The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index; none of the 3 sources its claims cite is checked for support yet.
Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects
Open accessAbstract
A little-known method of measuring the volume of small objects based on Archimedes' principle is described, which involves suspending an object in a water-filled container placed on electronic scales. The suspension technique is a variation on the hydrostatic weighing technique used for measuring volume. The suspension method was compared with two other traditional water displacement methods of measuring volume, i.e. placing an object in a measuring cylinder and recording the rise in the water level and immersing the object in a water-filled container with an overflow spout to record the volume of overflow. The accuracy and precision of the three methods was compared using ten accurately machined PVC cylinders ranging in volume from 1.5 to 15.7 ml. The mean difference between the actual and measured volumes was 3.3 ± 7.3%, -1.6 ± 7.2% and 0.03 ± 0.45%, for the level, overflow and suspension methods respectively. Each measurement was repeated twice to obtain the reproducibility of the three displacement techniques. The reproducibility was -1.7 ± 8.5%, 0.09 ± 3% and -0.04 ± 0.43% for the level, overflow and suspension techniques respectively. The results show that the suspension technique is more accurate and precise than the traditional water displacement methods and is more accurate than measuring volume using Vernier calliper measurements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
16 Own result · 9 Own interpretation · 2 No full text of the sources · 2 Own method · 1 Sources not found · 1 No basis given
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The reproducibility was -1.7 ± 8.5%, 0.09 ± 3% and -0.04 ± 0.43% for the level, overflow and suspension techniques respectively.”
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The mean difference between the actual and measured volumes was 3.3 ± 7.3%, -1.6 ± 7.2% and 0.03 ± 0.45%, for the level, overflow and suspension methods respectively.”
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The mean difference between the actual and measured volumes was 3.3 ± 7.3%, -1.6 ± 7.2% and 0.03 ± 0.45%, for the level, overflow and suspension methods respectively.”
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The reproducibility was -1.7 ± 8.5%, 0.09 ± 3% and -0.04 ± 0.43% for the level, overflow and suspension techniques respectively.”
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The mean difference between the actual and measured volumes was 3.3 ± 7.3%, -1.6 ± 7.2% and 0.03 ± 0.45%, for the level, overflow and suspension methods respectively.”
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- It may state two separate claims as one. 5
- Probably not a substantial claim. 6
Create a free account to see these claims.
Create a free account to see these assumptions.
15 more claims
Create a free account to see all 31 claims and every source verdict.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Abstract
“0.03 ± 0.45%, for the level, overflow and suspension methods respectively.”
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Discussion
“| Suspension 0.001 ± 0.015 | 0.01 ± 0.27 1.0 | |”
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Abstract
“The mean difference between the actual and measured volumes was 3.3 ± 7.3%, -1.6 ± 7.2% and 0.03 ± 0.45%, for the level, overflow and suspension methods respectively.”
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Discussion
“| Level | -0.14 ± 0.16 | 3.3 ± 7.1 | 0.9989 | | Overflow -0.04 ± 0.21 | -1.6 ± 7.4 | 0.999 | |”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Additional information
“a reproducibility of 0.04% for pycnometry compared with 0.015% for suspension”
§ Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects > Additional information
“A survey of the specifications of pycnometers shows that in the volume range 0-50 ml they have a typical accuracy of 0.03% and reproducibility of 0.015%.”
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Ives, K. J. (1978) · Springer eBooks · doi:10.1007/978-94-009-9938-1_8 · Cited by 463
Research works printed but not linked: 3
- Halliday D, 1997, Fundamentals of Physics
- Heath T L, 2002, The Works of Archimedes
- Kirkup L, 1994, Experimental Methods
Cited by
Items 201–276 of 276
Data Quality of Salt Property Measurements
Ebert, W. L., & Rose, M. A. (2021) · doi:10.2172/1880777 · Cited by 2
Low‐temperature thermal and physical properties of lunar meteorites
Macke, R. J., Opeil, C. P., Britt, D. T., Consolmagno, G. J., & Irving, A. J. (2024) · Meteoritics and Planetary Science · doi:10.1111/maps.14171 · Cited by 1
Aubrecht, F. J., Orme, K., Saul, A., Cai, H., Ranathunge, T. A., Silberstein, M. N., & McDonald, B. R. (2024) · Angewandte Chemie · doi:10.1002/ange.202408673 · Cited by 1
Falkner, F., Mayer, S. A., Thomas, B., et al. (2025) · Tissue Engineering Part A · doi:10.1177/19373341251372950 · Cited by 1
Water Deficit Modulates Morphophysiological and Enzymatic Changes in Paubrasilia echinata Seedlings
de Medeiros, T. K. F., de Souza, G. L. F., Bezerra, F. T. C., et al. (2026) · Ecologies · doi:10.3390/ecologies7010016 · Cited by 1
“…MD, United States of America); shoot and root length, in cm, using a millimeter ruler; root volume, in cm 3 , according to Archimedes’ principle [31] (the roots were washed to remove the substrate, dried on paper towels, and then immersed in a graduated cylinder with 50 mL of distilled water,…”
An, X., Dong, K., Cao, K., et al. (2026) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2026.03.063 · Cited by 1
Xu, G. L., Li, H., & Peng, C. (2026) · Engineering Research Express · doi:10.1088/2631-8695/ae6b01 · Cited by 1
“Sintered samples were weighed using a balance with a precision of 0.0001 g (Mettler-Toledo, Switzerland), and the bulk density and porosity of the alumina ceramics were measured using the Archimedes drainage method [21].”
InfluentialLi, Q., Zhang, T., Wang, Y. C., et al. (2026) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2026.189693 · Cited by 1
Effect of Different Dietary Protein Levels on Testosterone And Testicular Parameters in Awassi Lambs
Al-Doski, S. (2022) · The Journal of The University of Duhok · doi:10.26682/ajuod.2022.25.1.2 · Cited by 1
A Real-time Object Volume Measurement Method Based on Line Laser Scanning
Zhang, B., Cao, B., & Ma, H. (2022) · Chinese Control Conference (CCC) · doi:10.23919/ccc55666.2022.9902574 · Cited by 2
Oduma, O., Glory, O., Onyekachukwu, N., et al. (2023) · Poljoprivredna tehnika · doi:10.5937/poljteh2301028o · Cited by 1
A Technique for the Measurement of the Morphological Evolution of Marine Pebbles
Bertoni, D., Renzone, G. D., Domokos, G., et al. (2023) · IEEE International Workshop on Metrology for the Sea; Learning to Measure Sea Health Parameters (MetroSea) · doi:10.1109/metrosea58055.2023.10317284 · Cited by 1
“Empirical methods used to retrieve the volume information of shapeless objects exploit the Archimedes’ principle by immersing a pebble in a beaker and measuring the change in liquid level or weight [9].”
MethodHawkins, J., Crowley, J. D., Pelletier, M. H., et al. (2023) · American Journal of Veterinary Research · doi:10.2460/ajvr.23.07.0165 · Cited by 1
“41 The technique states that the difference in weights of an object measured in 2 mediums of known density allows the observer to calculate the density of the object and the volume.”
BackgroundMethodInfluentialYoung temperate tree species show fine root trait acclimation to differences in water availability
Jaeger, F. C., Messier, C., Beyer, F., et al. (2025) · Plant and Soil · doi:10.1007/s11104-025-08047-5 · Cited by 1
“The skeletal volume of soil in each sample was measured, applying the principle of Archimedes (Hughes 2005).”
Nadar, M. S., Al-Kandari, D., & Taaqi, M. M. (2013) · Hong Kong Journal of Occupational Therapy · doi:10.1016/j.hkjot.2013.04.001 · Cited by 1
“, 2012), electronic balance measurements (Hughes, 2005; Hughes & Lau, 2008), bioelectric impedance, and computer modelling (Karges, Mark, Stikeleather, & Worrell, 2003).”
BackgroundInjectable Aorta Tissue Paste for Vocal Fold Medialization
Burns, J. A., Botelho, J. L., Bell, J. I., et al. (2016) · Annals of Otology Rhinology & Laryngology · doi:10.1177/0003489416660114 · Cited by 1
“0 g/mL, it is also equal to the volume of the implant.(3) Data obtained using both methods were comparable and have been combined in the overall data set.”
MethodA geometric model for estimating the volume and surface area of apples
Scarmana, G., McDougall, K., & Stepanyants, Y. A. (2020) · University of Southern Queensland ePrints (University of Southern Queensland) · Cited by 1
A new liquid density measurement method based on elastic spring stretching
Kovačević, M. S., Milošević, M. M., & Cimbaljević, Ž. (2021) · Physics Education · doi:10.1088/1361-6552/abebb9 · Cited by 1
“The measuring of liquid density based on the Archimedes principle has been reported by Hughes [2, 3].”
Using pycnometry and Archimedes’ principle to measure the gross and air cavity volume of fruit
Hughes, S. W., & Olaya, S. Q. (2021) · IOP SciNotes · doi:10.1088/2633-1357/abf33f · Cited by 1
“Hughes (2005) described a quick, cheap and accuratemethod formeasuring the volume of small objects (1.5–15 cm3).”
BackgroundInfluentialSelf-citationRao, S., & Srinivasulu, S. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.03.014 · Cited by 1
Determination of density of a liquid: revisited through the lens of conditions of floating
Bhattacharya, A., Chattopadhyay, K. N., & Adhikary, C. (2022) · Physics Education · doi:10.1088/1361-6552/ac8dd3 · Cited by 1
Evaluation of tomographic 3D ultrasound in vascular disease
Rogers, S. K. (2019) · Research Explorer (The University of Manchester) · Cited by 1
McIntosh, M., González-Campos, J., Demaree, P., et al. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.01.04.474828 · Cited by 1
Accelerating Leaf Area Measurement Using a Volumetric ApproachPreprint
Haghshenas, A., & Emam, Y. (2022) · Research Square · doi:10.21203/rs.3.rs-1370314/v1 · Cited by 1
McIntosh, M., González-Campos, J., Demaree, P., et al. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4096503 · Cited by 1
An, X., Chen, J., Mu, Y., et al. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4184965 · Cited by 1
Lokmic‐Tomkins, Z. (2013) · Wiley eBooks · doi:10.1002/9781118444177.ch11
Ahmadi, O. (2015) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Lecythis pisonis Cambess (sapucaia): seed morphometric traits and germinative response
Cardoso, V. J. M., & Nakao, E. A. (2013) · Biotemas · doi:10.5007/2175-7925.2014v27n1p23
Preparation of BaCe0.9Yb0.1O3-δ asymmetrical membrane for hydrogen separation at high tempratures
Heidari, M. A., Zamanian, A., Babakhani, E. G., et al. (2011) · DOAJ (DOAJ: Directory of Open Access Journals) · doi:10.22078/jpst.2011.55
“Bulk density was calculated by using the modified Archimedes method [17,18].”
MethodEstimating depletion time for elastomeric pumps during pharmacist rounds
Bartlett, J. S., & Dirig, D. M. (2013) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp120544
Multiscale Drug Delivery System: Micelles Encapsulated in Hydrogels
Tang, M. Y. (2016) · Figshare
Matsuka, M. (2010) · Griffith Research Online · doi:10.25904/1912/196
The role of carotid artery disease in ischaemic stroke
Ball, S. (2019) · Research Explorer (The University of Manchester)
PENGUKURAN KETULENAN EMAS MENGGUNAKAN KAEDAH UJIAN TANPA MUSNAH: SUATU ULASAN PERBANDINGAN
Nor, F. M., Tamuri, A. R., Ismail, A. K., Ismail, M. E., & Amiruddin, M. H. (2021) · International Journal of Creative Future and Heritage (TENIAT) · doi:10.47252/teniat.v9i2.745
Development of a microcontroller-based instrument for measuring liquid density
Handayani, F., Wahyono, U., & Saehana, S. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2126/1/012025
(2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100405-0.16001-x
Diebold, J., Weiß, Y., Zürcher, S., et al. (2022) · Data in Brief · doi:10.1016/j.dib.2022.108679
Bending of a beam: an improvised instructional tool for the determination of density of a liquid
Bhattacharya, A., Chattopadhyay, K. N., & Adhikary, C. (2022) · Physics Education · doi:10.1088/1361-6552/ac9d1a
El-Touny, E. S. M. A. A., Youssef, A. M., El-deeb, A. M., et al. (2022) · SPORT TK-Revista EuroAmericana de Ciencias del Deporte · doi:10.6018/sportk.537591
Godfrey, J. M., Nelson, A. S., Topping, M., et al. (2023) · doi:10.22541/au.168690260.09971595/v1
Carotid Artery Diameter Correlates with Plaque Volume but not with Degree of Stenosis
Phair, A., Ghosh, J., McCollum, C. N., Smith, C. J., Bowling, F. L., & Rogers, S. (2023) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2023.08.007
Accuracy of Cone Beam Computed Tomography in Volumetric Evaluation of the Mandibular Condyle
Ezz, N., Rawdy, A. E., & El-Desouky, G. (2023) · Dental Science Updates /Dental Science Updates · doi:10.21608/dsu.2023.155611.1139
“This technique was proven to be simple, consistent and accurate in measuring the volume of a given object with homogenous density as stated by Hughes (16) in his review comparing various techniques of volume measurement.”
MethodLi, C., Zhang, Q., Ren, Y., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4801348
Singh, V., Rautela, M. S., & Singh, N. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4839559
Bibb, R., Eggbeer, D., Paterson, A., et al. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95733-5.00051-x
Rathore, J. H., Rathore, P., Rathore, B., & Rathore, B. C. (2024) · ChemRxiv · doi:10.26434/chemrxiv-2024-wxzt9
Diaphragm Design for an Electret Microphone Stethoscope
Gaudio, A., Hahn, H., West, J. E., et al. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3573907
“…of the observed offsets between the only water baseline and other materials gives a time shift δ t , and the acoustic velocity of the evaluated material can be determined via the following equation : The material volumetric mass density was also computed via the suspension technique [9], [36].”
Measuring g using buoyancy: a simple and accurate method for high-school physics lab
Aviani, I., & Erceg, N. (2025) · Physics Education · doi:10.1088/1361-6552/aded76
Reimagined microphone-free acoustic volumetry: An open, DIY platform for global phenotyping
Haghshenas, A., & Emam, Y. (2025) · Smart Agricultural Technology · doi:10.1016/j.atech.2025.101430
Wang, L., Zhang, W., & Zhang, D. (2025) · Journal of Near Infrared Spectroscopy · doi:10.1177/09670335251383691
“16 The basic density and MMC of the 111 samples (42 HAW, 37 MAW and 32 SAW) were measured, and the results are shown in Figure 2.”
Ham, M.-G., Lim, Y.-G., Im, J.-H., et al. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5699148
McIntosh, M., González-Campos, J., Demaree, P., Toro-Salamanca, O., Ipinza, R., Bustamante-Sánchez, M. A., Hasbún, R., & Nelson, C. R. (2022) · Restoration Ecology · doi:10.1111/rec.70268 · Cited by 2
“For needle density, we measured fresh needle volume using the water displacement method (Hughes 2005) and divided fresh volume by dry needle mass. Needle thickness was calculated by dividing fresh needle volume by dry needle area.”
Hughes, S., Charlton, B., Farrell, P., et al. (2026) · Physics Education · doi:10.1088/1361-6552/ae2bd5
Self-citationAdelkhani, A., & Daneshkhah, E. (2026) · Experimental Techniques · doi:10.1007/s40799-025-00852-y
“After preparing the nanocomposite discs, their density was measured using the Archimedes method [39], and the micro-hardness was evaluated using the Vickers hardness test based on the ISO-6507 standard, under a 10 N force applied for 10 s [40 ].”
Goltz, L. V., Gomes, S. P., Schimming, B. C., et al. (2026) · The Anatomical Record · doi:10.1002/ar.70131
Ham, M.-G., Lim, Y.-G., Im, J.-H., et al. (2026) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2026.128382
Borosilicate glasses : from viscoplasticity to indentation cracking ?
Bourguignon, M. (2024) · theses.fr (ABES) · doi:10.70675/f651b533zf394z41b1zabf6z42ea3088265e
Narvasa, A., Grippi, T., Torresani, E., Cortes, D. D., & Miletić, M. (2026) · Case Studies in Construction Materials · doi:10.1016/j.cscm.2026.e06142
Merlonghi, L., Baschetti, M. G., Angelis, M. G. D., et al. (2026) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2026.155981
Nardini, A., Redivo, L., Petruzzellis, F., et al. (2026) · Forest Ecology and Management · doi:10.1016/j.foreco.2026.124027
Sexual dimorphism in the canines and mandibles of the Icelandic Arctic foxPreprint
Belfiore, V., Másdóttir, A. B., & Unnsteinsdóttir, E. R. (2026) · Research Square · doi:10.21203/rs.3.rs-9898794/v1
Ma, S., Wang, L., Ma, Q., et al. (2026) · Plant and Soil · doi:10.1007/s11104-026-08739-6
“Leaf volume was measured using the water displacement method with a 10-ml graduated cylinder (accuracy of ±0.2 ml; Hughes 2005).”
InfluentialKumar, A. R., & Singh, R. B. (2026) · Materials Science and Technology · doi:10.1177/02670836261463944
de Medeiros, T. K. F., Bezerra, F. T. C., de Souza, G. L. F., et al. (2026) · International Journal of Plant Biology · doi:10.3390/ijpb17070057
“…MD, USA); shoot and root length (cm), measured with a millimeter ruler; and root volume (cm 3 ), determined according to Archimedes’ principle [31], in which roots were washed to remove substrate residues, dried with paper towels, and then immersed in a 50 mL graduated cylinder containing…”
Effect of TiO2/Y2O3 Sol Impregnation on the Properties of Silica Ceramics
Li, W., Li, H., & Huang, Y. (2026) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-026-14643-y
Roth, R., Reinke, Z., Siedlecki, M., Luitjens, J. H., Hügle, M., Enke, J. S., Liska, C., Feitelson, L.-M., Lapa, C., Kröncke, T. J., et al. (2026) · Diagnostics · doi:10.3390/diagnostics16152329
“The suspension method described by Hughes et al. [8] makes use of digital scales to accurately measure displaced water volume.”
Tricerri, N., Gamba, R., Morabito, C., et al. (2026) · Annals of Botany · doi:10.1093/aob/mcag254
ZAFIRAH, R., Wahyudi, I., Pratama, R., et al. (2026) · Journal of the Korean Wood Science and Technology · doi:10.5658/wood.2026.54.5.598
“Sample volume was determined using the water displacement method, Archimedes’ principle (Bruce et al ., 2022; Hughes, 2005), as showed in Fig.”
Gupta, D., Chandra, A., Patil, J. M., et al. (2026) · Frontiers in Acoustics · doi:10.3389/facou.2026.1920457
Santoso, P. H., Nurlina, N., & Mutmainna, M. (2026) · Physics Education · doi:10.1088/1361-6552/aeab3f
“…measurement, learn, problem, laboratory, determine, science, current, work, make, force, motion, system, test, value, phenomenon, project, effect (Hughes 2005) Topic 2 Energy and light experiments (ELE) , experimental, energy, light, time, university, science, course, work, different, make,…”
Metadata
- Authors
- Hughes, S. W.
- Affiliations
- Queensland University of Technology (AU)
- Corresponding author
- Hughes, Stephen W
- ORCID
- Hughes, Stephen W
- Venue
- Physics Education
- Publisher
- IOP Publishing
- Published
- 2005-09-01
- Volume
- 40
- Issue
- 5
- Pages
- 468-474
- ISSN
- 0031-9120 (ISSN-L)
- 1361-6552
- OpenAlex
- W2024090057
- Cited by
- 278
- References
- 2
- Citations by year
- 2026: 26 · 2025: 16 · 2024: 18 · 2023: 24 · 2022: 29 · 2021: 26 · 2020: 26 · 2019: 23 · 2018: 8 · 2017: 7 · 2016: 14 · 2015: 14 · 2014: 9 · 2013: 17 · 2012: 10
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physics Education (publishedVersion)
- QUT ePrints (Queensland University of Technology) (submittedVersion)
- Topics
- Social Sciences › Education › Experimental and Theoretical Physics Studies
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Education › Various Chemistry Research Topics
- Keywords
- Archimedes' principle, hydrostatic weighing, volume measurement, small objects, suspension method, water displacement, electronic scale, measurement accuracy, measurement precision, reproducibility
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review