Acoustic gas thermometry
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
We review the principles, techniques and results from primary acoustic gas thermometry (AGT). Since the establishment of ITS-90, the International Temperature Scale of 1990, spherical and quasi-spherical cavity resonators have been used to realize primary AGT in the temperature range 7 K to 552 K. Throughout the sub-range 90 K < T < 384 K, at least two laboratories measured ( T − T 90 ). (Here T is the thermodynamic temperature and T 90 is the temperature on ITS-90.) With a minor exception, the resulting values of ( T − T 90 ) are mutually consistent within 3 × 10 −6 T . These consistent measurements were obtained using helium and argon as thermometric gases inside cavities that had radii ranging from 40 mm to 90 mm and that had walls made of copper or aluminium or stainless steel. The AGT values of ( T − T 90 ) fall on a smooth curve that is outside ± u ( T 90 ), the estimated uncertainty of T 90 . Thus, the AGT results imply that ITS-90 has errors that could be reduced in a future temperature scale. Recently developed techniques imply that low-uncertainty AGT can be realized at temperatures up to 1350 K or higher and also at temperatures in the liquid-helium range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cencek, W., Przybytek, M., Komasa, J., Mehl, J. B., Jeziorski, B., & Szalewicz, K. (2012) · The Journal of Chemical Physics · doi:10.1063/1.4712218 · Cited by 286 · cited 5×
“In the range 200 T/K 400, the accurate values of ηAr can be determined by combining the viscosity of helium ηHe calculated by Cencek et al (2012) with the measurements of the zero-density ratio ηAr/ηHe ≡ (viscosity of argon)/(viscosity of helium) by May et al (2007) or, very recently, by Zhang…”
MethodInfluentialSelf-citationDIAMAGNETIC SUSCEPTIBILITIES OF SIMPLE HYDROCARBONS AND VOLATILE HYDRIDES
Barter, C., Meisenheimer, R. G., & Stevenson, D. P. (1960) · The Journal of Physical Chemistry · doi:10.1021/j100838a045 · Cited by 230
Physical Acoustics and Metrology of Fluids
Trusler, M. (2020) · CRC Press eBooks · doi:10.1201/9781003062851 · Cited by 208
Argon pair potential at basis set and excitation limits
Patkowski, K., & Szalewicz, K. (2010) · The Journal of Chemical Physics · doi:10.1063/1.3478513 · Cited by 184
Gas-filled spherical resonators: Theory and experiment
Moldover, M. R., Mehl, J. B., & Greenspan, M. (1986) · The Journal of the Acoustical Society of America · doi:10.1121/1.393566 · Cited by 182 · cited 2×
“…gas (and sound) into and out of a cavity (Mehl et al 2004, Gillis et al 2009), holes drilled through the shell (a short duct terminated by a large volume) (Moldover et al 1986), acoustic transducers (Guianvarc’h et al 2009), and slits that might surround a transducer or a cable (Mehl et al 2004).”
BackgroundMethodSelf-citationVogel, E., Jäger, B., Hellmann, R., & Bich, E. (2010) · Molecular Physics · doi:10.1080/00268976.2010.507557 · Cited by 167 · cited 1×
“Lin et al (2010) used a PZT transducer to generate sound; when it was driven with RMS voltages VPZT up to 7 V, it dissipated the power (P/µW) = 5×10−3(f/kHz)1.83(VPZT/V)2.”
MethodInfluentialNew high-precision measurements of the isotopic composition of atmospheric argon
Mark, D. F., Stuart, F. M., & de Podesta, M. (2011) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2011.09.042 · Cited by 166
Acoustic thermometry: new results from 273 K to 77 K and progress towards 4 K
Pitre, L., Moldover, M. R., & Tew, W. L. (2006) · Metrologia · doi:10.1088/0026-1394/43/1/020 · Cited by 152 · cited 11×
“Second, Pitre et al (2006) reported that the acoustic resonances had large excess half-widths g ≡ gmeas − gcalc when their cavity was filled with either helium at 4 K or argon at 95 K at ‘high’ gas densities.”
BackgroundMethodInfluentialSelf-citationPresent Estimates of the Differences Between Thermodynamic Temperatures and the ITS-90
Fischer, J., de Podesta, M., Hill, K., Moldover, M. R., Pitre, L., Rusby, R. L., Steur, P. P. M., Tamura, O., White, D. R., & Wolber, L. (2011) · International Journal of Thermophysics · doi:10.1007/s10765-011-0922-1 · Cited by 141
Self-citationRadiative Corrections to the Polarizability of Helium
Łach, G., Jeziorski, B., & Szalewicz, K. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.233001 · Cited by 138
Ab initio virial equation of state for argon using a new nonadditive three-body potential
Jäger, B., Hellmann, R., Bich, E., & Vogel, E. (2011) · The Journal of Chemical Physics · doi:10.1063/1.3627151 · Cited by 118 · cited 2×
“Using a non-additive potential, Jäger et al (2011) calculated C(T ) for argon and Jäger (2013) calculated higher virial coefficients.”
MethodInfluentialBich, E., Hellmann, R., & Vogel, E. (2008) · Molecular Physics · doi:10.1080/00268970801964207 · Cited by 115
Dielectric Permittivity of Eight Gases Measured with Cross Capacitors
Schmidt, J. W., & Moldover, M. R. (2003) · International Journal of Thermophysics · doi:10.1023/a:1022963720063 · Cited by 113
Self-citationReference Viscosities of H2, CH4, Ar, and Xe at Low Densities
May, E. F., Berg, R. F., & Moldover, M. R. (2007) · International Journal of Thermophysics · doi:10.1007/s10765-007-0198-7 · Cited by 108
Self-citationAcoustic measurements of the thermodynamic temperature between the triple point of mercury and 380 K
Benedetto, G., Gavioso, R. M., Spagnolo, R., et al. (2004) · Metrologia · doi:10.1088/0026-1394/41/1/011 · Cited by 98 · cited 4×
“(Benedetto et al (2004) published a compact list of the corrections for a spherical cavity; in online supplement A (stacks.iop.org/Met/51/R1/mmedia), we reproduce this list after making minor additions and corrections.”
BackgroundResultInfluentialSelf-citationCzarnecki, A., Jeżabek, M., & Kühn, J. H. (1995) · Physics Letters B · doi:10.1016/0370-2693(94)01681-2 · Cited by 83
Improved first-principles calculation of the third virial coefficient of helium
Garberoglio, G., Moldover, M. R., & Harvey, A. H. (2011) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.116.016 · Cited by 82 · cited 2×
“…values of the second density and acoustic virial coefficients [B(T ) and βa(T ) ≡ (M/γ0)(∂u2/∂p)T] were calculated by Cencek et al (2012) and accurate values of the third density and acoustic virial coefficients [C(T ) and γa(T ) ≡ (M/2γ0)(∂2u2/∂p2)T] were calculated by Garberoglio et al (2011).”
MethodSelf-citationMay, E. F., Pitre, L., Mehl, J. B., Moldover, M. R., & Schmidt, J. W. (2004) · Review of Scientific Instruments · doi:10.1063/1.1791831 · Cited by 81
Self-citationRizzo, A., Hättig, C., Fernández, B., & Koch, H. (2002) · The Journal of Chemical Physics · doi:10.1063/1.1491402 · Cited by 70
Three-Body Nonadditive Potential for Argon with Estimated Uncertainties and Third Virial Coefficient
Cencek, W., Garberoglio, G., Harvey, A. H., McLinden, M. O., & Szalewicz, K. (2013) · The Journal of Physical Chemistry A · doi:10.1021/jp4018579 · Cited by 70 · cited 1×
“Independently, Cencek et al (2013) calculated C(T ) and estimated its uncertainty u(C).”
BackgroundGammon, B. E. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432508 · Cited by 70 · cited 1×
“Measurements in the range from 1.2 K to 423 K achieved standard uncertainties of 10−4 T to 5×10−4 T (Plumb and Cataland 1966, Grimsrud and Werntz 1967, Gammon 1976).”
BackgroundInfluentialSpherical acoustic resonator: Effects of shell motion
Mehl, J. B. (1985) · The Journal of the Acoustical Society of America · doi:10.1121/1.392448 · Cited by 67
Self-citationDesigning quasi-spherical resonators for acoustic thermometry
Mehl, J. B., Moldover, M. R., & Pitre, L. (2004) · Metrologia · doi:10.1088/0026-1394/41/4/011 · Cited by 66
Self-citationGavioso, R. M., Benedetto, G., Albo, P. A. G., Ripa, D. M., Merlone, A., Guianvarc'H, C., Moro, F., & Cuccaro, R. (2010) · Metrologia · doi:10.1088/0026-1394/47/4/005 · Cited by 64
Self-citationProgress Toward Redetermining the Boltzmann Constant with a Fixed-Path-Length Cylindrical Resonator
Zhang, J. T., Lin, H., Feng, X. J., Sun, J., Gillis, K. A., Moldover, M. R., & Duan, Y. (2011) · International Journal of Thermophysics · doi:10.1007/s10765-011-1001-3 · Cited by 62 · cited 9×
“Thus, a measurement of the average length of the cavity was sufficient for accurate AGT and it was accomplished using two-colour optical interferometry (Zhang et al 2011).”
BackgroundMethodInfluentialSelf-citationValkiers, S., Vendelbo, D., Berglund, M., & de Podesta, M. (2010) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.01.004 · Cited by 60 · cited 3×
“The results for B(T ) are consistent with the best available measurements and also with independent calculations of B(T ) made by Vogel et al (2010) using a different potential.”
MethodResultInfluential(1987) · Cited by 60
Primary acoustic thermometry between= 90 K and= 300 K
Ewing, M. B., & Trusler, J. P. M. (2000) · The Journal of Chemical Thermodynamics · doi:10.1006/jcht.1999.0606 · Cited by 48 · cited 2×
“Since 1999, relative AGT has been conducted in the wide temperature range 7 K to 552 K (Moldover et al 1999, Ewing and Trusler 2000, Benedetto et al 2004, Pitre et al 2006, Ripple et al 2007).”
BackgroundMethodCollision-induced dipole polarizability of helium dimer from explicitly correlated calculations
Cencek, W., Komasa, J., & Szalewicz, K. (2011) · The Journal of Chemical Physics · doi:10.1063/1.3603968 · Cited by 38 · cited 1×
“Their tabulated values of Bε(T ) vary from −0.0016 cm6 mol−2 at 3.799 K to −0.0651 cm6 mol−2 at 407.6 K. (See Cencek et al (2011) for classical values of bε(T ) and their uncertainty between 77 K and 322 K.) For argon, the values of Aε and bε in table 1 were determined by Schmidt and Moldover…”
MethodInfluentialFactors affecting the reproducibility of the accommodation coefficient of the spinning rotor gauge
Chang, R. F., & Abbott, P. J. (2007) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.2790910 · Cited by 15
Shell Perturbations of an Acoustic Thermometer Determined from Speed of Sound in Gas Mixtures
Gavioso, R. M., Ripa, D. M., Guianvarc'H, C., Benedetto, G., Albo, P. A. G., Cuccaro, R., Pitre, L., & Truong, D. (2010) · International Journal of Thermophysics · doi:10.1007/s10765-010-0831-8 · Cited by 14
Self-citationPyknometric volume measurement of a quasispherical resonator
Underwood, R., Davidson, S., Perkin, M., Morantz, P., Sutton, G. J. M., & de Podesta, M. (2012) · Metrologia · doi:10.1088/0026-1394/49/3/245 · Cited by 9 · cited 2×
“In one remarkable example, the fractional difference between a microwave volume determination and a weighing volume determination was (0.46 ± 1.81) × 10−6 (Underwood et al 2012).”
BackgroundInfluentialAssessment of Uncertainty in the Determination of the Boltzmann Constant by an Acoustic Technique
de Podesta, M., Sutton, G. J. M., Underwood, R., Perkin, M., Davidson, S., & Morantz, P. (2010) · International Journal of Thermophysics · doi:10.1007/s10765-010-0897-3 · Cited by 8
Cited by
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
CODATA Recommended Values of the Fundamental Physical Constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.4954402 · Cited by 252
First accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Perspectives for a new realization of the pascal by optical methods
Jousten, K., Hendricks, J., Barker, D., Douglas, K., Eckel, S., Egan, P., Fedchak, J., Flügge, J., Gaiser, C., Olson, D., et al. (2017) · Metrologia · doi:10.1088/1681-7575/aa8a4d · Cited by 123
Li, Y., Shi, C., Liu, J., Liu, E., Shao, J., Chen, Z., Dorantes-Gonzalez, D. J., & Hu, X. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/1/015006 · Cited by 41
Metadata
- Authors
- Moldover, M. R., Gavioso, R. M., Mehl, J. B., Pitre, L., de Podesta, M., & Zhang, J. T.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2014-01-16
- Volume
- 51
- Issue
- 1
- Pages
- R1-R19
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2148138963
- Cited by
- 247
- References
- 33
- FWCI
- 31.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.