M., Amirbekian, B., Rokem, A., van der Walt, S., Descoteaux, M., Nimmo-Smith, I., & Contributors, D. (2014) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2014.00008 · Cited by 1,371
“In practice, the first methods to calculate the PDF were q-space imaging (QSI) (Callaghan et al., 1988) and the most recent diffusion spectrum imaging (DSI) (Wedeen et al., 2005) (see section 6.2).”
MethodInfluentialDiffusion MRI of complex neural architecture.
Tuch, D. S., Reese, T. G., Wiegell, M. R., & Wedeen, V. J. (2003) · Neuron · doi:10.1016/s0896-6273(03)00758-x · Cited by 698
Tournier, J.-D., Yeh, C.-H., Calamante, F., Cho, K.-H., Connelly, A., & Lin, C.-P. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.002 · Cited by 593
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Nuclear Magnetic Resonance of Laser-Polarized Noble Gases in Molecules, Materials, and Organisms
Goodson, B. M. (2002) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2341 · Cited by 457
Measurement of translational displacement probabilities by NMR: An indicator of compartmentation
Cory, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140303 · Cited by 429
Özarslan, E., Koay, C. G., Shepherd, T. M., Komlosh, M. E., İrfanoğlu, M. O., Pierpaoli, C., & Basser, P. J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.016 · Cited by 389
Q‐ball reconstruction of multimodal fiber orientations using the spherical harmonic basis
Hess, C. P., Mukherjee, P., Han, E. T., Xu, D., & Vigneron, D. B. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20931 · Cited by 366
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
The Human Connectome Project and beyond: Initial applications of 300mT/m gradients
McNab, J. A., Edlow, B. L., Witzel, T., Huang, S. Y., Bhat, H., Heberlein, K., Feiweier, T., Liu, K., Keil, B., Cohen-Adad, J., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.074 · Cited by 359
Alexander, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21646 · Cited by 331
Cohen, Y., & Assaf, Y. (2002) · NMR in Biomedicine · doi:10.1002/nbm.778 · Cited by 270
Novikov, D. S., Veraart, J., Jelescu, I. O., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.006 · Cited by 237
Lin, C.-P., Wedeen, V. J., Chen, J.-H., Yao, C., & Tseng, W.-Y. I. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00154-x · Cited by 225
“It samples multiple diffusion-attenuated images with different spatial modulations of magnetization generated by diffusion-sensitive gradients (Callaghan et al., 1988; Cory and Garroway, 1990; Callaghan, 1991; Callaghan et al., 1991).”
BackgroundTE dependent Diffusion Imaging (TEdDI) distinguishes between compartmental T2 relaxation times
Veraart, J., Novikov, D. S., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.09.030 · Cited by 212
Modelling white matter with spherical deconvolution: How and why?
Dell'Acqua, F., & Tournier, J. ‐. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3945 · Cited by 206
“1 | Q‐space A full description of the q‐space formalism is available from other articles in this special issue, and will not be repeated here.(17,32,33) However, it is helpful to discuss those aspects that relate specifically to fibre orientation estimation.”
MethodPoupon, C., Rieul, B., Kezele, I., Perrin, M., Poupon, F., & Mangin, J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21789 · Cited by 197
On the scaling behavior of water diffusion in human brain white matter
Veraart, J., Fieremans, E., & Novikov, D. S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.075 · Cited by 141
The sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
The tensor distribution function
Leow, A. D., Zhu, S., Zhan, L., McMahon, K., de Zubicaray, G. I., Meredith, M., Wright, M. J., Toga, A. W., & Thompson, P. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21852 · Cited by 101
Yang, J. Y.-M., Yeh, C.-H., Poupon, C., & Calamante, F. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac0d90 · Cited by 80
Hutchinson, E. B., Avram, A. V., Irfanoglu, M. O., Koay, C. G., Barnett, A. S., Komlosh, M. E., Özarslan, E., Schwerin, S. C., Juliano, S. L., & Pierpaoli, C. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26575 · Cited by 73
“Several modeling approaches are rooted in the q-space framework (6,7) and relate the measured signal by Fourier transformation to the 3D probability distribution of water displacement, known as the diffusion propagator.”
Metadata
- Authors
- Callaghan, P. T., Eccles, C. D., & Xia, Y.
- Venue
- Journal of Physics E: Scientific Instruments
- Publisher
- IOP Publishing
- Published
- 1988-08
- Volume
- 21
- Issue
- 8
- Pages
- 820-822
- ISSN
- 0022-3735 (ISSN-L)
- OpenAlex
- W2023607973
- Cited by
- 298
- References
- 8
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.