In vitro double-integrating-sphere optical properties of tissues between 630 and 1064 nm
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The optical properties (absorption and scattering coefficients and the scattering anisotropy factor) were measured in vitro for cartilage, liver, lung, muscle, myocardium, skin, and tumour (colon adenocarcinoma CC 531) at 630, 632.8, 790, 850 and 1064 nm. Rabbits, rats, piglets, goats, and dogs were used to obtain the tissues. A double-integrating-sphere setup with an intervening sample was used to determine the reflectance, and the diffuse and collimated transmittances of the sample. The inverse adding-doubling algorithm was used to determine the optical properties from the measurements. The overall results were comparable to those available in the literature, although only limited data are available at 790-850 nm. The results were reproducible for a specific sample at a specific wavelength. However, when comparing the results of different samples of the same tissue or different lasers with approximately the same wavelength (e.g. argon dye laser at 630 nm and HeNe laser at 632.8 nm) variations are large. We believe these variations in optical properties should be explained by biological variations of the tissues. In conclusion, we report on an extensive set of in vitro absorption and scattering properties of tissues measured with the same equipment and software, and by the same group. Although the accuracy of the method requires further improvement, it is highly likely that the other existing data in the literature have a similar level of accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chandrasekhar, S. (1950) · CERN Document Server (European Organization for Nuclear Research) · Cited by 8,702
Diffuse radiation in the Galaxy
Henyey, L. C., & Greenstein, J. L. (1941) · The Astrophysical Journal · doi:10.1086/144246 · Cited by 2,913 · cited 1×
“For tissues, this latter function is often represented by the Henyey–Greenstein relation which requires only one additional parameter, the scattering anisotropy factor, g (Henyey and Greenstein 1941, Flock et al 1987, Jacques et al 1987).”
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 2×
“Our list supplements the extensive list by Cheong et al (1990).”
Determining the optical properties of turbid media by using the adding–doubling method
Prahl, S. A., van Gemert, M. J. C., & Welch, A. J. (1993) · Applied Optics · doi:10.1364/ao.32.000559 · Cited by 931 · cited 4×
“A double-integrating-sphere setup was developed for measurement of in vitro tissue optical properties ( (cid:22) a , (cid:22) s , g ) (Beek 1993, Pickering et al 1993, Prahl et al 1993).”
InfluentialDouble-integrating-sphere system for measuring the optical properties of tissue
Pickering, J. W., Prahl, S. A., van Wieringen, N., Beek, J. F., Sterenborg, H. J. C. M., & van Gemert, M. J. C. (1993) · Applied Optics · doi:10.1364/ao.32.000399 · Cited by 461 · cited 7×
“In addition, background measurements were made (Beek 1993, Pickering et al 1993).”
InfluentialSelf-citationProfio, A. E. (1989) · Applied Optics · doi:10.1364/ao.28.002216 · Cited by 305
IN VIVO and POST MORTEM MEASUREMENTS OF THE ATTENUATION SPECTRA OF LIGHT IN MAMMALIAN TISSUES
Wilson, B. C., Jeeves, W. P., & Lowe, D. M. (1985) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1985.tb01554.x · Cited by 229
Extinction and absorption coefficients and scattering phase functions of human tissues in vitro
Marchesini, R., Bertoni, A., Andreola, S., Melloni, E., & Sichirollo, A. E. (1989) · Applied Optics · doi:10.1364/ao.28.002318 · Cited by 225
Flock, S. T., Wilson, B. C., & Patterson, M. S. (1987) · Medical Physics · doi:10.1118/1.596010 · Cited by 212
Effect of photosensitizer concentration in tissue on the penetration depth of photoactivating light
Wilson, B. C., Patterson, M. S., & Burns, D. M. (1986) · Lasers in Medical Science · doi:10.1007/bf02032418 · Cited by 147
Cited by
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
The physics, biophysics and technology of photodynamic therapy
Wilson, B. C., & Patterson, M. S. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/9/r01 · Cited by 1,006
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Alexandrakis, G., Rannou, F. R., & Chatziioannou, A. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/021 · Cited by 465
Hawrysz, D. J., & Sevick-Muraca, E. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900118 · Cited by 340
Jarvis, C. R., Lilge, L., Vipond, G. J., & Andrew, R. D. (1999) · NeuroImage · doi:10.1006/nimg.1999.0473 · Cited by 58
Metadata
- Authors
- Beek, J. F., Blokland, P., Posthumus, P., Aalders, M., Pickering, J. W., Sterenborg, H. J. C. M., & Gemert, M. J. C. V.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1997-11-01
- Volume
- 42
- Issue
- 11
- Pages
- 2255-2261
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1983939304
- Cited by
- 162
- References
- 19
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.