The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Respiratory effects in human functional magnetic resonance imaging due to bulk susceptibility changes
Abstract
Functional magnetic resonance imaging relies on detecting small changes in the signal in the presence of noise from various sources. It has been shown that periodic variations in the signal at the respiratory frequency occur in the brain and various techniques have been proposed to remove them. However, the precise mechanism by which respiration affects the fMRI signal has not yet been proven. Here, we explore the nature of respiratory signal variations and the artefacts they produce in brain images. Our results demonstrate conclusively that bulk susceptibility variations in the lungs during respiration cause variations in the static magnetic field within the brain tissue. These variations in field strength and homogeneity lead to a shift of the image and a shading of image intensity in the phase encoding direction. These artefacts, if left uncorrected, may lead to the production of spurious activations and/or decreased statistical significance of true activations in fMRI. In addition, these results suggest that respiration effects may not necessarily be well characterized as simple additive noise and that an alternative model based on the physical origins of susceptibility variations may be more appropriate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
Cited by
Brain connectivity related to working memory performance
Hampson, M., Driesen, N. R., Skudlarski, P., Gore, J. C., & Constable, R. T. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.3408-06.2006 · Cited by 853
Self-citationResting-state fMRI confounds and cleanup
Murphy, K., Birn, R. M., & Bandettini, P. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.001 · Cited by 666
Birn, R. M., Smith, M. A., Jones, T. B., & Bandettini, P. A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.059 · Cited by 645
Building a Science of Individual Differences from fMRI
Dubois, J., & Adolphs, R. (2016) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2016.03.014 · Cited by 628
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Metadata
- Authors
- Raj, D., Anderson, A. W., & Gore, J. C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-11-14
- Volume
- 46
- Issue
- 12
- Pages
- 3331-3340
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2021260330
- Cited by
- 198
- References
- 1
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Respiratory effects in human functional magnetic resonance imaging due to bulk susceptibility changes. https://app.cochat.ai/papers/10.1088/0031-9155/46/12/318
- The paper
- Raj, D., Anderson, A. W., & Gore, J. C. (2001). Respiratory effects in human functional magnetic resonance imaging due to bulk susceptibility changes. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/46/12/318
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.