Practical realization of the definition of the metre, including recommended radiations of other optical frequency standards (2001)
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
In 1983, at the time of the adoption of the present definition of the metre by the 17th General Conference on Weights and Measures (CGPM), the International Committee for Weights and Measures (CIPM) drew up recommendations for the practical realization of the definition. These have formerly been referred to as the mise en pratique of the definition of the metre. It was understood that the practical realization would, from time to time, be updated to take account of new measurements and improvements in techniques of laser stabilization. In 1992 the CIPM, acting on the advice of the then Consultative Committee for the Definition of the Metre (CCDM), adopted a revision of the mise en pratique in its Recommendation 3 (CI-1992). The text was published in Metrologia (1993/94 30 523–41). In 1997 a second revised version of the practical realization of the definition of the metre was adopted by the CIPM in its Recommendation 1 (CI-1997). The text was published in Metrologia (1999 36 211–44). In 2001, the CIPM again adopted a revised version of the practical realization of the metre and this time included recommended frequencies for other optical frequency standards. The text of this Recommendation (Recommendation 1 (CI-2002)) is given here∗. In addition, a revised list of recommended radiations, and an appendix containing the source data used in estimating the wavelengths, frequencies and uncertainties of the recommended radiations are given. In adopting the revised practical realization, the CIPM acknowledged the considerable effort put into its preparation by the Consultative Committee for Length (CCL) through its Working Group on the mise en
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Direct Link between Microwave and Optical Frequencies with a 300 THz Femtosecond Laser Comb
Diddams, S. A., Jones, D. J., Ye, J., Cundiff, S. T., Hall, J. L., Ranka, J. K., Windeler, R. S., Holzwarth, R., Udem, T., & Hänsch, T. W. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5102 · Cited by 1,155
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Udem, T., Huber, A., Gross, B., Reichert, J., Prevedelli, M., Weitz, M., & Hänsch, T. W. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.2646 · Cited by 357
Accurate optical frequency atlas of the 15-µm bands of acetylene
Nakagawa, K., de Labachelerie, M., Awaji, Y., & Kourogi, M. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.002708 · Cited by 264
Absolute Frequency Measurements of theHg+and Ca Optical Clock Transitions with a Femtosecond Laser
Udem, T., Diddams, S. A., Vogel, K. R., Oates, C. W., Curtis, E. A., Lee, W. D., Itano, W. M., Drullinger, R. E., Bergquist, J. C., & Hollberg, L. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4996 · Cited by 260
Documents Concerning the New Definition of the Metre
(1984) · Metrologia · doi:10.1088/0026-1394/19/4/004 · Cited by 216
de Beauvoir, B., Nez, F., Julien, L., Cagnac, B., Biraben, F., Touahri, D., Hilico, L., Acef, O., Clairon, A., & Zondy, J. J. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.440 · Cited by 207
Ye, J., Ma, L. S., & Hall, J. L. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.270801 · Cited by 206
Bernard, J. E., Madej, A. A., Marmet, L., Whitford, B. G., Siemsen, K. J., & Cundy, S. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3228 · Cited by 148
Frequency measurement of the two-photon transition in rubidium
Touahri, D., Acef, O., Clairon, A., Zondy, J. ‐., Felder, R., Hilico, L., de Beauvoir, B., Biraben, F., & Nez, F. (1997) · Optics Communications · doi:10.1016/s0030-4018(96)00471-3 · Cited by 145
Practical realization of the definition of the metre (1997)
Quinn, T. J. (1999) · Metrologia · doi:10.1088/0026-1394/36/3/7 · Cited by 141
Self-citationAbsolute frequency atlas of molecular I/sub 2/ lines at 532 nm
Ye, J., Robertsson, L., Picard, S., Ma, L.-S., & Hall, J. L. (1999) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.769654 · Cited by 135
Stenger, J., Tamm, C., Haverkamp, N., Weyers, S., & Telle, H. R. (2001) · Optics Letters · doi:10.1364/ol.26.001589 · Cited by 129
Absolute frequency measurement of the In^+ clock transition with a mode-locked laser
von Zanthier, J., Becker, T., Eichenseer, M., Nevsky, A. Y., Schwedes, C., Peik, E., Walther, H., Holzwarth, R., Reichert, J., Udem, T., et al. (2000) · Optics Letters · doi:10.1364/ol.25.001729 · Cited by 119
Bordé, C. J., Camy, G., Decomps, B., Descoubes, J. P., & Vigué, J. (1981) · Journal de physique · doi:10.1051/jphys:0198100420100139300 · Cited by 93
Absolute frequency measurement of the $In^{+}$ clock transition with a mode-locked laser
Von Zanthier, J., Becker, T., Eichenseer, M., et al. (2000) · CERN Document Server (European Organization for Nuclear Research) · Cited by 91
Ye, J., Yoon, T. H., Hall, J. L., Madej, A. A., Bernard, J. E., Siemsen, K. J., Marmet, L., Chartier, J., & Chartier, A. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3797 · Cited by 81
Absolute frequency of the molecular iodine transition R(56)32-0 near 532 nm
Jungner, P., Swartz, S. D., Eickhoff, M., Ye, J., Hall, J. L., & Waltman, S. B. (1995) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.377796 · Cited by 79
Margolis, H. S., Huang, G., Barwood, G. P., Lea, S. N., Klein, H. A., Rowley, W. R. C., Gill, P., & Windeler, R. S. (2003) · Physical Review A · doi:10.1103/physreva.67.032501 · Cited by 76
Frequency comparison and absolute frequency measurement of I2-stabilized lasers at 532 nm
Nevsky, A. Y., Holzwarth, R., Reichert, J. C., Udem, T., Hänsch, T. W., von Zanthier, J., WALTHER, H., Schnatz, H., Riehle, F., Pokasov, P. V., et al. (2001) · Optics Communications · doi:10.1016/s0030-4018(01)01190-7 · Cited by 72
Stenger, J., Binnewies, T., Wilpers, G., Riehle, F., Telle, H. R., Ranka, J. K., Windeler, R. S., & Stentz, A. J. (2001) · Physical Review A · doi:10.1103/physreva.63.021802 · Cited by 68
Metrological properties of optical frequency standard
Acef, O. (1997) · Optics Communications · doi:10.1016/s0030-4018(96)00566-4 · Cited by 59
Picard, S., Robertsson, L., Ma, L.-S., Nyholm, K., Merimaa, M., Ahola, T., Balling, P., Křen, P., & Wallerand, J. (2003) · Applied Optics · doi:10.1364/ao.42.001019 · Cited by 51
Application of general relativity to metrology
Guinot, B. R. (1997) · Metrologia · doi:10.1088/0026-1394/34/3/9 · Cited by 42
Subkilohertz absolute-frequency measurement of the 467-nm electric octupole transition in171Yb+
Blythe, P. J., Webster, S. A., Margolis, H. S., Lea, S. N., Huang, G., Choi, S.-K., Rowley, W. R. C., Gill, P., & Windeler, R. S. (2003) · Physical Review A · doi:10.1103/physreva.67.020501 · Cited by 38
Vogel, K. R., Diddams, S. A., Oates, C. W., Curtis, E. A., Rafac, R. J., Itano, W. M., Bergquist, J., Fox, R. W., Lee, W. D., Wells, J. S., et al. (2001) · Optics Letters · doi:10.1364/ol.26.000102 · Cited by 37
Chardonnet, C., & Bordé, C. J. (1994) · Journal of Molecular Spectroscopy · doi:10.1006/jmsp.1994.1219 · Cited by 30
A 633 nm iodine-stabilized diode-laser frequency standard
Edwards, C. S., Barwood, G. P., Gill, P. R., & Rowley, W. R. C. (1999) · Metrologia · doi:10.1088/0026-1394/36/1/7 · Cited by 22
Hong, F.-L., Zhang, Y., Ishikawa, J., Onae, A., & Matsumoto, H. (2002) · Journal of the Optical Society of America B · doi:10.1364/josab.19.000946 · Cited by 21
Cited by
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb
Diddams, S. A., Hollberg, L., & Mbele, V. (2007) · Nature · doi:10.1038/nature05524 · Cited by 805
CODATA recommended values of the fundamental physical constants: 2002
Mohr, P. J., & Taylor, B. N. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.1 · Cited by 654
Compact, stable and efficient all-fibre gas cells using hollow-core photonic crystal fibres
Benabid, F., Couny, F., Knight, J. C., Birks, T. A., & Russell, P. S. J. (2005) · Nature · doi:10.1038/nature03349 · Cited by 506
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Metadata
- Authors
- Quinn, T. J.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2003-04
- Volume
- 40
- Issue
- 2
- Pages
- 103-133
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2146358041
- Cited by
- 409
- References
- 30
- FWCI
- 42.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.