Physical performance of a positron tomograph for brain imaging with retractable septa
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Performance characteristics of a new design of positron tomograph with automatically retractable septa for brain imaging have been studied. The device, consisting of block BGO detectors (8 x 8 elements per block), has a ring diameter of 76 cm and an axial FOV of 106.5 mm. The in-plane resolution is on average 5.8 mm and 5.0 mm (FWHM) for stationary and wobble sampling, respectively, over the central 18 cm of the transaxial FOV. Its unique feature is the capability of data acquisition both in the 'conventional' 2D mode (with septa) or 3D mode (septa retracted) where coincidences between any of the 16 detector rings are acquired. When scattered events are subtracted, the efficiency for a 20 cm diameter uniform cylinder increases overall by a factor of 4.8 between 2D (septa extended) and 3D modes. For a 20 cm phantom the trues/singles ratio is higher for 3D than for 2D but for a given unscattered trues rate, the randoms rate in 3D is higher. At 380 keV the scatter fraction within a 20 cm cylinder is 10% (septa extended) and 36% (retracted). In spite of the increase in scatter when septa are retracted, the increased efficiency in the 3D mode of acquisition yields distinct advantages, particularly in the many studies where tracer concentration is low and consequently where dead time and random rates are less important.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical performance of the latest generation of commercial positron scanner
Spinks, T. J., Jones, T., Gilardi, M. C., & Heather, J. D. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12819 · Cited by 287
Self-citationFully three-dimensional reconstruction for a PET camera with retractable septa
Townsend, D. W., Geissbuhler, A., Defrise, M., Hoffman, E. J., Spinks, T. J., Bailey, D. L., Gilardi, M.-C., & Jones, T. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108584 · Cited by 193
Self-citation3D PET using a Conventional Multislice Tomograph without Septa
Cherry, S. R., Dahlbom, M., & Hoffman, E. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00023 · Cited by 182
A method for measuring the absolute sensitivity of positron emission tomographic scanners
Bailey, D. L., Jones, T., & Spinks, T. J. (1991) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf02258426 · Cited by 136
Self-citationA positron tomograph with 600 BGO crystals and 2.6 mm resolution
Derenzo, S. E., Huesman, R. H., Cahoon, J. L., Geyer, A., Moses, W. W., Uber, D. C., Vuletich, T., & Budinger, T. F. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12807 · Cited by 108
Noise equivalent count measurements in a neuro-PET scanner with retractable septa
Bailey, D. L., Jones, T., Spinks, T. J., Gilardi, M. C., & Townsend, D. W. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97573 · Cited by 101
Self-citationPhysical characteristics of the ECAT 953B/31: a new high resolution brain positron tomograph
Mazoyer, B. M., Trébossen, R., Deutch, R., Casey, M., & Blohm, K. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108583 · Cited by 69
Self-citationAspects of three dimensional reconstruction for a multi ring positron tomography
Townsend, D. W., Spinks, T. J., Jones, T., Geissb�hler, A., Defrise, M., Gilardi, M. C., & Heather, J. D. (1989) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00631768 · Cited by 24
Self-citation
Cited by
A default mode of brain function
Raichle, M. E., MacLeod, A. M., Snyder, A. Z., Powers, W. J., Gusnard, D. A., & Shulman, G. L. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.2.676 · Cited by 12,190
Statistical parametric maps in functional imaging: A general linear approach
Friston, K. J., Holmes, A. P., Worsley, K. J., Poline, J. ‐., Frith, C. D., & Frackowiak, R. S. J. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020402 · Cited by 9,688
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 4,028
Functional and effective connectivity in neuroimaging: a synthesis
Friston, K. J. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020107 · Cited by 2,452
The neural correlates of the verbal component of working memory
Paulesu, E., Frith, C. D., & Frackowiak, R. S. J. (1993) · Nature · doi:10.1038/362342a0 · Cited by 2,230
Metadata
- Authors
- Spinks, T. J., Jones, T., Bailey, D. L., Townsend, D. W., Grootoonk, S., Bloomfield, P. M., Gilardi, M. C., Casey, M. E., Sipe, B., & Reed, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1992-08-01
- Volume
- 37
- Issue
- 8
- Pages
- 1637-1655
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2019598372
- Cited by
- 293
- References
- 8
- FWCI
- 20.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.