Accuracy evaluation of NIST-F1
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The evaluation procedure of a new laser-cooled caesium fountain primary frequency standard developed at the National Institute of Standards and Technology (NIST) is described. The new standard, NIST-F1, is described in some detail and typical operational parameters are discussed. Systematic frequency biases for which corrections are made - second-order Zeeman shift, black-body radiation shift, gravitational red shift and spin-exchange shift - are discussed in detail. Numerous other frequency shifts are evaluated, but are so small in this type of standard that corrections are not made for their effects. We also discuss comparisons of this standard both with local frequency standards and with standards at other national laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Quantum Physics of Atomic Frequency Standards: Recent Developments
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 553
Gibble, K., & Chu, S. (1993) · Physical Review Letters · doi:10.1103/physrevlett.70.1771 · Cited by 263
Shift ofS122hyperfine splittings due to blackbody radiation
Itano, W. M., Lewis, L. L., & Wineland, D. J. (1982) · Physical Review A · doi:10.1103/physreva.25.1233 · Cited by 219
Arditi, M., & Carver, T. R. (1961) · Physical Review · doi:10.1103/physrev.124.800 · Cited by 174
Uncertainty evaluation of the atomic caesium fountain CSF1 of the PTB
Weyers, S., H bner, U., Schr der, R., Tamm, C., & Bauch, A. (2001) · Metrologia · doi:10.1088/0026-1394/38/4/7 · Cited by 160
Measurement and Cancellation of the Cold Collision Frequency Shift in an87RbFountain Clock
Fertig, C., & Gibble, K. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.1622 · Cited by 135
Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain
Simon, E., Laurent, P., & Clairon, A. (1998) · Physical Review A · doi:10.1103/physreva.57.436 · Cited by 131
Ghezali, S., Laurent, P., Lea, S. N., & Clairon, A. (1996) · Europhysics Letters (EPL) · doi:10.1209/epl/i1996-00182-9 · Cited by 106
Accuracy evaluation of the primary frequency standard NIST-7
Shirley, J. H., Lee, W. D., & Drullinger, R. E. (2001) · Metrologia · doi:10.1088/0026-1394/38/5/7 · Cited by 93
Self-citationCollisional Frequency Shifts in133CsFountain Clocks
Leo, P. J., Julienne, P. S., Mies, F. H., & Williams, C. J. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.3743 · Cited by 64
Frequency pulling by hyperfine σ transitions in cesium beam atomic frequency standards
Cutler, L. S., Flory, C. A., Giffard, R. P., & Marchi, A. D. (1991) · Journal of Applied Physics · doi:10.1063/1.348637 · Cited by 55
Self-citationBauch, A., & Schröder, R. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.622 · Cited by 50
Frequency shifts in a cesium atomic clock due to Majorana transitions
Bauch, A., & Schröder, R. (1993) · Annalen der Physik · doi:10.1002/andp.19935050502 · Cited by 41
Environmental factors and hydrogen maser frequency stability
Parker, T. E. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.764861 · Cited by 26
Self-citationRelativistic red shift with 1 10 16 uncertainty at the NIST, Boulder
Weiss, M. A., & Ashby, N. (2000) · Metrologia · doi:10.1088/0026-1394/37/6/10 · Cited by 6
Cited by
Wynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationSingle-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Self-citationDouble-pass acousto-optic modulator system
Donley, E. A., Heavner, T. P., Levi, F., Tataw, M. O., & Jefferts, S. R. (2005) · Review of Scientific Instruments · doi:10.1063/1.1930095 · Cited by 234
Self-citationComparison between frequency standards in Europe and the USA at the 10−15uncertainty level
Bauch, A., Achkar, J., Bize, S., Calonico, D., Dach, R., Hlavać, R., Lorini, L., Parker, T., Petit, G., Piester, D., et al. (2006) · Metrologia · doi:10.1088/0026-1394/43/1/016 · Cited by 225
Self-citation
Metadata
- Authors
- Jefferts, S. R., Shirley, J., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C., Levi, F., Costanzo, G., Marchi, A. D., Drullinger, R., Hollberg, L., Lee, W. D., & Walls, F. L.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2002-08-01
- Volume
- 39
- Issue
- 4
- Pages
- 321-336
- ISSN
- 0026-1394 (ISSN-L)
- OpenAlex
- W2126289687
- Cited by
- 402
- References
- 15
- FWCI
- 19.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.