The watt or Kibble balance: a technique for implementing the new SI definition of the unit of mass
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
The redefinition of the SI unit of mass in terms of a fixed value of the Planck constant has been made possible by the Kibble balance, previously known as the watt balance. Once the new definition has been adopted, the Kibble balance technique will permit the realisation of the mass unit over a range from milligrams to kilograms. We describe the theory underlying the Kibble balance and practical techniques required to construct such an instrument to relate a macroscopic physical mass to the Planck constant with an uncertainty, which is achievable at present, in the region of 2 parts in 10 8 . A number of Kibble balances have either been built or are under construction and we compare the principal features of these balances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Klitzing, K. V., Dorda, G., & Pepper, M. (1980) · Physical Review Letters · doi:10.1103/physrevlett.45.494 · Cited by 7,119
Possible new effects in superconductive tunnelling
Josephson, B. D. (1962) · Physics Letters · doi:10.1016/0031-9163(62)91369-0 · Cited by 4,130 · cited 2×
“The Josephson effect [7] allows the construction of extremely precise voltage references by illuminating weak links between superconductors with microwave radiation of frequency f.”
BackgroundCODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441 · cited 2×
“The horizontal scale is large making it difficult to compare the most precise measurements with each other and the recommended value by the Task Group on Fundamental Physical Constants under the auspices of the Committee on Data for Science and Technology (CODATA) [142].”
MethodA new generation of absolute gravimeters
Niebauer, T. M., Sasagawa, G. S., Faller, J. E., Hilt, R. L., & Klopping, F. J. (1995) · Metrologia · doi:10.1088/0026-1394/32/3/004 · Cited by 604 · cited 1×
“The dropped mass can be either macroscopic [90] or atomic [91, 92].”
BackgroundRecent advances in displacement measuring interferometry
Bobroff, N. (1993) · Measurement Science and Technology · doi:10.1088/0957-0233/4/9/001 · Cited by 430
Melchior, P. J. (1978) · CERN Document Server (European Organization for Nuclear Research) · Cited by 428
Halbach permanent magnet machines andapplications: a review
Zhu, Z. Q., & Howe, D. (2001) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20010479 · Cited by 420 · cited 1×
“Halbach arrays [38] are an alternative to using a yoke to achieve a magnetic field in a confined region of space and mitigate the disadvantage of having to introduce a magn etically non-linear material.”
MethodAtomic Masses and Fundamental Constants 5
(1976) · Springer eBooks · doi:10.1007/978-1-4684-2682-3 · Cited by 390
CODATA Recommended Values of the Fundamental Physical Constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Journal of Physical and Chemical Reference Data · doi:10.1063/5.0064853 · Cited by 299
A Measurement of the Gyromagnetic Ratio of the Proton by the Strong Field Method
Kibble, B. P. (1976) · Atomic Masses and Fundamental Constants 5 · doi:10.1007/978-1-4684-2682-3_80 · Cited by 263 · cited 2×
“Previously known as the moving-coil watt balance, the moving coil Kibble balance was invented at the National Physical Laboratory (NPL) by Bryan Kibble [1] in 1975 and it relates virtual mechanical and electrical power.”
MethodA New Theorem in Electrostatics and its Application to Calculable Standards of Capacitance
THOMPSON, A. M., & LAMPARD, D. G. (1956) · Nature · doi:10.1038/177888a0 · Cited by 257 · cited 1×
“When combined with an SI ohm derived from the calculable capacitor [4], the Kibble balance can be used to realise the SI volt or SI ampere [5].”
MethodHistory and progress on accurate measurements of the Planck constant
Steiner, R. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/1/016101 · Cited by 237
New International Electrical Reference Standards Based on the Josephson and Quantum Hall Effects
Taylor, B. N., & Witt, T. J. (1989) · Metrologia · doi:10.1088/0026-1394/26/1/004 · Cited by 233 · cited 1×
“The discovery of the quantum Hall effect (QHE) by von Kitzing in 1980 [6], in conjunction with the previously discovered Josephson effect [7], led to the provision of highly stable representations of the ohm and volt, respectively [8].”
BackgroundRedefinition of the kilogram: a decision whose time has come
Mills, I. M., Mohr, P. J., Quinn, T. J., Taylor, B. N., & Williams, E. R. (2005) · Metrologia · doi:10.1088/0026-1394/42/2/001 · Cited by 227 · cited 1×
“This enabled the Kibble balance to relate macroscopic mass to h with sufficiently low uncertainty to contemplate redefining the kilogram [10].”
MethodMise en Pratique of the Definition of the Metre (1992)
Quinn, T. J. (1994) · Metrologia · doi:10.1088/0026-1394/30/5/011 · Cited by 224 · cited 1×
“Such iodine-stabilised lasers can produce almost monochromatic radiation with frequency stabilities far better than 1 part in 109 and, as many of the lines are well characterised and recommended for the practical realisation of the metre [72], such a laser can act as a primary standard of length.”
BackgroundA Precise Low Temperature dc Ratio Transformer
Harvey, I. K. (1972) · Review of Scientific Instruments · doi:10.1063/1.1685508 · Cited by 215 · cited 1×
“The Hall resistance of the quantised Hall sample is compared to that of the Kibble balance resistor using a cryogenic current comparator [68, 69].”
MethodStability comparison of two absolute gravimeters: optical versus atomic interferometers
Gillot, P., Francis, O., Landragin, A., Pereira Dos Santos, F., & Merlet, S. (2014) · Metrologia · doi:10.1088/0026-1394/51/5/l15 · Cited by 201
A Clock Directly Linking Time to a Particle's Mass
Lan, S.-Y., Kuan, P.-C., Estey, B., English, D., Brown, J. M., Hohensee, M., & Müller, H. (2013) · Science · doi:10.1126/science.1230767 · Cited by 155 · cited 1×
“The true power of fixing h in the new SI is that it enables a range of techniques to realise SI mass from Kibble balances and x-ray crystal density techniques [161] at the macroscopic level to Compton clocks [162] at the atomic scale.”
BackgroundComparison between two mobile absolute gravimeters: optical versus atomic interferometers
Merlet, S., Bodart, Q., Malossi, N., Landragin, A., Santos, F. P. D., Gitlein, O., & Timmen, L. (2010) · Metrologia · doi:10.1088/0026-1394/47/4/l01 · Cited by 149
Robinson, I. A. (2011) · Metrologia · doi:10.1088/0026-1394/49/1/016 · Cited by 140 · cited 10×
“This is a necessary, but not sufficient, test for the accuracy of the apparatus because offsets which are proportional to the quantity being changed will not be detected [48].”
BackgroundMethodInfluentialSelf-citationAn initial measurement of Planck's constant using the NPL Mark II watt balance
Robinson, I. A., & Kibble, B. P. (2007) · Metrologia · doi:10.1088/0026-1394/44/6/001 · Cited by 136 · cited 22×
“At four laboratories (METAS, NPL, NIM, and NIST), more than one balance have been built.”
BackgroundInfluentialSelf-citationJiang, Z., Pálinkáš, V, Arias, F. E., Liard, J., Merlet, S., Wilmes, H., Vitushkin, L., Robertsson, L., Tisserand, L., Pereira Dos Santos, F., et al. (2012) · Metrologia · doi:10.1088/0026-1394/49/6/666 · Cited by 113 · cited 1×
“This makes it desirable to verify the operation of the instrument and this is usually achieved by comparison with other similar instruments in gravimeter comparisons [103, 104].”
ResultSelf-citationA determination of Planck's constant using the NRC watt balance
Sánchez, C. A., Wood, B., Green, R. G., Liard, J. O., & Inglis, D. (2014) · Metrologia · doi:10.1088/0026-1394/51/2/s5 · Cited by 99 · cited 3×
“Many parts of the system can be verified by setting carefully chosen parameters to values outside their usual range and by checking that the effect of the change is as expected [14, 70].”
BackgroundMethodDevelopment and metrological applications of Josephson arrays at PTB
Behr, R., Kieler, O., Kohlmann, J., Müller, F., & Palafox, L. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/12/124002 · Cited by 98
Invited Article: A precise instrument to determine the Planck constant, and the future kilogram
Haddad, D., Seifert, F. C., Chao, L., Li, S., Newell, D. B., Pratt, J. R., Williams, C. J., & Schlamminger, S. (2016) · Review of Scientific Instruments · doi:10.1063/1.4953825 · Cited by 94 · cited 3×
“626 069 83 34 148 2016 [81] Permanent magnet, ongoing.”
BackgroundSelf-citationAdapting the International System of Units to the twenty-first century
Mills, I. M., Mohr, P. J., Quinn, T., Taylor, B. N., & Williams, E. R. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0180 · Cited by 84 · cited 1×
“The existing proposals to revise the SI in 2018 would fix the values of h and the elementary charge e which would also fix the values of KJ and RK, within the SI, eliminating the need for KJ 90 − and RK 90 − [12].”
BackgroundAn introduction to frequency standards
Lewis, L. L. (1991) · Proceedings of the IEEE · doi:10.1109/5.84969 · Cited by 78 · cited 1×
“As this reference is needed at an uncertainty better than a part in 109 and the primary clocks which maintain the SI unit of time operate at levels better than parts in 1016 this is not usually a problem [85].”
BackgroundAlignment uncertainties of the NIST watt experiment
Gillespie, Fujii, K., Newell, D. B., Olsen, P. T., Picard, O. A., Steiner, R. L., Stenbakken, G. N., & Williams, E. R. (1997) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.571933 · Cited by 53 · cited 1×
“1 applies correctly, and the alignments are carried out using the techniques described below [128].”
MethodDetermining the Magnetic-Properties of 1 Kg Mass Standards
Davis, R. (1995) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.100.015 · Cited by 48 · cited 1×
“All mass standards, including platinum–iridium and stainless steel, have a finite magnetic susceptibility [122, 123] which can affect their apparent weight when in the spatially varying magnetic field of a Kibble balance.”
BackgroundFoundation for the redefinition of the kilogram
Richard, P., Fang, H., & Davis, R. (2016) · Metrologia · doi:10.1088/0026-1394/53/5/a6 · Cited by 42
Davidson, S. (2010) · Metrologia · doi:10.1088/0026-1394/47/4/015 · Cited by 35
On the gravimetric contribution to watt balance experiments
Jiang, Z., Pálinkáš, V., Francis, O., Baumann, H., Mäkinen, J., Vitushkin, L. F., Merlet, S., Tisserand, L., Jousset, P., Rothleitner, C., et al. (2013) · Metrologia · doi:10.1088/0026-1394/50/5/452 · Cited by 35 · cited 1×
“To derive the mass M from the weight Mg, which is measured by the Kibble balance, it is necessary to know the value of the acceleration due to gravity g at the centre of gravity of the mass during the weighing phase of the measurement [88, 89].”
MethodTime and frequency distribution using satellites
Levine, J. (2002) · Reports on Progress in Physics · doi:10.1088/0034-4885/65/8/201 · Cited by 34 · cited 1×
“In addition, modern GPS-disciplined oscillators, which take their long-term time reference from visible GPS satellites, can be used, provided that the oscillator which is controlled has excellent phase noise and sufficient medium term stability to work properly when few satellites are available [86, 87].”
BackgroundBridging classical and quantum mechanics
Haddad, D., Seifert, F. C., Chao, L., Li, S., Newell, D. B., Pratt, J. R., Williams, C. J., & Schlamminger, S. (2016) · Metrologia · doi:10.1088/0026-1394/53/5/a83 · Cited by 29
Self-citationA brief history of the unit of mass: continuity of successive definitions of the kilogram
Davis, R., Barat, P., & Stöck, M. (2016) · Metrologia · doi:10.1088/0026-1394/53/5/a12 · Cited by 27
Progress on accurate measurement of the Planck constant: Watt balance and counting atoms
Li, S., Zhang, Z., Zhao, W. G., Li, Z., & Huang, S. (2015) · Chinese Physics B · doi:10.1088/1674-1056/24/1/010601 · Cited by 23
Theoretical analysis for the design of the French watt balance experiment force comparator
Pinot, P., Genevès, G., Haddad, D., David, J., Juncar, P., Lecollinet, M., Macé, S., & Villar, F. (2007) · Review of Scientific Instruments · doi:10.1063/1.2789665 · Cited by 16 · cited 1×
“BIPM Mass comparator [112] KRISS Mass comparator [17] LNE Flexure balance [113] METAS Mass comparator [22] MSL Pressure balance [43] NIM Beam bal.”
MethodCryogenic Current Comparator Metrology
Gutmann, P., & Bachmair, H. (1989) · Springer eBooks · doi:10.1007/978-3-642-95592-1_10 · Cited by 9
News from the BIPM laboratories—2015
Stöck, M., Wielgosz, R. I., Arias, E. F., Arcos, J.-M. L., & Milton, M. J. T. (2016) · Metrologia · doi:10.1088/0026-1394/53/1/103 · Cited by 1
Cited by
How to tell the difference between a model and a digital twin
Wright, L., & Davidson, S. (2020) · Advanced Modeling and Simulation in Engineering Sciences · doi:10.1186/s40323-020-00147-4 · Cited by 601
“In simple terms, the Kibble balance equates electromagnetic and gravitational forces to determine mass in terms of very accurate quantum electrical standards [5].”
Background
Metadata
- Authors
- Robinson, I. A., & Schlamminger, S.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2016-09-28
- Volume
- 53
- Issue
- 5
- Pages
- A46-A74
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2526158836
- Cited by
- 240
- References
- 39
- FWCI
- 22.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.