Abstract
Respiration causes variations in the signals acquired during magnetic resonance imaging (MRI) and therefore is a significant source of noise in functional brain imaging. A primary component of respiratory noise may arise from variations of bulk susceptibility or air volume in the chest. Here we investigate the nature of the image artefacts that can be caused by such changes. We develop a simple model which attempts to mimic the effects of variations in susceptibility and volume during respiration. Theoretical calculations, computer simulations and imaging experiments with this model show that small variations in susceptibility within the thorax from alterations in the paramagnetism of cavity gas may lead to a shift of the image on the order of 0.1 pixels as well as a shading of the intensity by +/-1%. These effects are observed to be predominant in the phase-encoding direction. They may lead to the production of spurious activations in functional MRI and are likely to be of more importance at higher field strengths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wise, R. G., Ide, K., Poulin, M. J., & Tracey, I. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.025 · Cited by 664
“Chest position was included to account for signal changes that may arise from chest movements and respiration (Hu et al., 1995), for example, susceptibility induced B 0 -related shifts and intensity changes (Raj et al., 2000).”
BackgroundMethods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Marques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Non-white noise in fMRI: Does modelling have an impact?
Lund, T. E., Madsen, K. H., Sidaros, K., Luo, W.-L., & Nichols, T. E. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.07.005 · Cited by 414
Salomir, R., de Senneville, B. D., & Moonen, C. T. (2003) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.10083 · Cited by 389
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Raj, D., Anderson, A. W., & Gore, J. C. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/12/318 · Cited by 198
Self-citationReal‐time shimming to compensate for respiration‐induced B0 fluctuations
van Gelderen, P., de Zwart, J. A., Starewicz, P., Hinks, R. S., & Duyn, J. H. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21136 · Cited by 193
“Correction methods based on navigator echoes have been proposed (5,6), and although they do lead to some improvement, this kind of correction is generally inadequate because of the substantial spatial heterogeneity of the induced field changes (3,4,7).”
MethodChallenges and opportunities for brainstem neuroimaging with ultrahigh field MRI
Sclocco, R., Beissner, F., Bianciardi, M., Polimeni, J. R., & Napadow, V. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.052 · Cited by 163
“These effects decrease with the cube of the distance from the center of the lungs (Raj et al. 2000), implying that inferior regions of the brain, such as the brainstem, suffer from higher signal instability and artifacts related to chest motion than other brain regions (see also Figure 3).”
Svedin, B. T., Payne, A., & Parker, D. L. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25860 · Cited by 30
Metadata
- Authors
- Raj, D., Paley, D. P., Anderson, A. W., Kennan, R. P., & Gore, J. C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-11-21
- Volume
- 45
- Issue
- 12
- Pages
- 3809-3820
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2002271924
- Cited by
- 116
- References
- 0
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.