Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 19 of the 21 references it cites were found in a registry or an index; 5 of the 11 sources its claims cite were checked for support.

Relativistic corrections for time and frequency transfer in optical fibres

Open access
Geršl, J, Delva, P, Wolf, P · 2015 · Metrologia

Abstract

We derive relativistic corrections for one-way and two-way time and frequency transfer over optical fibres neglecting no terms that exceed 1 ps in time and 10 −18 in fractional frequency, and estimate their magnitude in typical fibre links. We also provide estimates of the uncertainties in the evaluation of the relativistic corrections due to imperfect knowledge of parameters like the coordinates of the fibre and stations, Earth rotation, or thermal effects of the fibre index and length. The links between Teddington(UK) and Paris(F) as well as Braunschweig(D) and Paris(F), that are currently under construction, are studied as specific examples.

Overview

CoChat Summary

TL;DR

The paper derives relativistic corrections for one-way and two-way time and frequency transfer in optical fibres, keeping all terms larger than 1 ps in time and 10^-18 in fractional frequency. It then estimates the size and uncertainty of these corrections for typical links and applies the formulas to the NPL–SYRTE and PTB–SYRTE fibre links.

Key findings

  • For a 1000 km fibre with refractive index 1.5, the main one-way time-transfer terms are estimated as 5 ms (Newtonian, c^-1), ±5 ns (Sagnac, c^-2), and 3 ps (c^-3 Shapiro-related term); higher-order terms are said to be negligible for 1 ps accuracy.
  • For two-way time transfer on real links, the computed Sagnac corrections are 3976 ± 27 ps for PTB–SYRTE (1401 km) and 1214 ± 6 ps for NPL–SYRTE (813 km); the uncertainty from poorly known fibre path is estimated from a 53 ps spread for PTB–SYRTE paths and 12 ps for NPL–SYRTE paths.
  • For one-way frequency transfer, the paper estimates a c^-1 term of about 2 × 10^-13 for a 1000 km fibre with n = 1.5 when temperature-driven refractive-index change is used as the example.
  • For two-way frequency transfer, the paper reports that the largest fibre-process contributions are below 10^-18, with example magnitudes of 8 × 10^-20 (Coriolis from Earth tides), 4 × 10^-20 (Euler term), and 3 × 10^-20 (Earth-tide acceleration) per 1000 km.

Methods

  • The paper develops a relativistic model of signal propagation in a moving optical fibre using the Geocentric Celestial Reference System (GCRS), deriving propagation equations and expanding them up to order c^-3 for time transfer and c^-2 for frequency transfer.
  • It evaluates required input-parameter uncertainties for 1 ps time-transfer accuracy and 10^-18 frequency-transfer accuracy, including fibre length, refractive index, fibre position, fibre velocity/acceleration, Earth rotation, and thermal effects.
  • It computes numerical corrections for two European fibre links (NPL–SYRTE and PTB–SYRTE) using discretized fibre routes built from measured shelter positions and fibre lengths, with direct, maximum, and minimum path scenarios.

Limitations

  • The paper states that the fibre path between PTB–SYRTE and NPL–SYRTE is “poorly known,” so the uncertainty of the computed Sagnac correction is limited by incomplete route knowledge.
  • The authors state that the gravitational-plus-centrifugal endpoint terms in frequency transfer are not treated in detail here and are “a subject of a separate research.”
  • Evident from the text: several derivations rely on approximations and neglected higher-order terms; the paper explicitly says formulas are kept only to the level needed for 1 ps or 10^-18 accuracy, so effects below those thresholds are not modeled in detail.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1088/0026-1394/52/4/552

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

5 Valid · 8 Not valid · 8 Not checked · 96 Own results and interpretations

61 more claims

Create a free account to see all 117 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 25
  • It may state two separate claims as one. 29
  • The quote only partly states this claim. 7

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 21 references

Cited by

See all 40

Metadata

Authors
Geršl, J., Delva, P., & Wolf, P.
Affiliations
  • Český metrologický institut (CZ)
  • Systèmes de Référence Temps-Espace (FR)
Corresponding author
Geršl, J
Venue
Metrologia
Published
2015-07-16
Volume
52
Issue
4
Pages
552-564
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W2762679738
Cited by
40
References
21
Citations by year
2026: 1 · 2023: 2 · 2022: 4 · 2021: 2 · 2020: 3 · 2019: 6 · 2018: 6 · 2017: 9 · 2016: 5 · 2015: 2
FWCI
3.54
Type
journal article
Language
en
Open access
Licence
Locations
  • Metrologia (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • HAL (submittedVersion, other-oa)
  • arXiv (Cornell University)
Funders
EURAMET (SIB55 ITOC)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
  • Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
Keywords
relativistic corrections, time transfer, frequency transfer, optical fibers, Earth rotation, uncertainty estimation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relativistic corrections for time and frequency transfer in optical fibres. https://app.cochat.ai/papers/10.1088/0026-1394/52/4/552
The paper
Geršl, J., Delva, P., & Wolf, P. (2015). Relativistic corrections for time and frequency transfer in optical fibres. Metrologia. https://doi.org/10.1088/0026-1394/52/4/552

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.