Review of photon interaction cross section data in the medical and biological context
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
The probability of a photon (x-ray, gamma-ray, bremsstrahlung, etc) of a given energy E undergoing absorption or scattering when traversing a layer of material Z can be expressed quantitatively in terms of a linear attenuation coefficient mu (cm(-1)). Since mu is dependent on the material's density, rho (g cm(-3)), which can be variable, the quantity usually tabulated is the mass attenuation coefficient mu/rho (cm2 g(-1)) in which the dependence on the density has been removed. Mu/rho, in turn, can be obtained as the sum of the different types of possible interactions of photons with atoms of the material. For photon energies below 1 MeV the major interaction processes to be considered are incoherent (Compton) scattering, coherent (Rayleigh) scattering and atomic photoeffect absorption. Above 1 MeV one must also include nuclear-field pair production and atomic-field (triplet) production, and above 5 MeV one in principle should include photonuclear absorption, although the latter is neglected in data tabulations up to the present time. This review includes a selective history of measurements and theory relating to mu/rho from the turn of the century up to the present time, and is intended to provide a basis for further calculations and critical tabulations of photon cross section data, particularly as required by users in radiation medicine and biology. The mass energy-absorption coefficient mu(en)/rho is also briefly discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Henke, B. L., Gullikson, E. M., & Davis, J. C. (1993) · Atomic Data and Nuclear Data Tables · doi:10.1006/adnd.1993.1013 · Cited by 6,285
X-ray scattering factors computed from numerical Hartree–Fock wave functions
Cromer, D. T., & Mann, J. B. (1968) · Acta Crystallographica Section A · doi:10.1107/s0567739468000550 · Cited by 3,451
The calculation of atomic fields
Thomas, L. H. (1927) · Mathematical Proceedings of the Cambridge Philosophical Society · doi:10.1017/s0305004100011683 · Cited by 2,602
Hubbell, J. H., & Seltzer, S. M. (1995) · doi:10.6028/nist.ir.5632 · Cited by 2,033
Self-citationRelativistic Hartree–Fock X-ray and electron scattering factors
Doyle, P. A., & Turner, P. S. (1968) · Acta Crystallographica Section A · doi:10.1107/s0567739468000756 · Cited by 1,927
Evans, R. D., & Beiser, A. (1955) · Cited by 1,814
Atomic form factors, incoherent scattering functions, and photon scattering cross sections
Hubbell, J. H., Veigele, W. J., Briggs, E. A., Brown, R. T., Cromer, D. T., & Howerton, R. J. (1975) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555523 · Cited by 1,792
Self-citationPhoton cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100
Storm, L., & Israel, H. I. (1970) · Atomic Data and Nuclear Data Tables · doi:10.1016/s0092-640x(70)80017-1 · Cited by 1,539
Photon mass attenuation and energy-absorption coefficients
Hubbell, J. H. (1982) · The International Journal of Applied Radiation and Isotopes · doi:10.1016/0020-708x(82)90248-4 · Cited by 1,459
Self-citationKlein, O., & Nishina, Y. (1929) · Zeitschrift für Physik · doi:10.1007/bf01366453 · Cited by 1,445
Cited by
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Grabolle, M., Haumann, M., Müller, C., Liebisch, P., & Dau, H. (2006) · Journal of Biological Chemistry · doi:10.1074/jbc.m509724200 · Cited by 188
Photon interaction and energy absorption in glass: A transparent gamma ray shield
Manohara, S. R., Hanagodimath, S. M., & Gerward, L. (2009) · Journal of Nuclear Materials · doi:10.1016/j.jnucmat.2009.07.001 · Cited by 180
Advances in kilovoltage x-ray beam dosimetry
Hill, R., Healy, B., Holloway, L., Kuncic, Z., Thwaites, D., & Baldock, C. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/6/r183 · Cited by 176
X-Ray Luminescence Computed Tomography via Selective Excitation: A Feasibility Study
Pratx, G., Carpenter, C. M., Sun, C., & Xing, L. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2055883 · Cited by 170
“Let us consider a sample consisting of a homogeneous material, described by its X-ray linear attenuation and energy absorption coefficients and , respectively [22], where is the spatial coordinate and the X-ray energy, and by optical absorption and scattering coefficients.”
BackgroundMethodInfluentialPET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients
Berthelsen, A. K., Holm, S., Loft, A., Klausen, T. L., Andersen, F., & Højgaard, L. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1784-1 · Cited by 151
Metadata
- Authors
- Hubbell, J. H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 44
- Issue
- 1
- Pages
- R1-R22
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2001027944
- Cited by
- 444
- References
- 37
- FWCI
- 8.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.