Phase variations in microwave cavities for atomic clocks
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We analyse the phase variations of the microwave field in a TE 011 microwave cavity and how these variations affect the frequency of an atomic clock. We analytically solve for the microwave fields in a TE 011 cavity. These analytic solutions show significant new terms that are not present in previous two-dimensional treatments. The new terms show that cavities with small radii, near 2.1 cm for a 9.2 GHz cavity, have smaller phase shifts than cavities with larger radii. We also show that the three-dimensional phase variations near the axis of the cavity can be efficiently calculated with a rapidly converging series of two-dimensional finite element calculations. The cavities used in atomic clocks have holes in the endcaps, and we use finite element methods to study the large fields and phase shifts near these holes. The effects of the phase variations on atoms traversing a cavity are analysed using the sensitivity function, and we present a cavity design that has small phase shifts for all atomic trajectories. For two π/2 pulses, the proposed cavity has transverse variations of the effective phase that are within ±0.1 µrad and produce no systematic frequency error for a nearly homogeneous and expanding cloud of atoms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298 · cited 1×
“In the current generation of laser-cooled atomic fountain clocks, accuracies have advanced to near and beyond 10−15 [1].”
Background
Cited by
Wynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationFirst accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Optical lattice clock with atoms confined in a shallow trap
Lemonde, P., & Wolf, P. (2005) · Physical Review A · doi:10.1103/physreva.72.033409 · Cited by 114
Metadata
- Authors
- Li, R., & Gibble, K.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2004-10-05
- Volume
- 41
- Issue
- 6
- Pages
- 376-386
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2122084668
- Cited by
- 66
- References
- 1
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phase variations in microwave cavities for atomic clocks. https://app.cochat.ai/papers/10.1088/0026-1394/41/6/004
- The paper
- Li, R., & Gibble, K. (2004). Phase variations in microwave cavities for atomic clocks. Metrologia. https://doi.org/10.1088/0026-1394/41/6/004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.