We report on the implementation and the metrological characterization of a vapor-cell Rb frequency standard working in pulsed regime. The three main parts that compose the clock, physics package, optics and electronics, are described in detail in the paper. The prototype is designed and optimized to detect the clock transition in the optical domain. Specifically, the reference atomic transition, excited with a Ramsey scheme, is detected by observing the interference pattern on a laser absorption signal. \ The metrological analysis includes the observation and characterization of the clock signal and the measurement of frequency stability and drift. In terms of Allan deviation, the measured frequency stability results as low as $1.7\times 10^{-13} \ τ^{-1/2}$, $τ$ being the averaging time, and reaches the value of few units of $10^{-15}$ for $τ=10^{4}$ s, an unprecedent achievement for a vapor cell clock. We discuss in the paper the physical effects leading to this result with particular care to laser and microwave noises transferred to the clock signal. The frequency drift, probably related to the temperature, stays below $10^{-14}$ per day, and no evidence of flicker floor is observed. \ We also mention some possible improvements that in principle would lead to a clock stability below the $10^{-13}$ level at 1 s and to a drift of few units of $10^{-15}$ per day.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Quantum Physics of Atomic Frequency Standards
Vanier, J., & Audoin, C. (1989) · Institute of Physics eBooks · doi:10.1887/085274434x · Cited by 624
The Quantum Physics of Atomic Frequency Standards: Recent Developments
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 553
Santarelli, G., Audoin, C., Makdissi, A., Laurent, P., Dick, G. J., & Clairon, A. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710548 · Cited by 314
Vanier, J., Kunski, R., Cyr, N., Savard, J.-Y., & Têtu, M. (1982) · Journal of Applied Physics · doi:10.1063/1.331467 · Cited by 123
High-stability compact atomic clock based on isotropic laser cooling
Esnault, F.-X., Holleville, D., Rossetto, N., Guérandel, S., & Dimarcq, N. (2010) · Physical Review A · doi:10.1103/physreva.82.033436 · Cited by 85
Light-shift suppression in laser optically pumped vapour-cell atomic frequency standards
Affolderbach, C., Andreeva, C., Cartaleva, S., Karaulanov, T. S., Mileti, G., & Slavov, D. G. (2005) · Applied Physics B · doi:10.1007/s00340-005-1804-7 · Cited by 63
Pulsed optically pumped Rb87 vapor cell frequency standard: A multilevel approach
Micalizio, S., Godone, A., Levi, F., & Calosso, C. E. (2009) · Physical Review A · doi:10.1103/physreva.79.013403 · Cited by 50
Self-citationElectronics for the Pulsed Rubidium Clock: Design and Characterization
Calosso, C. E., Micalizio, S., Godone, A., Bertacco, E. K., & Levi, F. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.458 · Cited by 34
Self-citationLight shift of coherent population trapping resonances
Nagel, A., Brandt, S., Meschede, D., & Wynands, R. (1999) · Europhysics Letters (EPL) · doi:10.1209/epl/i1999-00494-8 · Cited by 33
Pulsed optically pumped rubidium clock with high frequency-stability performance
Micalizio, S., Godone, A., Calosso, C. E., Levi, F., Affolderbach, C., & Gruet, F. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2215 · Cited by 30
Self-citation
Cited by
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Compact Optical Atomic Clock Based on a Two-Photon Transition in Rubidium
Martin, K. W., Phelps, G., Lemke, N. D., Bigelow, M. S., Stuhl, B., Wojcik, M., Holt, M., Coddington, I., Bishop, M. W., & Burke, J. H. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.9.014019 · Cited by 169
Metadata
- Authors
- Micalizio, S., Calosso, C. E., Godone, A., & Levi, F.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2012-05-16
- Volume
- 49
- Issue
- 4
- Pages
- 425-436
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2019818641
- Cited by
- 177
- References
- 10
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.