Abstract
A new primary frequency standard, the atomic caesium fountain CSF1, has been put into operation at the Physikalisch-Technische Bundesanstalt (PTB). 133 Cs atoms are cooled in a magneto-optical trap and in optical molasses. They are launched to a height of 39 cm above the microwave cavity centre. The resulting Ramsey resonance signal has a full-width half-maximum linewidth (FWHM) of 0.88 Hz. The first uncertainty evaluation yields a relative 1 σ frequency uncertainty of 1.4 × 10 −15 . The short-term relative frequency instability of the CSF1 for averaging time τ is typically 3.5 × 10 −13 (τ/s) −1/2, dictated by the available quartz oscillator as the local frequency source.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Quantum Physics of Atomic Frequency Standards: Recent Developments
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 553
Ramsey Resonance in a Zacharias Fountain
Clairon, A., Salomon, C., Guellati, S., & Phillips, W. D. (1991) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/16/2/008 · Cited by 223
Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain
Simon, E., Laurent, P., & Clairon, A. (1998) · Physical Review A · doi:10.1103/physreva.57.436 · Cited by 131
Ghezali, S., Laurent, P., Lea, S. N., & Clairon, A. (1996) · Europhysics Letters (EPL) · doi:10.1209/epl/i1996-00182-9 · Cited by 106
Spin-exchange frequency shift in a cesium atomic fountain
Tiesinga, E., VERHAAR, B. J., Stoof, H. T. C., & van Bragt, D. D. B. (1992) · Physical Review A · doi:10.1103/physreva.45.r2671 · Cited by 90
Frequency pulling by hyperfine σ transitions in cesium beam atomic frequency standards
Cutler, L. S., Flory, C. A., Giffard, R. P., & Marchi, A. D. (1991) · Journal of Applied Physics · doi:10.1063/1.348637 · Cited by 55
Frequency shifts in a cesium atomic clock due to Majorana transitions
Bauch, A., & Schröder, R. (1993) · Annalen der Physik · doi:10.1002/andp.19935050502 · Cited by 43
Self-citationWeyers, S., Bauch, A., Hübner, U., Schröder, R., & Tamm, C. (2000) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.827431 · Cited by 28
Self-citation
Cited by
Atomic clocks based on coherent population trapping: a review
Vanier, J. (2005) · Applied Physics B · doi:10.1007/s00340-005-1905-3 · Cited by 669
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Accuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C., Levi, F., Costanzo, G., Marchi, A. D., Drullinger, R., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Soffel, M., Klioner, S. A., Petit, G., Wolf, P., Kopeikin, S. M., Bretagnon, P., Brumberg, V. A., Capitaine, N., Damour, T., Fukushima, T., et al. (2003) · The Astronomical Journal · doi:10.1086/378162 · Cited by 392
“At present, the best accuracies are reached by cesium-fountain clocks operating at less than 2 parts in 1015 in fractional frequency (Lemonde et al. 2001; Weyers et al. 2001).”
BackgroundWynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
Self-citation
Metadata
- Authors
- Weyers, S., H bner, U., Schr der, R., Tamm, C., & Bauch, A.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2001-08
- Volume
- 38
- Issue
- 4
- Pages
- 343-352
- ISSN
- 0026-1394 (ISSN-L)
- OpenAlex
- W2057605851
- Cited by
- 160
- References
- 8
- FWCI
- 8.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.