A convolution-subtraction scatter correction method for 3D PET
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
3D acquisition and reconstruction in positron emission tomography (PET) produce data with improved signal-to-noise ratios compared with conventional 2D slice-oriented methods. However, the sensitivity increase is accompanied by an increase in the number of scattered photons and random coincidences detected. This paper presents a scatter correction technique for 3D PET data where an estimate of the scattered photon distribution is subtracted from the data before reconstruction. The scatter distribution is estimated by iteratively convolving the photopeak projections with a mono-exponential kernel. The method accounts for the 3D acquisition geometry and nature of scatter by performing the scatter estimation on 2D projections. The assumptions of the method have been investigated by measuring the variation in the scatter fraction and the scatter function at different positions in a cylinder. Both parameters were found to vary by up to 50% from the centre to the edge of a large water-filled cylinder. Despite this, in a uniform cylinder containing water with different concentrations of radioactivity, scatter was reduced from 25% in a non-radioactive region to less than 5% using the convolution-subtraction method. In addition, the relative concentration of a cylinder containing an increased concentration, which was underestimated by almost 50% without scatter correction, was within 5% of the true concentration after correction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Improved SPECT quantification using compensation for scattered photons.
Jaszczak, R. J., Kl, G., Floyd, C. E., Harris, C. C., & Coleman, R. E. (1984) · PubMed · Cited by 555
Bergström, M., Eriksson, L., Bohm, C., Blomqvist, G., & Litton, J. (1983) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198302000-00008 · Cited by 388
Physical performance of a positron tomograph for brain imaging with retractable septa
Spinks, T. J., Jones, T., Bailey, D. L., Townsend, D. W., Grootoonk, S., Bloomfield, P. M., Gilardi, M. C., Casey, M. E., Sipe, B., & Reed, J. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/8/002 · Cited by 293
Self-citationA transmission-dependent method for scatter correction in SPECT.
Meikle, S. R., Hutton, B. F., & Bailey, D. L. (1994) · PubMed · Cited by 183
Self-citation3D PET using a Conventional Multislice Tomograph without Septa
Cherry, S. R., Dahlbom, M., & Hoffman, E. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00023 · Cited by 182
A method for measuring the absolute sensitivity of positron emission tomographic scanners
Bailey, D. L., Jones, T., & Spinks, T. J. (1991) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf02258426 · Cited by 136
Self-citationThe buildup factor: effect of scatter on absolute volume determination.
Siegel, J. A., Wu, R. K., & Maurer, A. H. (1985) · PubMed · Cited by 49
Cited by
Parametric Imaging of Ligand-Receptor Binding in PET Using a Simplified Reference Region Model
Gunn, R. N., Lammertsma, A. A., Hume, S. P., & Cunningham, V. J. (1997) · NeuroImage · doi:10.1006/nimg.1997.0303 · Cited by 1,084
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Model-based scatter correction for fully 3D PET
Ollinger, J. M. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/012 · Cited by 393
A Single Scatter Simulation Technique for Scatter Correction in 3D PET
Watson, C. C., Newport, D., & Casey, M. E. (1996) · Computational Imaging and Vision · doi:10.1007/978-94-015-8749-5_18 · Cited by 333
History and future technical innovation in positron emission tomography
Jones, T., & Townsend, D. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011013 · Cited by 303
Rakshi, J. S., Uema, T., Ito, K., Bailey, D. L., Morrish, P. K., Ashburner, J., Dagher, A., Jenkins, I. H., Friston, K. J., & Brooks, D. J. (1999) · Brain · doi:10.1093/brain/122.9.1637 · Cited by 270
Self-citationPositron Emission Tomography Partial Volume Correction: Estimation and Algorithms
Aston, J. A. D., Cunningham, V. J., Asselin, M.-C., Hammers, A., Evans, A. C., & Gunn, R. N. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200208000-00014 · Cited by 180
The design and physical characteristics of a small animal positron emission tomograph
Bloomfield, P. M., Rajeswaran, S., Spinks, T. J., Hume, S. P., Myers, R., Ashworth, S., Clifford, K. M., Jones, W. F., Byars, L. G., Young, J., et al. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/6/010 · Cited by 164
Metadata
- Authors
- Bailey, D. L., & Meikle, S. R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1994-03-01
- Volume
- 39
- Issue
- 3
- Pages
- 411-424
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2084340599
- Cited by
- 228
- References
- 7
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.