The determination of in vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy
Open accessAbstract
A method is described for measuring optical properties and deriving chromophore concentrations from diffuse reflection measurements at the surface of a turbid medium. The method uses a diffusion approximation model for the diffuse reflectance, in combination with models for the absorption and scattering coefficients. An optical fibre-based set-up, capable of measuring nine spectra from 400 to 1050 nm simultaneously, is used to test the method experimentally. Results of the analyses of phantom and in vivo measurements are presented. These demonstrate that in the wavelength range from 600 to 900 nm, tissue scattering can be described as a simple power dependence of the wavelength and that the tissue absorption can be accurately described by the addition of water, oxy- and deoxyhaemoglobin absorption.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Both Doornbos et al. and Meglinski and Matcher present optical coefficients for FST I-II skin.
“Both of these publications present optical coefficients for FST I–II skin.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [38]
Publications by Doornbos et al. and Meglinski and Matcher were the most cited with 673 and 544 citations, respectively.
“Publications by Doornbos et al.38 and Meglinski and Matcher43 were the most cited with 673 and 544 citations, respectively.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [38]
In Doornbos et al., at 630 nm absorption was greatest in the forehead compared to the sole of the foot and the arm; at 660 nm it was greatest in the sole of the foot; at 700 nm the arm had greatest absorption.
“Wavelength measurements were limited to 630 nm, 660 nm and 700 nm and at 630 nm absorption was greatest in the forehead compared to the sole of the foot and the arm. At 660 nm it was greatest in the sole of the foot, and at 700 nm the arm had greatest absorption.”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [57]
Scattering was greatest in the forehead and least in the arm at 630, 660, and 700 nm (Doornbos et al.).
“However, scattering was greatest in the forehead and least in the arm at each of these wavelengths.”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [57]
Skin location has an important effect on absorption and scattering coefficients (Doornbos et al.).
“Like Tseng et al., skin location was shown to have an important effect on absorption and scattering coefficients by Doornbos et al. [55,57].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [57]
Measured reduced scattering coefficients have up to 10-fold variability using DRS at 700 nm, ranging from 0.184 mm-1 to 2.19 mm-1.
“Similarly, measured reduced scattering coefficients have up to 10-fold variability using DRS at this wavelength, ranging from 0.184 mm-1 to 2.19 mm-1 [55,57,60,61].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [57]
In agreement with Doornbos et al., the forehead was the location of greatest scattering amongst the subjects and the arm the least.
“In agreement with Doornbos et al., the forehead was the location of greatest scattering amongst the subjects and the arm the least [57].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [57]
Numerous authors have measured optical properties of skin on the forearm using DRS and absorption coefficients vary 9-fold amongst publications from 0.01 mm-1 to 0.09 mm-1 at 700 nm.
“Numerous authors have measured the optical properties of skin on the forearm using DRS and the absorption coefficients vary 9-fold amongst the publications from 0.01 mm-1 - 0.09 mm-1 at 700 nm [37,46,55,57,60].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [57]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 24 · Cited by 380
Research works printed but not linked: 2
- W H, Flannery B P, Teukolsky S A and Vetterling W T 1989 Numerical Recipes in Pascal, the Art of Scientific Computing (New York: Cambridge University Press)
- Wilson B C, Farrell T J and Patterson M S 1990 An optical fiber-based... Proc. SPIE IS6 219-32
- Authors
- Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M.
- Affiliations
- Amsterdam UMC Location University of Amsterdam (NL)
- Royal London Hospital (GB)
- Daniel den Hoed Kliniek (NL)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 44
- Issue
- 4
- Pages
- 967-981
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2128560962
- Cited by
- 380
- References
- 24
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 14 · 2023: 12 · 2022: 14 · 2021: 16 · 2020: 7 · 2019: 12 · 2018: 14 · 2017: 15 · 2016: 23 · 2015: 19 · 2014: 14 · 2013: 14 · 2012: 17
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
- Pure Amsterdam UMC (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Keywords
- tissue optical properties, chromophore concentration, diffuse reflectance spectroscopy, spatially resolved spectroscopy, diffusion approximation, absorption coefficient, scattering coefficient, hemoglobin absorption, water absorption, turbid media
- MeSH terms
- Humans, Skin, Spectrum Analysis, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review