The DOI matches its Crossref record.
Acoustic gas thermometry
Open accessAbstract
We review the principles, techniques and results from primary acoustic gas thermometry (AGT). Since the establishment of ITS-90, the International Temperature Scale of 1990, spherical and quasi-spherical cavity resonators have been used to realize primary AGT in the temperature range 7 K to 552 K. Throughout the sub-range 90 K < T < 384 K, at least two laboratories measured ( T − T 90 ). (Here T is the thermodynamic temperature and T 90 is the temperature on ITS-90.) With a minor exception, the resulting values of ( T − T 90 ) are mutually consistent within 3 × 10 −6 T . These consistent measurements were obtained using helium and argon as thermometric gases inside cavities that had radii ranging from 40 mm to 90 mm and that had walls made of copper or aluminium or stainless steel. The AGT values of ( T − T 90 ) fall on a smooth curve that is outside ± u ( T 90 ), the estimated uncertainty of T 90 . Thus, the AGT results imply that ITS-90 has errors that could be reduced in a future temperature scale. Recently developed techniques imply that low-uncertainty AGT can be realized at temperatures up to 1350 K or higher and also at temperatures in the liquid-helium range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
First accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Perspectives for a new realization of the pascal by optical methods
Jousten, K., Hendricks, J., Barker, D., Douglas, K., Eckel, S., Egan, P., Fedchak, J., Flügge, J., Gaiser, C., Olson, D., et al. (2017) · Metrologia · doi:10.1088/1681-7575/aa8a4d · Cited by 123
Li, Y., Shi, C., Liu, J., Liu, E., Shao, J., Chen, Z., Dorantes-Gonzalez, D. J., & Hu, X. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/1/015006 · Cited by 41
Xing, C., Folsom, C., Jensen, C., Ban, H., & Marshall, D. W. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/5/055602 · Cited by 9
Metadata
- Authors
- Moldover, M. R., Gavioso, R. M., Mehl, J. B., Pitre, L., de Podesta, M., & Zhang, J. T.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2014-01-16
- Volume
- 51
- Issue
- 1
- Pages
- R1-R19
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2148138963
- Cited by
- 247
- References
- 0
- FWCI
- 31.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acoustic gas thermometry. https://app.cochat.ai/papers/10.1088/0026-1394/51/1/r1
- The paper
- Moldover, M. R., Gavioso, R. M., Mehl, J. B., Pitre, L., de Podesta, M., & Zhang, J. T. (2014). Acoustic gas thermometry. Metrologia. https://doi.org/10.1088/0026-1394/51/1/r1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.