Investigation of a large-area phased array for focused ultrasound surgery through the skull
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Non-invasive treatment of brain disorders using ultrasound would require a transducer array that can propagate ultrasound through the skull and still produce sufficient acoustic pressure at a specific location within the brain. Additionally, the array must not cause excessive heating near the skull or in other regions of the brain. A hemisphere-shaped transducer is proposed which disperses the ultrasound over a large region of the skull. The large surface area covered allows maximum ultrasound gain while minimizing undesired heating. To test the feasibility of the transducer two virtual arrays are simulated by superposition of multiple measurements from an 11-element and a 40-element spherically concave test array. Each array is focused through an ex vivo human skull at four separate locations around the skull surface. The resultant ultrasound field is calculated by combining measurements taken with a polyvinylidene difluoride needle hydrophone providing the fields from a 44-element and a 160-element virtual array covering 88% and 33% of a hemisphere respectively. Measurements are repeated after the phase of each array element is adjusted to maximize the constructive interference at the transducer's geometric focus. An investigation of mechanical and electronic beam steering through the skull is also performed with the 160-element virtual array, phasing it such that the focus of the transducer is located 14 mm from the geometric centre. Results indicate the feasibility of focusing and beam steering through the skull using an array spread over a large surface area. Further, it is demonstrated that beam steering through the skull is plausible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Demonstration of Potential Noninvasive Ultrasound Brain Therapy Through an Intact Skull
Hynynen, K., & Jolesz, F. A. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00269-x · Cited by 446 · cited 2×
“Experimental studies (Hynynen and Jolesz 1998) have shown that it is possible to reconstruct the focus inside an ex vivo human skull by manual adjustment of a transducer array's driving phases.”
Self-citationter Haar, G. (1999) · European Journal of Ultrasound · doi:10.1016/s0929-8266(99)00013-0 · Cited by 327
Ultrasonic absorption and attenuation in mammalian tissues
Goss, S. A., Frizzell, L. A., & Dunn, F. (1979) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(79)90086-3 · Cited by 313
Thomas, J.-L., & Fink, M. A. (1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.542055 · Cited by 312 · cited 1×
“Advances in transducer array technology have prompted proposals for both mildly invasive (Thomas and Fink 1996) and non-invasive techniques (Sun and Hynynen 1999).”
MR temperature mapping of focused ultrasound surgery
Cline, H. E., Hynynen, K., Hardy, C. J., Watkins, R. D., Schenck, J. F., & Jolesz, F. A. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310608 · Cited by 260
Self-citationVykhodtseva, N. I., Hynynen, K., & Damianou, C. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)00038-s · Cited by 230
Self-citationSun, J., & Hynynen, K. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426863 · Cited by 139 · cited 2×
“Advances in transducer array technology have prompted proposals for both mildly invasive (Thomas and Fink 1996) and non-invasive techniques (Sun and Hynynen 1999).”
Self-citation
Cited by
A Randomized Trial of Focused Ultrasound Thalamotomy for Essential Tremor
Elias, W. J., Lipsman, N., Ondo, W. G., Ghanouni, P., Kim, Y. G., Lee, W., Schwartz, M., Hynynen, K., Lozano, A. M., Shah, B. B., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1600159 · Cited by 1,167
“Headache lasting >1 day 8 (14) 8 4 4 2 2 4 (20)”
Self-citationA Pilot Study of Focused Ultrasound Thalamotomy for Essential Tremor
Elias, W. J., Huss, D., Voss, T., Loomba, J., Khaled, M., Zadicario, E., Frysinger, R. C., Sperling, S. A., Wylie, S., Monteith, S. J., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1300962 · Cited by 875
High intensity focused ultrasound: Physical principles and devices
ter Haar, >., & Coussios, C. (2007) · International Journal of Hyperthermia · doi:10.1080/02656730601186138 · Cited by 805
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
High intensity focused ultrasound: surgery of the future?
Kennedy, J. E., ter Haar, G. R., & Cranston, D. (2003) · The British Journal of Radiology · doi:10.1259/bjr/17150274 · Cited by 709
Metadata
- Authors
- Clement, G. T., White, J., & Hynynen, K.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-03-17
- Volume
- 45
- Issue
- 4
- Pages
- 1071-1083
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2066589402
- Cited by
- 162
- References
- 7
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.