CoChat

Uncertainty evaluation of the atomic caesium fountain CSF1 of the PTB

Open access
Weyers, S, H bner, U, Schr der, R, Tamm, Chr, Bauch, A · 2001 · Metrologia
Cited by 160

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

A new primary frequency standard, the atomic caesium fountain CSF1, has been put into operation at the Physikalisch-Technische Bundesanstalt (PTB). 133 Cs atoms are cooled in a magneto-optical trap and in optical molasses. They are launched to a height of 39 cm above the microwave cavity centre. The resulting Ramsey resonance signal has a full-width half-maximum linewidth (FWHM) of 0.88 Hz. The first uncertainty evaluation yields a relative 1 σ frequency uncertainty of 1.4 × 10 −15 . The short-term relative frequency instability of the CSF1 for averaging time τ is typically 3.5 × 10 −13 (τ/s) −1/2, dictated by the available quartz oscillator as the local frequency source.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/38/4/7

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Weyers, S., H bner, U., Schr der, R., Tamm, C., & Bauch, A.
Venue
Metrologia
Published
2001-08
Volume
38
Issue
4
Pages
343-352
ISSN
0026-1394 (ISSN-L)
OpenAlex
W2057605851
Cited by
160
References
8
FWCI
8.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.